Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
or less 40 or less 30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
Type: 4A (For DC), Lead Wire Length: 10 (1000mm)
Type: 4A (For DC), Lead Wire Length: 6 (600mm)
Type: 4A (For DC), Lead Wire Length: 20 (2000mm)
Type: 4A (For DC), Lead Wire Length: 15 (1500mm)
Type: 4A (For DC), Lead Wire Length: 50 (5000mm)
Type: 4A (For DC), Lead Wire Length: 25 (2500mm)
Polarity SOL.A 1A ( ) ( + ) SOL.B 1B ( ) ( + ) 1 station 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A ( ) ( + ) SOL.B 2B ( ) ( + ) 2 stations SOL.A 3A ( ) ( + ) SOL.B 3B ( ) ( + ) 3 stations SOL.A 4A ( ) ( + ) SOL.B 4B ( ) ( + ) 4 stations SOL.A 5A ( ) ( + ) 10A COM SOL.B 5B ( ) ( + ) 5 stations
Caution
Solenoid Valve Specifications Fluid Air 0 to 0.7 1 port: 100 kPa to 0.6/3 ports: 100 kPa to 0 1 port: 100 kPa to 0/3 ports: 100 kPa to 0.6 10 to 50 (No freezing) 20 Not required Unrestricted 150/30 Dustproof 24 VDC, 12 VDC 10% of rated voltage Note 2) Positive pressure N.C. N.O.
Response time (ms) (0.5 MPa) Type of actuation 52-SY5000 26 or less 22 or less 38 or less 52-SY7000 38 or less 30 or less 56 or less 52-SY9000 50 or less 50 or less 70 or less 2-position single 2-position double 3-position Note 1) According to dynamic performance test JIS B8375-1981. Note 2) Response time when barriers were combined with a valve.
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04