8 15 116 18 13 28 5 15 24 62 20 Up to 300 7.5 10 33.5 M10 X 1.25 19.5 17 32 6 8 25.3 37 M26 X 1.5 45 8 15 120 22 13 5.5 15 30 62 26 Up to 300 7.5 12 37.5 M10 X 1.25 19.5 17 32 6 8 27.6 M26 X 1.5 39.3 34.5 45 8 15 122 22 13 5.5 15 64 26 Up to 300 14 22 41 8 10 33.6 46.5 21 10.7 47.8 M14 X 1.5 21.5 42.5 M32 X 2 50 11 154 24 16 7 19 88 32 With rod boot h l Symbol f e 1 to 50 51 to 100 101 to
8 58 11 81 1/4 24 10 24 63 20 depth13 90 77 13 35.5 30 M27 x 3 33 9 69 13 100 1/4 27.5 10 27.5 80 23 depth 15.2 105 88 17 45 41 M30 x 3.5 36 14 86 15 121 3/8 31 15 31 100 26 depth 17.5 132 106 26 56 50 M39 x 4 45 21 106 17 146 3/8 36 15 36 Note) Body dimensions are the same with or without auto switches.
5 2.5 2-M2 x 0.4 depth 6 (Mounting thread) 4 2 2 When closed 10 When open 30 13.6 14 20 12 0.05 10 4 6 +0.022 0 7H8 depth 1.5 29 (41) M3 x 0.5 (Finger opening port) 4 -0.005 -0.025 0.8 1.3 M3 x 0.5 Finger closing port 5.5 14.3 In the case of MHCA2-6S, finger opening port is a breathing hole. 9 Angular Air Gripper Series MHC2-6/MHCA2-6 Auto Switch Mounting Auto Switch Hysteresis Strait bladed
Rc 3/8 226 410 473 67 125 304 33 36 154 21 330 13 Rc 1/2 453 498 283 275 455 270 31 42 80 240 80 15 15 Rc 3/4 485 568 355 300 300 314 41 54 87 43 101 16 603 578 396 380 Rc 1 Meaning the foot dimensions for the IDFA3E. 94 A Refrigerant R407C (HFC) IDFAE Series 22E, 37E, 55E, 75E (Inlet air temperature: 35C) HAA HAW How to Order AT IDF IDU IDFA 55E 23 Nil C G K L R T V IDF FS Note 1) Size
For dimensions of 25 stroke, refer to page 8-26-20. 12.5 15 15 10.5 12.5 15 15 10 23 23 12.5 15 12.5 15 15 17.5 15 17.5 15 17.5 15 17.5 9 17.5 14 16 22 23 23 24 22 23 23 24 Note 2) For 25 stroke, the shock absorber is mounted on a single side of the plate.
15 16 20 24 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 44 66 96 9 11 13 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AME550 AME650 AME850 1 2 1 2 1 2 1 Please refer to page 14-20-57 for Made to Order Specifications. 14-20-41
-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 21 31 20.5 13 18 58 3H9 depth 3 +0.025 0 15 9.5 4-3.2 4-6.5 4.5 4.7 2-M3 x 0.5 thread depth 6 A G H 8 4-M4 x 0.7 Operating port 2-M3 x 0.5 Section AA M 8 N 2 ( 1): The number of pitches 0.3 15 (Table length) 16 4.5 J 8 Z 2.4 Max. 9 ZZ H G 3H9 depth 3 +0.025 0 21 4 3H9 depth 3 +0.025 0 (mm) ZZ
Dimensions Grommet VQ10-G-M5 (M3) 29.2 6.1 Manual override 4.9 12.4 14.8 E 2-2.7 mounting hole 12 3.7 18.1 (Lead wire length) 300 Locking type manual override 30.7 28 11 A P (5.9) (5.9) 7 ( 4 . 1 ) 5 5 5 4.9 9.7 4.9 3-M5, (M3) (18.1) ( ): M3 Broken line: Locking type manual override 4-12-10 11 3 Port Solenoid Valve Series VQ100 Dimensions L plug connector VQ10-L-M5 (M3) 35.1 Manual override
Contact output signal 3 Output Alarm signal (N.C. type) 15 9 D-sub 15-pin female (socket) type Contact input/output signal connector 30 HRR Series For details, refer to the Operation Manual on the SMC website.
Note 3) Through-hole in case of 5 to 15 mm stroke.
Refer to p.2.9-15 for How to Order for DIN rail.
Nil S n Cylinder bore size 15 32 15mm 32mm Type of auto switch Nil Without auto switch Select auto switches from the table below.
F A L L L Guide central axis A M1 = F x L M2 = F x L M3 = F x L Note) Displacement of Section A when force acts on Section F CYP15 (M1) CYP15 (M2) CYP15 (M3) 0.05 0.05 0.05 0.04 0.04 0.04 Deflection (mm) Deflection (mm) Deflection (mm) 0.03 0.03 0.03 0.02 0.02 0.02 0.01 0.01 0.01 0.1 0.2 0.3 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0 Moment (Nm) Moment (Nm) Moment (Nm) CYP32 (M1) CYP32 (M2) CYP32 (M3)
F A L L L Guide central axis A M1 = F x L M2 = F x L M3 = F x L Note) Displacement of Section A when force acts on Section F CYP15 (M1) CYP15 (M2) CYP15 (M3) 0.05 0.05 0.05 0.04 0.04 0.04 Deflection (mm) Deflection (mm) Deflection (mm) 0.03 0.03 0.03 0.02 0.02 0.02 0.01 0.01 0.01 0.1 0.2 0.3 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0 Moment (Nm) Moment (Nm) Moment (Nm) CYP32 (M1) CYP32 (M2) CYP32 (M3)
If a socket without check valve is used, the check valve of the plug will not open. 343 KKA Series Flow Rate Characteristics Air Plug: With check valve Socket: With check valve Plug: With check valve Socket: With check valve 50 10 KKA9 Series (KKA9P-12F+KKA9S-12F) 45 9 KKA6 Series (KKA6P-04F+KKA6S-04F) 40 8 Flow rate m3/min (ANR) Flow rate m3/min (ANR) 35 7 30 6 KKA8 Series (KKA8P-10F+KKA8S
(6) 1 2-M4 x 0.7 thread length 8 P.C.D.38 2 1 2 4 45 3 41 32 2-M3 x 0.5 thread length 8 P.C.D.29 3 Low torque Metal seal type Rotary jointSeries MQR * symbol indicates flange dimensions Dimensions/Standard Type, Flange Type MQR8-M5 MQR12-M5 0.03 7 M6 x thread length 10 4-M3 x 0.5 thread length 6 P.C.D.43 4-M3 x 0.5 thread length 6 P.C.D.48 M6 x 1 thread length 10 0.03 8 4.1 0.05depth 10
10 15 20 30 Electric spec.
15 15-1 / IDF Series 15-1 15-1 B: 2021/11 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Tel: +81 3 5207 8249 Fax: +81 3 5298 5362 URL: https://www.smcworld.com Specifications are subject to change without prior notice and any obligation the part of the manufacturer. 2021 SMC Corporation All Rights Reserved
Port size 41 (12) Grommet (G) (35) (5.5) 33 (7.5) 2n-C4, C6, C8 44.5 Mounting holes 15 7.7 C4: One-touch fitting for 4 C6: One-touch fitting for 6 (2) DIN rail clamp screw C8: One-touch fitting for 8 U side n A 4 B 2 Manual override SY 5 4 P=16 23.9 (L4) (L3) P=16 SYJ L1 L2 3 2n-Rc(PT)1/8 2 P=16 20.4 SX 1 SMC A 4 16.9 18 A 4 B 2 B 2 Stations VK 5 D side 15 7.7 VZ 10 10 Rc(PT)1/8 53 38 VF
65 170 66 2 11 55 41 20 15 63 70 183 79 2 11 75 52 20 17.5 68 88 217 100 3 11 87 95 70 20 20 72 90 256 117 3 11 114 110 83 20 26.5 98 108 321 154 3 11 134 130 102 20 38 133 138 335 200 3 11 190 180 153 30 40 114 Note 1) Dimension E applies when heater option is included.