SMC Corporation of America
Elite Part Number Search
Search Results "S070A-VDC"

-made) Cable: 16AWG 1 1 24 VDC + Wire color Contents 2 Brown 24 VDC + Power connector Blue 24 VDC J.S.T. Mfg. Co., Ltd.

Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Max. load current 500 mA AC/DC (Resistance load) Min. load current 5 VDC 10 mA Output voltage 24 VDC 10% 200 mA MAX (No inductive load) Contact output signal Product side Customer system side 1 Contact input signal COM 1 k 2 Contact input

VK300-82-2-01 VK300-82-2-03 110 VAC 110V VK300-82-2-02 200 VAC 200V VK300-82-2-04 220 VAC 220V DIN terminal type VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD Indicator light (Built-in connector) Marking Circuit with indicator light AC circuit diagram 12 VDC or less circuit diagram 24 VDC or more circuit diagram

VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 A1 A2 A3 LW06 LW2 LD4 LD8 100 VAC 200 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC 4-13-3 4 For details about the applicable products conforming to international standards, visit us at www.smcworld.com. 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry

Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (with power drop warning at approx. 20 V) Power supply voltage range Communication power supply for DeviceNet 11 to 25 VDC 200 mA or less (single GW unit) Current consumption Communication power supply for DeviceNet 50 mA or less Input Unit Manifold Number of inputs/outputs Maximum 64 inputs/64

Electrical entry direction Perpendicular Perpendicular Perpendicular 3-wire Wiring type 2-wire Output type NPN PNP IC circuit, 24 VDC relay, PLC Applicable load 24 VDC relay, PLC 5, 12, 24 VDC (4.5 to 28 VDC) Power supply voltage 10 mA or less Current consumption Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA 80 mA or less 1.5 V or less (0.8

Step 3 Item Selection item Symbol A Voltage 24 VDC VDW 1 0 A Select electric specifications. A Electrical entry Grommet For other special options, refer to page 462. Step 4 455 A VDW Series Single Unit For Air Model/Valve Specifications N.C.

Voltage AC and 100 VDC 24 VDC or less Terminal no. 1 + () With indicator light With indicator light Terminal no. 1 (+) F.R.L.

) 100 or less (at 12 VDC) Brown LINE(+) Brown DC(+) Load Main circuit Main circuit (Analog output) 1 k Black OUT 12 to 24 VDC + 12 to 24 VDC + Load Blue LINE() Blue DC() Load Install the load either on the LINE (+) or LINE () side.

(ZSM1-115) to 100 VDC to 100 VAC 24 to 125 VDC 100 to 250 VAC 24 to 220 VDC 100 to 550 VAC Voltage 100 VAC/DC or less (ZSM1-121) Repeatability 0.05 MPa 0.05 MPa 3% F .S. 3% F.S. 3% F.S. 3% F.S. 10% F.S. 15 kPa or less (ZSM1-115) 0.02 to 0.35 MPa (Without pointer scale) 0.03 to 0.4 MPa (Without pointer scale) Hysteresis (Calibration range of ISG) 0.08 MPa or less 0.01 to 0.2 MPa 7 to 53 kPa

on NVS 3125) 48 VDC Poitlng 01 = 1/8" NPTF (NVS 3125 only) Cv 069 02 = 1/4' NPTF (NVS 3125 only) Cv 0.8i!

N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.

, 24 VDC 10% of rated voltage Equivalent to Class B 1 W DC (42 mA) 1 W DC (83 mA) 1 (P) 5 (R1) 3 (R2) Power consumption (Current) 24 VDC 12 VDC 2-position double (Rubber) Note 1) Use dry air to prevent condensation at low temperatures.

OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC FUNC FUNC U Blue DC () Blue DC () -E PNP (1 output) + Analog voltage output -F PNP (1 output) + Analog current output Brown DC (+) Brown DC (+) Black OUT1 Black OUT1 + + White OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC Load Load FUNC FUNC U Blue DC () Blue DC () The FUNC terminal is connected when using the copy function.

Electrical entry of 2 port solenoid valve D : DIN connector DL: DIN connector (With indicator light) T : Conduit terminal TL: Conduit terminal (With indicator light) D0: DIN connector (Without connector) Voltage of 2 port solenoid valve 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC 866 A Air Catch Sensor Series ISA2 RoHS How to Order For single and double notation type

Maximum load current 500 mA AC/DC (Resistance load) Contact output signal 1, 2, 3 Minimum load current 5 VDC 10 mA 24 VDC Output voltage 24 VDC 10% 500 mA MAX1 (No inductive load) 1 When using the power supply of this product, make sure that the total load current is 500 mA or less. Contact Input/Output Pin Nos. Pin no.

Table 10-1 specifications EX245-FPS1 EX245-FPS2 EX245-FPS3 (W x L x H) mm 85 x 148.5 x 136 1,100 g 1,200 g 8 128 () 64 (US1) 350 mA 300 mA (US1/US2) XD1/XD2 16 A (US1/US2) 10 A (US1/US2) 24 VDC +20%/-15% <20.4 VDC US1 >21.6 VDC < 17 VDC 6 A 24 VDC +20%/-15% <21.6 VDC : >22.8 VDC US2 / <17 VDC 4 A () 1.2 V US1 US2 4 8 US1 UT1/UT2 24 VDC +20%/-15% 2 A( UT1) 1 A (

light TS Conduit terminal with surge voltage suppressor TZ Conduit terminal with light/surge voltage suppressor DL DIN terminal with indicator light DS DIN terminal with surge voltage suppressor DZ DIN terminal with light/surge voltage suppressor 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Made to Order Specifications (For details, refer to page 4-10-8.)

12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.