SMC Corporation of America
Elite Part Number Search
Search Results "RZQL32-200-160"

-75kPa -80kPa -85kPa 100 Pad diameter (mm) 80 63 50 40 10 30 50 70 100 200 5 7 Lifting force (N) How to read Example: Work load 20 kg (Lifting force: 196 N) Conditions:Desired number of pads 5 pcs.

JA80-20-250 JA100-24-300 JA100-27-150 JA125-27-200 JA160-33-200 20 25 32 32, 40 40 32, 40 50 50, 63 80 100 100 125 160 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 M20 x 2.5 M24 x 3 M27 x 1.5 M27 x 2 M33 x 2 1100 2500 2500 4400 4400 4400 11000 11000 18000 28000 28000 28000 71000 1100 2500 2500 4400 4400 4400 11000 11000 18000 28000 28000 28000 55000 1000 2000

Tie-rod Type Hydraulic Cylinder Double Acting/Single Rod CHA Series 40, 50, 63, 80, 100, 125, 160 3.5 MPa How to Order Bore size 40 50 63 80 100 125 160 Cylinder options 40 mm 50 mm 63 mm 80 mm 100 mm 125 mm 160 mm Nil J K Nil N R H Without rod boot Nylon tarpaulin Neoprene cloth Both sides Without cushion With rod cushion With head cushion Aluminum tube Steel tube Rod boot Tube material

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.30 0.35 0.6 0.7 Outlet pressure MPa Outlet pressure MPa 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure

YLINDER SIZING Y L I N D E R F O R C E heoretlcel Force Linear cylinders have the following standard diameters as rcommended in ISO: 8, 10, 12, 16,20,25,32,40, 50, 63, 80, 100, 125, 140, 160, 200, 250, 320 mm The force developed by a cylinder is a function of the piston diameter, the operating air pressure and the resistance.

180 200 124 Double r c d c02w 160 200 Long stroke 32 40 50,63 a0,100 r c d (N)CO2 Anti-lateral load Serbs with wL-.. tiIE_" a2O lo a1 Provides drop tn one sysrem a a a o a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a e o @ o @ o , o . 9 @ 1 1 ) . o @ Os*i"" Metric rod threads & PT ports inch rod threads & NPT oorts DMounting

YLINDER SIZING Y L I N D E R F O R C E heoretlcel Force Linear cylinders have the following standard diameters as rcommended in ISO: 8, 10, 12, 16,20,25,32,40, 50, 63, 80, 100, 125, 140, 160, 200, 250, 320 mm The force developed by a cylinder is a function of the piston diameter, the operating air pressure and the resistance.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.30 0.35 0.6 0.7 Outlet pressure MPa Outlet pressure MPa 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure

100 108 R2.5 M16 x 2 42 9 174 140 45 38 36 22 28 17 38 M33 x 2 40 3/4 94 159 12 43 36 (mm) Bore size (mm) Z ZZ TT TX TY TZ V W 40 123 246 24 70 65 95 7.5 8 50 131 262 26 83 78 108 10 9 63 140 280 26 90 86 115 12 10 80 156 312 36 112 106 162 16 13 100 170 340 42 140 130 204 20 16 125 170 340 42 170 162 234 20 16 160 187.5 375 52 212 200 284 24 20 111 Tie-rod Type Low Pressure Hydraulic Cylinder

(Displays 0 when the value is below 70 L/min) 160 to 2100 L/min 80 to 1050 L/min (Displays 0 when the value is below 160 L/min) 8.0 0 to 8%F.S. (Displays 0 when the value is below 80 L/min) 180 to 2100 L/min 90 to 1050 L/min (Displays 0 when the value is below 180 L/min) 9.0 0 to 9%F.S.

44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 25 38 80 60 MGP 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 32 46 95 70 75, 100 125, 150 200, 250 300 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 32 50 105 80 MGQ 70 40 160 37 M8 165 85 12 9 125 110 176 160 16 18 107 38 60 125 95 45 194 42 M10 200 95 12 11 135 115 210 190 82.5 19 23 142 50 75 150 115 MGG Bore (mm) Z Y X W

Use pilot ports and sensor (breathing) ports as indicated below. (2) Lead wire color Rated voltage (1) (2) DC (Type B only) Red Black 100 VAC Blue Blue Sensor (breathing) port PB port PA Port 200 VAC Red Red N.C. Exhaust Exhaust Pressure Other AC Gray Gray N.O. Exhaust Pressure Exhaust There is no polarity.

AN200 to 900 1 Model 0.5 A B D Dimensions (mm) Model Port size R Weight (g) Recommended flow (m3/min (ANR)) 3 or less 5 or less 8 or less 12 or less 20 or less 30 or less 50 or less 80 or less Effective area (mm2) 35 60 90 160 270 440 590 960 2 0.2 Inlet pressure (MPa) Noise level (dB) (A) 0.1 1 4 AN200-02 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233

Note 7) Note 7) Stroke standard (pneumatic) Long stroke 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 Bore 12 16 20 25 32 40 50 63 80 100 125 140 160 180 200 Note 7) Only CQ2 is available with 180 and 200 bores. Note 7) Note 7) Standard stroke 2

-35D -35D -35D 8.5 15.5 16.5 x 110 L x 125 L x 150 L x 100 L 100 110 125 150 -40D -40D -40D -40D -X x 115 L x 130 L x 155 L x 105 L 105 115 130 155 -45D -45D -45D -45D x 120 L x 135 L x 160 L x 110 L 110 120 135 160 Individual -X -50D -50D -50D -50D x 125 L x 140 L x 165 L x 115 L 115 125 140 165 -75D -75D -75D x 150 L x 165 L x 190 L 150 165 190 -100D -100D -100D x 175 L x 190 L x 215 L

180 200 0 0 20 40 60 80 100 120 140 160 180 200 Temperature (C) Temperature (C) 942 LQ1/LQ3/LVN/LQHB Series Applicable Fluids Material and fluid compatibility check list for high purity fluoropolymer fittings Chemical Compatibility LVC Acetic acid 100% LVA Acetone 100% Note 1,2) LVH Ammonium fluoride 40% Ammonium hydroxide 30% LVD Butyl acetate 100% LVQ Methylne chloride 100% LVP

XMA series with KF (NW) flange A (mm) Model Weight (kg) Conductance (L/s) B (mm) CYV XMA-16 40 103 0.33 5 XMA-25 XMA-40 XMA-50 50 113 0.61 14 B 65 158 1.40 45 70 170 2.00 80 A 160 XMA-63 XMA-80 88 196 3.60 90 235 6.20 200 A : Common to all series. 479 Series Variations Operating pressure Flange size Shaft seal system Models Valve type Angle type In-line type Options Application Switch Indicator

200 140 180 Air consumption [L/min (ANR)] Air consumption [L/min (ANR)] Air consumption [L/min (ANR)] 140 120 160 120 100 140 100 120 80 100 80 60 80 60 60 40 40 40 20 20 20 0 0 0 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] ZNC60m ZNC80m 300 200 180 Air consumption [L/min (ANR)] Air consumption

CHKGL--XC63 155, 160, 165, 170 Stroke Bore size (mm) 55, 60, 65, 70 80, 85, 90, 95 105, 110, 115, 120 130, 135, 140, 145 LA B Z LA B Z LA B Z LA B Z LA B Z 32 166 131 147 191 156 172 216 181 197 241 206 222 40 183 140 160 208 165 185 233 190 210 258 215 235 283 240 260 50 196 145 169 221 170 194 246 195 219 271 220 244 296 245 269 63 215 152 182 240 177 207 265 202 232 290 227 257 315 252