FA AL B N A F N H S + Stroke FB ZZ + Stroke CJ5 CG5 (mm) Bore size A Stroke range AL B B1 C D Ee11 F FA FB G H H1 MA MB J K KA MM N P S T U V W HA ZZ HY 32 40 50 63 500 or less 22 24 32 32 18 20 27 27 50 58 70 84 17 19 24 24 32.5 38 46.5 56.5 12 16 20 20 30 35 40 45 16 18.5 23 23 5 4.5 5 5 4 4 4 4 14 15 17 17 48 54 69 69 6 7 10 10 16 16 16 16 3.2 3.2 4.2 4.2 M6 x 1 M6 x 1 M8 x 1.25 M8 x
), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200 VAC
Individual -X Technical data 293 Series MB Without Mounting Bracket Cushion valve Basic: (B) WV Port G 2 x P MM G With rod boot E E D e C B d H1 MB Effective thread 2 x 4 x J C B A K F N MA 10.2 10.2 f l N S + Stroke H h ZZ + Stroke Width across flats Stroke range (mm) Bore size (mm) Effective thread length S ZZ A C B D Ee11 F G H1 H MA MB J K MM N P V W 32 40 50 63 80 100 125 22 30 35 35
), 0.5 W DC (21 mA) 3 position exhaust center 12 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) 2 position double (Metal) (A) 4 (B) 2 (A) 4 (B) 2 100 VAC Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) Power consumption (Current) 110 VAC Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 1 (P) 5 (R1) 3 (R2) 200 VAC Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 1 (P) 5 (R1) 3 (R2) 220 VAC Inrush 2.6 VA
Find the terms of Equation (13.1) from the diagram. 5 0.1 [mA] Ig1 20 1000 5 0.1 [mA] Ig2 20 1000 Ign 0 (not used) Iga 0.1 [mA] Igm 0.1 [mA] Insert these values in Equation (13.1). Ig 10 {0.1 0 0.1 1 (0.1 0.1)} 4.0 [mA] According to the result of calculation, use a leakage current breaker having the rated sensitivity current (Ig) of 4.0[mA] or more.
Find the terms of Equation (11.1) from the diagram. 5 0.1 [mA] Ig1 20 1000 5 0.1 [mA] Ig2 20 1000 Ign 0 (not used) Iga 0.1 [mA] Igm 0.1 [mA] Insert these values in Equation (13.1). Ig 10 {0.1 0 0.1 1 (0.1 0.1)} 4.0 [mA] According to the result of calculation, use a leakage current breaker having the rated sensitivity current (Ig) of 4.0[mA] or more.
Find the terms of Equation (13.1) from the diagram. 5 0.1 [mA] Ig1 20 1000 5 0.1 [mA] Ig2 20 1000 Ign 0 (not used) Iga 0.1 [mA] Igm 0.1 [mA] Insert these values in Equation (13.1). Ig 10 {0.1 0 0.1 1 (0.1 0.1)} 4.0 [mA] According to the result of calculation, use a leakage current breaker having the rated sensitivity current (Ig) of 4.0[mA] or more.
Analog output 4-20 mA 0-10 VDC P4 Set pressure P3 P2 P1 0 1023 Digital input data Time Static Electricity Elimination Equipment Reduced-wiring Fieldbus System Digital signal Analog signal Analog signal Actuator Electro-pneumatic regulator PLC Controller Controller Actuator Electro-pneumatic regulator PWR ERR 1bit 2 bit . . . . 10 bit 010 VDC 420 mA DC 010 VDC 420 mA DC Series ITV Series ITV
/PNP output Bracket Analog output 4 to 20 mA DC (Sink type) Nil Without bracket Flat bracket Thread type Nil Rc B N F NPT G Note) Note) Complies with ISO1179-1 (2007).
A voltage drop may cause the air dryer to stop operating. *1 Select an earth leakage breaker with a sensitivity of leak current of 30 mA and a rated current of 10 A. <200 VAC> Connect the power supply to the terminal block. Install an earth leakage breaker*2 suitable to each model for the power supply.
Self-diagnosis: 5% F.S. or less Switch output PNP open collector output: Max. 80 mA Hysteresis: 3% F.S.
Air purge Power supply voltage Sensing DC mode Autobalance sensor [Body-mounting type] : 300 mA or less Autobalance sensor [High-precision type] : 200 mA or less When sensor is not used : 170 mA or less Current consumption Pulse DC mode DC mode Discharge stop signal Maintenance detection signal 170 mA or less Connected to 0 V (Voltage: 5 VDC or less, Current consumption: 5 mA or less) Connected
TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Max. load current 500 mA AC/DC (Resistance load) Min. load current 5 VDC 10 mA Output voltage 24 VDC 10% 200 mA MAX (No inductive load) Contact output signal Product side Customer system side 1 Contact input signal COM 1 k 2 Contact input signal 1: Run/Stop (Default setting) 4.7 k 1 k 3 Contact input
48 VAC, DC or less: 40 mA 100 VAC, DC or less: 20 mA Center of F.R.L. body D A P * For detailed specifications of the IS10 series, refer to the IS10 series section on the SMC website: https://www.smcworld.com Model P A B C D Applicable AC size IS10T-20-D 1/8, 1/4 28 77.6 60.1 42 AC20-D IS10T-30-D 1/8, 1/4, 3/8 31 85.6 64.1 53 AC30-D IS10T-40-D 1/4, 3/8, 1/2 39 93.6 68.1 71 AC40-D IS10T-
), 0.95 W DC (40 mA) Note 3) 24 VDC 3-position exhaust center 0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3) 12 VDC Inrush 0.96 VA (10 mA), Holding 0.96 VA (10 mA) 100 VAC Power consumption (Current) Inrush 1.0 VA (9 mA), Holding 1.0 VA (9 mA) 3-position pressure center 110 VAC Inrush 1.26 VA (6 mA), Holding 1.26 VA (6 mA) 200 VAC Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA) 220 VAC Note 1)
Max 30 VDC, 50 mA 3 PNP open collector Max 30 VDC, 50 mA PNP open collector Max 30 VDC, 50 mA 3 Output transistor mode Power supply voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC Power consumption 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less
), 0.95 W DC (40 mA) Note 3) 24 VDC 3-position exhaust center 0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3) 12 VDC Inrush 0.96 VA (10 mA), Holding 0.96 VA (10 mA) 100 VAC Power consumption (Current) Inrush 1.0 VA (9 mA), Holding 1.0 VA (9 mA) 3-position pressure center 110 VAC Inrush 1.26 VA (6 mA), Holding 1.26 VA (6 mA) 200 VAC Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA) 220 VAC Note 1)
), 0.95 W DC (40 mA) Note 3) 24 VDC VQ 4/5 2(B) (A)4 0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3) 12 VDC Inrush 0.96 VA (10 mA), Holding 0.96 VA (10 mA) (R1)5 1 (P) 3(R2) 100 VAC VQC 1/2 Power consumption (Current) 4-position dual 3-port valve Note) Inrush 1.0 VA (9 mA), Holding 1.0 VA (9 mA) 110 VAC 4(A) 2(B) (A) VQC 4/5 Inrush 1.26 VA (6 mA), Holding 1.26 VA (6 mA) 200 VAC 5(R1) 1(P) 3(R2
Note 1) In case of types with no air cushion, a rubber bumper is used. 6-6-7 7 Series MB Without Mounting Bracket Basic: (B) Cushion valve WV Port G 2-RcP MM G With rod boot E E D e MB Effective thread 2 x 4-J C B A K F N MA 13 9 f l N h S + Stroke H ZZ + Stroke Without Air Cushion Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588
V, 80 mA Residual voltage 1.5 V or less When used as a switch output device Max. 80 mA Residual voltage 1.5 V or less -19No.PS-OMW0012-C Pressure Setting Default settings When the pressure exceeds the set value, the switch will be turned on.