SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S25H-3000-F7PWL"

Lead wire length Internal circuits Model 3m (~9ft) 0.5m (~1 1/2ft) 53 (1.9) 10 (0.35) D-Y59A, Y69A, Y7P D-Y59A, Y69A 50 (1.8) 9 (0.3) D-Y59B, Y69B, Y7PV Dimensions (mm) DC (+) Brown [Red] 1in = 25.4mm D-Y59A, Y59B D-Y7P Mounting screw M2.5 x 4l Main switch circuit OUT Black [White] Slotted-head set screw 2.5 3.4 Indicator light 6.2 6.2 5 DC () Blue [Black] 29 (500) (3000) (5000) D-Y7P (V)

Weights (g) Lead wire length Auto switch part no. 3m 0.5m Internal circuits D-Y59A, D-Y69A, D-Y7P, D-Y7PV 53 10 D-Y59B, D-Y69B 50 9 D-Y59A, D-Y69A Dimensions DC(+) Brown [Red] D-Y59A, D-Y59B D-Y7P M2.5 x 4 Slotted set screw Main circuit of switch OUT Black [White] 2.5 3.4 Indicator light 6.2 6.2 5 DC() Blue [Black] 29 (500) (3000) (5000) D-Y7P(V) 12.5 Most sensitive position DC(+) Brown [

) (5000) DC () Blue [Black] 5 l Operating range (see table below) 12.5 Most sensitive position D-Y7P(V) D-Y69A, Y69B D-Y7PV Mounting screw M2.5 x 4l Slotted set screw DC (+) Brown [Red] 2.5 Indicator light Main switch circuit Main switch circuit (500) (3000) (5000) 6.2 OUT Black [White] 27.3 DC () Blue [Black] 3.4 D-Y59B, Y69B 8.5 5 OUT (+) Brown [Red] l Operating range (see table below)

Weights Unit: g Lead wire length Model 3m 0.5m 53 10 D-Y59A, Y69A, Y7P, Y7PV Internal circuits Lead wire colors inside [ ] are those prior to conformity with IEC standards. 50 9 D-Y59B, Y69B Dimensions D-Y59A, Y69A D-Y59A, Y59B D-Y7P Mounting screw M2.5 x 4l Slotted set screw DC (+) Brown [Red] Indicator light 2.5 3.4 Main switch circuit OUT Black [White] 6.2 29 (500) (3000) (5000) DC ()

Weights Unit: g Lead wire length Model 3m 0.5m 53 10 D-Y59A, Y69A, Y7P, Y7PV Internal circuits Lead wire colors inside [ ] are those prior to conformity with IEC standards. 50 9 D-Y59B, Y69B Dimensions D-Y59A, Y69A D-Y59A, Y59B D-Y7P Mounting screw M2.5 x 4l Slotted set screw DC (+) Brown [Red] Indicator light 2.5 3.4 Main switch circuit OUT Black [White] 6.2 29 (500) (3000) (5000) DC ()

SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000 mm Connector cable mounting 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Triangle mark Arrow mark Connector Assembly with Cover: Dimensions (40) Gray (10) (8) (4.1) Red Black (6.9) Note) Connector cable should be mounted in the correct direction.

Note 5) Dusttight/splash proof enclosure (IP65) is not available with interface regulator. 0.1 00 2500 2000 1500 1000 500 3000 Flow rate (l/min (ANR)) ARBQ5000-00-P (P A) 0.7 0.6 Outlet pressure (MPa) 0.5 0.4 How to Order 0.3 0.2 0.1 Regulating port Solenoid valve Interface regulator 00 2500 2000 1500 1000 500 3000 A ARBQ5000-00-A-1 Flow rate (l/min (ANR)) VQ50 (Plug-in type) B ARBQ5000-

32 40 3000 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke specification (XB11) applies to the strokes exceeding 2000 mm.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bourdon tube Brass Weight (kg) 0.04 0.05 AC2000/2500/3000 AR2000/2500/3000 AW2000/3000 Applicable model Note 1) When installing a pressure gauge, be careful not to fasten too tight. Excessive tightening will result in damage.

VCW 20 1 G Clip Series Lead wire length 20 30 40 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Class 2 Class 3 Class 4 Flat head screwdriver Voltage Solenoid coil 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Electrical entry Insert a flat head screwdriver into the hook section of the clip groove.

PDisconnectionPress the lever against the connector housing and pull it outward from the solenoid : 300 600 1000 1500 2000 2500 3000 5000 For DC SYJ312-5LO-M3 SY100-30-4A-20 6 10 15 20 25 30 50 How to Order To order a valve with lead wire length of other than 300mm, indicate part numbers. of the valve without connector and the required connector assembly separately.

Recommended terminals NVFR 2000, 3000: 1.25-3, 1.25-35, '1.25Y-3N, 1.25Y-3S (1.25mm centers) (spade type, size 4, 22-16 AWG). . NVFR4000: 1.25-3.5M. 1.25Y-31. 1.25Y-3M. .

E/P Pressure Regulator Manufacturing Pneumatics Worldwide Electro-Pneumatic Regulator Compliant Electronic Vacuum Regulator How to Order ITV 2030 SEN DUQ00833 2 X26 Port Size 1 2 3 4 1/8 (1000) 1/4 (1000, 2000) * 3/8 (2000, 3000) * 1/2 (3000) Body Size 1010 1030 1050 2010 2030 2050 2090 3010 3030 3050 Made to Order * Note: 2090 available with 1/4 port only.

Support brackets are not for mounting; use them solely for providing support. 10 10 0 1000 2000 3000 4000 0 1000 2000 3000 4000 Support spacing (L) Support spacing (L) (mm) (mm) 1358 MY1W Series Auto Switch Mounting 1 Proper Auto Switch Mounting Position (Detection at stroke end) MY1MW (Slide bearing guide type) 16, 20 25, 32, 40, 50, 63 B A B A Proper Auto Switch Mounting Position (mm) D-Z7

End plate ass'y 1 pc. 2500 3000 A B 146 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM2500, 3000 P Dimensions Symbol A B C D E F G H I J K L M N O P Model NARM2500 .24 .67 1.73 2.20 1.65 4.98 2.28 1.77 .67 .83 1.50 1.65 1.14 1.89 2.68 1.32 (6) (17) (44) (56) (42) (126.5) (58) (45) (17) (21) (38) (42) (29) (48) (68) (33.5) NARM3000 .28 .83 2.13 2.68 2.17 6.04

A variety of mounting options and port connections make the F-3000 Series an excellent choice for the O.E.M.

Core wire colors 010 030 050 1000 [mm] 3000 [mm] 5000 [mm] 1 2 3 4 5 Brown White 4 3 Black Blue Socket connector pin arrangement Reverse keyway Connections Gray !1 End plate 66 2 x M4 (mounting hole) EX9 EA03 12.5 10 60 13.2 75 6 18 1694

Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm Double solenoid part no. Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm Lead wire length Single/3 position part no. AXT661-12A AXT661-14A AXT661-14A-6 AXT661-14A-10 AXT661-14A-20 AXT661-14A-30 Lead wire length Single/3 position part no.

Terminal + Analog output Main Circuit Black OUT (White) GND terminal PSE Blue DC () (Black) ZSE4 ISE4 Shield wire ZSE5 ISE5 ZSE6 ISE6 ZSE3 ISE3 Dimensions GS PSE520-01, T01 PS 3000 59.5 ISA (55.5) 35 10 50 ZSE1 ISE1 33.5 M5 X 0.8 depth 5 ZSE2 ISE2 ZSP ISl 01: R(PT) 1/8 T01: NPTF 1/8 Width across flats 19 32 32 ZSM Protective tube (Resists bending) PFl IFl PSE520-02, T02 3000 61.5 (55.5) 35