SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2L16-700-B"

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 2", Port Location: In-line, Auto Switch: Band Mounting, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 4", Port Location: Perpendicular, Auto Switch: Band Mounting, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 4", Port Location: In-line, Auto Switch: Band Mounting, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 5", Port Location: Perpendicular, Auto Switch: Band Mounting, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 6", Port Location: Perpendicular, Auto Switch: Band Mounting, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 8", Port Location: Perpendicular, Auto Switch: Band Mounting, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 8", Port Location: In-line, Auto Switch: Band Mounting, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 (5/8"), Stroke: 3", Port Location: Perpendicular, Auto Switch: Band Mounting, Number: -

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 2 1/4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 6", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 4", Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 2 1/4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 6", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 4", Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Nozzle length (D) 123 332 632 A B C Body color White Dark blue W BU Connection size Piping connection type Piping connection method Size and model no.

N.O. 1 (P) 3 (R) 1 (P) 3 (R) a c e d a c e d (A) (A) 2 2 g g 3 (R) 1 (P) 3 (R) 1 (P) b b f f Component parts Replacement parts Note Zinc die-casted No.

-X10 X10 X10 IZS 40 IZS 42 1660 1660 10 10 B B Ordering example) Bar length Type 41 42 520 700 760 880 940 1000 1060 1180 1240 1360 1420 1480 1540 1660 1720 1780 1840 1960 2020 2080 2140 2200 2260 2380 2440 Symbol Specifications Contents Model with drop prevention cover The main unit is shipped fitted with a drop prevention cover available as an option.

Auto Switches/Proper Mounting Position at Stroke End Detection B A (mm) D-A9, D-A9V (mm) D-M9, D-M9V (mm) D-F9W, D-F9WV A A A B B B Operating range Operating range Operating range Nominal size 16 25 Nominal size 16 25 Nominal size 16 25 3 44 116 48 112 48 112 8 8.5 3.5 54 156 58 152 58 152 Auto Switch Mounting When mounting the auto switches, they should be inserted into the actuators switch

Nil M5 x 0.8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 TN NPT1/8 NPT1/8 NPT1/8 NPT1/4 TF G1/8 G1/8 G1/8 G1/4 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 d b C H B H 4 8 8 10 d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 B 14 26 32 41 C 16.2 30 37 47.3 Part number SNJ-016B SN-020B SN-032B SN-040B Applicable bore size (mm) 15 20 25, 32 40 161 Specific Product Precautions Be sure to read before handling.