Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9PW, Lead Wire Length(m): 1, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9PW, Lead Wire Length(m): 0.5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9PW, Lead Wire Length(m): 0.5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9PW, Lead Wire Length(m): 5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9PW,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: M9PW,
magnet, Auto Switches: M9PW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Type of Mount Support: U-Shaped Clevis Type, Rod Boot: Without rod boot, Custom-made Specifications: None
, Auto Switches: M9PW, Lead Wire Length(m): 5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Pivot Bracket: Without bracket, Rod End Bracket: U-Shaped Knuckle Joint, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: With Coil Scraper, Stroke adjustment symbol: -
: Built-in magnet, Port thread type: Rc, Auto Switches: M9PW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: M9PW, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.12~1.0, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto Switches: M9PW,
): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9PW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Type of Mount Support: Head end trunnion type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional, Auto switch mounting bracket: -
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 16, Stroke(mm): 400, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 20, Stroke(mm): 400, Max.
, Stroke Adjustment Mechanism: Not Provided, Cylinder internal diameter(mm): 80, Auto switch: M9PW, Number Of Switches: 2 pcs., Lead wire length: 0.5 m, Made to order specifications: None, Connector type for gripper opening/closing: M8 3-pin, Port thread type: G, Center pusher: Without center pusher
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 16, Stroke(mm): 400, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 40, Stroke(mm): 400, Max.