Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.
Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. Observe the proper tightening torque for mounting an auto switch.
/s2 (Without pressure sensor and pressure switch, With pressure sensor) Impact resistance Note 2,3) 100m/s2 (With pressure switch) Standard CE, RoHS Note 1) The characteristics are satisfied when tested for 2 hours in each of the X, Y and Z directions at 10 to 500 Hz without energization.
switch) 150m/s2 (Without pressure sensor and pressure switch, With pressure sensor) Impact resistance Note 2,3) 100m/s2 (With pressure switch) Standard CE, RoHS Note 1) The characteristics are satisfied when tested for 2 hours in each of the X, Y and Z directions at 10 to 500 Hz without energization.
Example) S2S2: Standard cable (2 m) + Driver (LECSS2) S2 : Standard cable (2 m) Nil : Without cable and driver Applicable Stroke Table 4 )Standard DProduced upon receipt of order Stroke (mm) Model 200 400 300 500 600 700 800 900 1000 1200 1500 LEJS40 LEJS63 ) ) ) D D ) ) ) ) D D D D ) ) D ) D D D 4: Strokes other than those shown above are produced as special order (1 mm increments).
.: 1.4 mm Vibration resistance1 30 m/s2 Without pressure sensor/switch With pressure sensor 20 m/s2 With pressure switch Impact2, 3 resistance 150 m/s2 Without pressure sensor/switch With pressure sensor 100 m/s2 With pressure switch Standards CE marking, RoHS 4 Refer to the Valve assembly on page 32 for the valve model number. 5 ZK2-VAmR: After instantaneous energization of the supply valve
Lead wire length Nil 6 10 15 20 25 30 300 mm (Standard) 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm How to order When requiring a vacuum unit equipped with valves with lead wires of 600 mm or more, specify the vacuum module valves without the standard connectors and order the required connector ass'ys separately. Example) ZR120S1-K15MZ-EC . 1 pc.
800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VP4 VZ1120--M5 (Piping: 6 x 1 m) VZS VFS VS4 AS2001F-06/AN120-M5 AS2301F-M5-06/AN120-M5 Speed controller/Silencer It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
Ambient and fluid temperature (C) 10 or less Response time (ms) (1) 20 Max. operating frequency (Hz) Manual override Non-locking push type, Locking slotted type Push-turn locking slotted type Push-turn locking lever type {SY1 4, SY1 4A only} 1 2 1 2 Not required Lubrication Unrestricted Mounting position 150/30 Impact/Vibration resistance (m/s2) (2) Body ported Dustproof Enclosure Note 1)
Vacuum pressure switch Vacuum pressure switch 15 55 Vacuum Pressure Switch: ZSE2-0X15 55 Grommet: ZSE2-0X15 55 Connector: ZSE2-0XC Indicator light (Red) Pressure setting trimmer Indicator light (Red) JIS Symbol Pressure setting trimmer 20 20 35.6 7 35.6 7 Lead wire length Lead wire length Vacuum port (V) M5 (or M6) 600 9.5 50 600 2 50 Vacuum pressure SUP port (PV) M5 (or M6) 57.6 18 6.5 6.5
Specifications Air Fluid Max. 50C Ambient and fluid temperature (C) Response time (ms) (1) 10ms or less Base mounted 20 Max. operating frequency (Hz) Manual override Non-locking push, Locking slotted, Push-locking slotted, Push-locking lever Not requited Lubrication JIS Symbol Free Mounting position Impact/Vibration resistance (m/s2) (2) 150/30 SY11 (A) 3 4 SY12 (A) 3 4 Dust-proof Enclosure
0.27 0.17 1.1 0.21 0.23 0.90 1 8 VP4 Exhaust center 3 position VZS2450 22 or less 600 0.2 0.31 0.13 1.3 0.25 0.12 1.1 1 8 VZS Pressure center VZS2550 600 22 or less 0.2 0.33 0.19 1.4 0.26 0.12 1.2 1 8 VFS Double check VZS2650 500 26 or less 0.3 0.81 0.71 1 8 VS4 Note 1) Min. operating cycle is based on JIS B 8375 (One time per 30 days).
Non-locking push type Unrestricted 150/50 m/s2 Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port).
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Nil 6 10 15 20 25 30 50 G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Handling Caution 1) Do not apply excessive external force or shock (100m/s2 or more) to the product Even if the there are no problems with the appearance of the controller, high voltage power supply module or bar, the damage of the internal components may cause malfunction. 2) When the bar length exceeds 820mm, hold the both ends and the middle of the bar so that moment load is not applied
Example) Obtain the air flow rate for P1 = 0.4 [MPa], P2 = 0.3 [MPa], T = 20 [C] when a solenoid valve is performed in C = 2 [dm3/(sbar)] and b = 0.3. 293 According to formula 1, the max. flow rate = 600 x 2 x (0.4 + 0.1) x = 600 [L/min (ANR)] 273 + 20 0.3 + 0.1 Pressure ratio = = 0.8 0.4 + 0.1 Based on Graph (1), it will be 0.7 if the pressure ratio is 0.8 and the flow rate ratio is b
Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
Built-in magnet for auto-switches CE1 CE2 Maximum Driving Speed of Cylinders ML2B 1000 1000 900 900 C J G5-S Load factor: 10% Load factor: 50% 800 800 Cylinder speed (mm/s) Cylinder speed (mm/s) 700 700 600 600 CV 500 500 400 400 MVGQ 300 300 200 200 CC 100 100 0 0 12 16 20 25 32 40 50 63 80 100 RB SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) J Series Variations DDetailed specifications