SMC Corporation of America
Elite Part Number Search
Search Results "LEY40EA-150C-R1"

Size: 40, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 350mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 40, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: RA (10m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 40, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 40, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: D (Double Clevis, Top Mounting), Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)

Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail, Cable Connector: None, Actuator: LEY, Body Size: 40, Motor Mounting: Top Mounting Type, Lead: 16: 10mm; 25: 12mm; 12; 32/40: 16mm, Stroke: 200mm

Protocol: EtherNetIPâ„¢, Single Axis, STO Function: 1 Axis, w/STO Sub-function, Mounting: DIN Rail Mounting, Actuator: LEY, Body Size: 40, Motor Mounting: Top Mounting, Lead: 16: 10mm; 25: 12mm; 32, 40: 16mm, Stroke: 200mm

Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 300mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: 10m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication

Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Top Mounting & In-line, Actuator Cable Type, Length: 1.5m, Controller: Ether Net/IPâ„¢, Mounting: Screw Mounting, I/O Cable: -, Communication Plug Connector: -

Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 200mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication

Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Top Mounting & In-line, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication Plug Connector: -

Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 350mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Top Mounting & In-line, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication Plug Connector: -

Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Top Mounting & In-line, Actuator Cable Type, Length: 10m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication Plug Connector: -

Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Top Mounting & In-line, Actuator Cable Type, Length: 5m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication Plug Connector: -

Fl ui d ot her t han com pressed ai r Ai r pressure m ore t han 1. 0 M Pa* and 0. 05M Pa or l ess * O p tio n H : 1.6 M P a O n ly 150C 550C Ref er draw i ngs or cat al ogue f or const ruct i on and speci f i cat i ons. U nderst and t hi s operat i on m anual w i l l be revi sed w i t hout not i f i cat i on.

Fl ui d ot her t han com pressed ai r Ai r pressure m ore t han 1. 0 M Pa* and 0. 05M Pa or l ess * O p tio n H : 1.6 M P a O n ly 150C 550C Ref er draw i ngs or cat al ogue f or const ruct i on and speci f i cat i ons. U nderst and t hi s operat i on m anual w i l l be revi sed w i t hout not i f i cat i on.

. ** O p ti o n H : 1.6 M P a O n ly 150C 550C Ref er draw i ngs or cat al ogue f or const ruct i on and speci f i cat i ons. U nderst and t hi s operat i on m anual w i l l be revi sed w i t hout not i f i cat i on. To get t he best perf orm ance f rom your purchase, be sure t o read t hi s m anual caref ul l y bef ore use.

. ** O p ti o n H : 1.6 M P a O n ly 150C 550C Ref er draw i ngs or cat al ogue f or const ruct i on and speci f i cat i ons. U nderst and t hi s operat i on m anual w i l l be revi sed w i t hout not i f i cat i on. To get t he best perf orm ance f rom your purchase, be sure t o read t hi s m anual caref ul l y bef ore use.

Accessories -XB6 Heat resistant cylinder (-10 to 150C) w/o auto switch only Note 1) MK-A012Z MK-A016Z MK-A020Z 12 16 20 25 32 40 50 63 Clamp bolt, Hexagon socket head cap screw, Hexagon nut, Spring washer -XC22 Fluororubber seals Note 2) Note 1) Except 12 and 16. Note 2) The bumper is a standard product.

It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing.

Proof pressure 0 to 150C Operating temperature Burst Pressure and Heat Resistance Performance 4.0 3.5 3.0 2.5 Pressure (MPa) 2.0 1.5 1.0 0.5 0 20 40 60 80 100 120 140 Temperature (C) 1/8", 3/16", 1/4", 4, 6 tubing 3/8", 10 tubing 1/2", 12 tubing 3/4", 19, 1", 25 tubing 3 High Purity Fluoropolymer Fittings Series LQ1 Construction Quadruple sealing construction The quadruple sealing construction