screw (M3 x 0.5 x 10l ) Switch spacer Switch mounting nut Data 50 25 to 600 BQ-2 63 25 to 600 Please contact SMC regarding non-standard strokes.
, 125, 160, 200, 250, 320, 400, 500, 600 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 Intermediate strokes are available.
mounting screw (M3 x 0.5 x 10l ) Switch spacer Switch mounting nut Data 50 25 to 600 BQ-2 63 25 to 600 Please contact SMC regarding non-standard strokes.
, 125, 160, 200, 250, 320, 400, 500, 600 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 Intermediate strokes are available.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
flow rate: 5L/min, Ambient temp.: 25oC 1) Cooling capacity 1200 1000 Facility water 25oC Cooling capacity W Facility water 10oC 800 Facility water 35oC 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-9 Cooling capacity (HED005) 2) Heating capacity 1400 1200 Heating capacity W 1000 Facility water 35oC 800 Facility water 10oC 600 Facility water 25oC 400 200 0 0 10 20
Mode button Set button 1s 1s or Mode button 1s Mode button 1s Set button 1s Set button 1s or Mode button 1s Mode button 1s Set button 1s Set button 1s Mode button 1s Mode button 1s Set button 1s Set button 1s Upper limit setting% Lower limit setting% Fig.38 No.IP8S-OM09 49 (600) Dead band setting Set dead band (d-b).
B -If the set value of the dead band (parameter code: 600) is changed, return the set value to 0. Input current adjustment error -Input current deviates widely from -Check that the Input current 0006 (4mA DC) 4mA DC. is 4mA DC. Input current adjustment error -Input current deviates widely from -Ensure that the input current 0007 (20mA DC) 20mA DC. is 20mA DC.
, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact SMC if the maximum stroke will be exceeded.
600 Nominal filtration rating 0.01m (95% filtered particle size) Max. 0.1mgf/Nm (before saturated with oil: 0.01mgf/Nm or less, approx. 0.008ppm) Note 2) Outlet side oil mist concentration Element life Bowl material Drain capacity cm Weight kg Accessories Bowl guard AFD30 2 years or when the pressure drop hits 0.1MPa.
0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 200 400 600 800 1000 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1 MPa 6 Series IR1000/2000/3000 Series IR3000 Flow rate characteristics Relief characteristics Pressure characteristics Testing methods conform to JIS B8372.
Use a regulator or filter regulator with a back flow mechanism when mounting a 3 port valve for residual pressure release on the IN side to ensure the release of the AC25 Rc 3/8 AC55 Rc 1 0 0 200 400 600 800 Flow rate L/min (ANR) 4000 6000 8000 2000 10 0 0 Flow rate L/min (ANR) residual pressure.
When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to be described by l (liter). 1 dm3 = 1 l 16 Solenoid Valve Flow Characteristics C : Sonic conductance [dm3/(sbar)
600 0.01 m (95% filtered particle size) Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2) Nominal filtration rating Outlet side oil mist concentration Bowl material Bowl guard Drain capacity (cm3) Weight (kg) AFD30 Polycarbonate Option 8 0.18 Standard 45 0.44 25 0.22 45 0.49 Note 1) When the inlet pressure is 0.7 MPa.