25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal
Arm length L A Arm length L A Table 1 Table 1 A Model A Model CKZ3N50 CKZ3N63 CKZ3T50 CKZ3T63 5 10 Series CKZ3N Series CKZ3T 10 10 50 63 Arm length L: 150 mm Arm length L: 200 mm 3000 3000 Peak clamping force position 2500 2500 Peak clamping force position 0.7 MPa 2000 2000 Clamping force (N) Clamping force (N) 0.5 MPa 0.7 MPa 1500 1500 1000 1000 0.5 MPa 0.3 MPa 0.3 MPa 500 500 0 0 0 0.5
Auto Switch Common Specifications Solid state switch Type Reed switch 3-wire: 100 A or less 2-wire: 0.8 mA or less Leakage current None Operating time 1 ms or less 1.2 ms 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 VDC Mega (between lead wire and case) Insulation resistance 1000 VAC for 1 minute 1500 VAC for 1 minute Withstand voltage (between lead wire and case) (between lead
Auto Switches Common Specifications Solid state auto switch Type Reed auto switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less Leakage current None Operating time 1 ms or less 1.2 ms Impact resistance 1000 m/s2 300 m/s2 50 M or more at 500 VDC Mega (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire
VQC5000 Bore size MB, CA1 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm CS1 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Average speed [mm/s] 50 63 80 100 125 140 160 180 200 250 1100 Vertically upward Horizontal 1000 900 800 700 600 500 400 300 200 100 0 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open
mm (For the ZNC80) The values are for when the connection is as follows: Fitting min. hole diameter: 4.5, Tubing size: 6 x 4, Length: 500 mm *4 No freezing or condensation.
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.
Electrical entry Grommet Lead wire Vinyl sheath cable 4.8, 0.5 mm2, 2-wire Impact proof 1000 m / s2 Insulation resistance 50 M or more under the test voltage 500 VDC (between case and cable) Withstand voltage 1000 VAC 1min (between case and cable) Ambient temperature -10 to 60 C Enclosure IEC60529 criteria IP67 Standards CE, UL, RoHS Magnetic field resistance When the alternative welding
100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 Communication cable PC PC is prepared by customer) Refer to 8CN2 TB/PC Power supply connector(P.23) for usage.
100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2CN Communication cable PC PC is prepared by customer) Refer to 8CN2TB/PC Power supply connector for usage.
Series SQ2000 Series SQ1000 C 6 10 16 20 25 32 40 Series CM2 Bore size (mm) 6 10 16 20 25 32 40 Series CM2 Bore size (mm) Average speed (mm/s) 800 700 600 500 400 300 200 100 0 Average speed (mm/s) Series CJ2 kit Series CJ2 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation Perpendicular, upward actuation Horizontal actuation How to Increase Manifold Stations
actuation 800 600 400 200 VF1120-01 0 1000 800 600 400 200 VF3130-02 0 1000 800 600 400 200 VF5120-03 0 With : when using steel piping Base Mounted 0.5 MPa = 73 psi Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor
(1) 0+55() 0+40() -20+65() -15+70() 90%RH() 80%RH() 90%RH() () 1000m LECS-S5 LECS-S7 LECS-S8 () 5.9m/s2 XY49m/s2 .
CN1IF(CONT) 18 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SWOFF(LEC)(LEC) (LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.
(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V LECOFF 25 - 7CN3: 1 5 4 3 2 1 2 5 4 3 2 1 9 8 7 6 9 8 7 6 3 RXDTXD-P / 4 5 DGND 6 VP 7 8 RXD/TXD-N / 9 PRODIBUS DP 6GK1 500-0FC106ES7 972-0BA12-0XA0 PROFIBUS DP 26 - 8CN1:IF CONT 81 5 (LEC) LEC-CG1-1 LEC-CG2-1 LEC-CG2b) M12 4pin b) M12 4pin
Common Specifications Reed switch Solid state switch Style None 3 wire style: 100 mA or less 2 wire style: 1mA or less Current leakage 1 ms or less (2) 1.2ms Operating time 300m/s2 1000m/s2 Shock resistance 50M or more at 500V DC (Electrical wire, Between bowls) Insulation resistance 1 minute at 1500V AC(1) (Electrical wire, Between bowls) 1 minute at 1000V AC (Electrical wire, Between bowls
VQ44 500 1 A side COM 6 Note 1) There is no polarity. It can also be used as COM. Note 2) Double wiring is used on sub-plate VQ410 .
Cylinder Speed Chart Bore size Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Enclosure Series Average speed (mm/s) IP65 compatible T kit (Terminal block box) 5 wiring types have been standardized to facilitate easy wiring work and maintenance.