Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Lever Style
The ZSE40A(F) series is a high precision digital pressure switch, providing improved functions, performance and variations over the previous ISE40 series. Abnormal values can be seen at a glance on the 2-color display. The settings of the master pressure switch can be copied to up to 10 slave pressure switches, reducing the setting work, and preventing mistakes in setting. Other features
Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø4 One-touch Fitting, Output Specification: PNP Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø4 One-touch Fitting, Output Specification: PNP Open Collector 2 Outputs+Copy Function, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Copy Function, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: ø4 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: R1/8 w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: R1/8 w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: R1/8 w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: PNP Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: NPT1/8, w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Copy Function, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: ø6 One-touch Fitting, Output Specification: PNP Open Collector 2 Outputs+Copy Function, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: ø4 One-touch Fitting, Output Specification: PNP Open Collector 2 Outputs+Copy Function, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: -, Lead Wire: -