For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that cannot vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that can not vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.
Never use in an atmosphere of explosive gases. 6. Do not use in an environment where there is excessive impact shock. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
Avoid using and storing this product in the following environments since they may cause damage to this product. a) Avoid using in a place that exceeds an ambient temperature range of 0 to 55C. b) Avoid using in a place that exceeds an ambient humidity range of 35 to 65% Rh. c) Avoid using in a place where condensation occurs due to a drastic temperature change. d) Avoid using in a place in
Align carefully when connecting to a load having an external guide mechanism. Mechanically jointed rodless cylinders can be used with a direct load within the allowable range for each type of guide, but careful alignment is necessary when connecting to a load having an external guide mechanism. As the stroke becomes longer, variations in the center axis become larger.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Furthermore, since valves and cylinders, etc., are not guaranteed for zero air leakage, it may not be possible to hold a stopped position for an extended period of time. Contact SMC in case it is necessary to hold a stopped position for an extended period.
Avoid using in a tightly shut container. Install it in a well-ventilated area. Furthermore, do not touch it while it is being energized or right after it is energized. 2) Install an air filter. Install an air filter close to the valve on the upstream side. A filtration degree of 5 Mm or less should be selected. 3) Install an aftercooler or air dryer, etc. 3.
Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
asterisk () can be mounted on a band (excluding D-A9V), rail, tie-rod or square groove with an auto switch mounting bracket.
Avoid touching the switch directly as this may cause a burn. Operating Environment Warning 1. Never use in the presence of explosive gases. The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2.
Type Series VQ5000 Dimensions (mm) 1in 25.4mm Bottom port diagram With connector on U side (FU) 106 46.8 59.2 83.5 9 9 55.5 M5 ground screw 2n-1/2 (ports A, B) 34.5 n U side X 12 B 2 A 4 6 B A B 2 A 4 5 SMC SMC SMC SMC SMC B A B 2 A 4 4 B A P=41 L1 L2 B 2 A 4 3 B A B 2 A 4 2 B A 34.5 46 68.5 P = 41 A 4 B 2 1 B A 58.5 X 12 Stations 2-1/8 (external pilot port) 15.5 22 51 69 117 42 16 107.8
Drain Tube Caution Compressed Compressed air outlet air inlet A tube with an outside diameter of 0.47 in (12 mm) is attached as a drain tube. Use this tube to discharge condensate to a drain tank, etc. Do not use the drain tube in an upward direction. Do not bend or crush the drain tube.
Series 25 19 dB (A) Page 5-10-4 VEX AN101-01 AN110-01 AN120-M5 AN120-M3 BC sintered body type Ideal for the exhaust of a compact valve or pilot air. 16 dB (A) 21 dB (A) 18 dB (A) 13 dB (A) 100 m AN Page 5-10-5 Silencers Exhaust Cleaner 70 m AMC One-touch fitting connection type Can connect with One-touch fitting directly. 25 dB (A) 30 dB (A) It differs depending upon the model.
Install an auto switch on the opposite side of the port. 3. Use a pipe fitting with 7 mm width across flats or 8 external diameter or less.
Manifold Options JIS symbol Blanking plate assembly VVCW 0 3A 2 A Series Material 2 3 4 Class 2 Class 3 Class 4 Plate material C37 Stainless steel Seal material Symbol A H FKM This is used by mounting it on the manifold block when a valve is removed for maintenance, or when the mounting of an additional valve is planned, 5 Series VCL Direct Operated 2 Port for Oil Dimensions (mm) (N.C.)
Conforming to ISO 16030-2001, the chamfered dimensions shown in the First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a wrench. A reference value for the tightening torque is 1 to 1.5 Nm. Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage. table below are recommended.