AXT100-DR7 L dimension Select L dimension from the table below and enter an applicable symbol.
(different sides, same side) Solid state switch 20 25 Y7BW(V) 1pc. 2pcs. (different sides, same side) 20 30 D-Y7BAL 1pc. Center trunnion is not included.
J 26 77.9 59.3 AC10-A 26 AC20-A 58.5 59.5 37.5 37.5 104.9 87.4 93.9 91.4 AC25-A 58.5 59.5 37.5 37.5 156.8 117.6 122.1 137.6 142.1 123.6 121.9 AC30-A 65 66 37.5 37.5 156.8 117.6 122.1 137.6 142.1 123.6 121.9 AC40-A 72 72 42.5 42.5 186.9 149.6 154.1 169.6 174.1 155.6 153.9 AC40-06-A 72 72 42.5 42.5 188.9 151.6 156.1 171.6 176.1 157.6 155.9 20 Standard specifications C E F G J Bracket
Power supply output VI: 20 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 20 [kVA] x 0.85 = 17 [kW] Cooling capacity = Considering a safety factor of 20%, 17 [kW] x 1.2 = W Efficiency Q = P = In this example, using an efficiency of 0.7: 13 0.7 = = 18.6 [kW] Cooling capacity = Considering a safety factor of 20%, 18.6 [kW] x 1.2 = 22.3 [kW] 20.4 [kW] *1
10 J 6 Mounting base side B D 10 9.5 Across AA MXP10-20 Without magnet and switch rail 2-M30.5, 3.5 deep 2-M20.4, 3 deep For magnet mounting For rail mounting 8 2.5 4.7 6-M30.5 15 15 4 deep L (mm) Model G H J K L M N S V W Z MXP10-10 8 32 52.4 20 20 21 6.5 10 44 40 60 MXP10-20 20 50 82.4 36 36 39 7.5 20 74 65 90 168 168 Precision Air Slide Table Series MXP Dimensions 12 MXP12 Scale:55%
EMO circuit An EMO (EMergency Off) circuit is an electrical circuit provided to shut off all power and ensure safe conditions when an emergency stop button (EMO button) is pressed in an emergency. Hardware interlock This is an equipment control circuit for shutting off power in case of trouble.
20 [dm3] : 4.2 x 103 [J/(kgK)] : 305 [K] (32 [C]) : 293 [K] (20 [C]) : 12 [K] (= T0 Tt) : 900 [s] (= 15 [min]) Example of current measurement units (Reference) : Unknown [cal/h] [W] : Water : (= r x V) [kgf] : 1 [kgf/L] : 20 [L] : 1.0 x 103 [cal/(kgfC)] Heat quantity by cooled substance (per unit time) Q Cooled substance Cooled substance weight m Cooled substance weight volume ratio c
Example) Assume circuit C with an operating pressure of 0.5 MPa, load weight of 10 kg, fluctuation to 20 kg and a cylinder bore of 32 mm.
Bore size CV Rod extended/retracted when energized 20 25 32 40 20 mm Piping 25 mm Built-in Magnet Cylinder Model Screw-in type Nil F Nil B MVGQ Rod extended when energized 32 mm Built-in One-touch fitting If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
Q F Depth of counterbore RB E J I M0.2 D W B + Stroke K L M0.2 A + Stroke E (mm) Bore size (mm) P Stroke range (mm) RB Note) H OA A B C D E F Q W I RA Y J K L M N OB TN TF 10 69.5 M3 x 0.5 M4 x 0.7 10 to 40 61.5 6 6 ( 5.8) 29 9 39.5 38 7 4 5 5 8 20 3.5 6.5 16 80.5 M4 x 0.7 M6 x 1.0 10 to 60 70.5 8 8 ( 7.8) 36 11.5 48.5 47 10 7 5 7 10 25.5 5.4 9 20 89 M5 x 0.8 M6 x 1.0 10 to 60
20 *1 This controls the speed of the slave axis when the speed of the main axis drops due to the effects of an external force and when a speed difference with the slave axis occurs.
Because sizes 10, 20, 30 and 50 have the table press fit into an angular type bearing, they cannot be disassembled. 50 11-9-30
3) Body size With bracket B AFM20 to 40 Port size C With bowl guard AFM20 Thread type Symbol 20 30 40 J Note 5) Float type auto drain (N.C.)
Models (mm) Internal volume (L) Number of arranged elements Weight (kg) Element length (L) Model N (Port size) G W A B C D E F H J K P 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 250 20 70 15 330 216.3 230 490 660 965 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 500 20 80 24 330 216.3 230 490 905 1220 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4
If resetting fails, an investigation by SMC Corporation will be required. Displayed in the case of an internal data error. System Error If the error can not be reset after the above measures are taken, then please contact SMC. -55No.PS-OML0003-J Specifications Model No.
H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 75 125.5 52 63 72.5 80.5 80 84.5 124 144.5 26 24.3 2.3 55 42 4.5 25 28 34 14 60.5 73 1 84 100 92 108 135.5 137 153 156 172 84 90 62 72 80 90 89 95 93.5 99.5 31 36 28.3 33.3 2.3 2.3 50 60 5.5 6.5 30 35 35 40 43 49 17.5 20 151.5 Port
(Based on SMCs test condition) Service life: 3 million cycles 3 Power consumption: 0.35 W 0.35 (24 VDC) (With light/surge voltage suppressor: 0.58 W) Water hammer: Reduced by 20% (2-port) 20 (Compared to existing model, VNH series) 3-port dual pressure type is standardized. (See applications 1 and 2.)
The display starts to blink next position (50 % or 20 %).
No 3000G 45-089 Stripper for round cable (2.0) can be used for a 2-wire type cable. 181 Applicable auto switch list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6