This is a legacy product, and replaced byZSE20-P-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .19453 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
This is a legacy product, and replaced byZSE20B-R-N01-W-X500, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20A-T-P-N01-J, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .24308 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20A-T-N01-J, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .22046 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?
This is a legacy product, and replaced byISE20B-Y-P-N01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .26455 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byZSE20F-N-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .17857 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
This is a legacy product, and replaced byISE20B-X-P-N01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .21220 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byZSE20B-Y-P-N01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
.=0.8MPa) ) F.S. (2) (3) (4) 0.010.8MPa(IR1000 0.005MPa) 1 IR1000 IR1010 IR1020 [MPa] MAX. 1.0 [MPa] () 0.05 [MPa] 0.0050.2 0.010.4 0.010.8 0.2% 0.5% 4.4L/min(ANR) [1.0MPa ] -560 Rc1/8 Rc1/8 [2 ] 0.14kg (1) (0.05MPa) (2) IR1000:0.2MPa (3)2 ON-OFF () (4) -4- (C)2 (C) (A) (A) (C) (A) (C) BLEED SUP(1) OUT(2) SUP N/ M Pa/ m M Pa/ ( S) () m 2 1 1 m N MPa M Pa
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: None, Attachment: C2 (Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: M (w/M5, Female Thread), Attachment: C2 (Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 02 (R 1/4), Option: M (w/M5, Female Thread), Attachment: C2 (Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 02 (R 1/4), Option: None, Attachment: C2 (Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: R 1/8, Option: w/M5, Female Thread, Attachment: Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: R 1/4, Option: None, Attachment: Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude
Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,
Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/4] 1/4, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,