Variations Dimensions mm Weight g Tip color Applicable tubing Model D1 D2 L TKS-06 16 Orange TRB0604, TRBU0604 58 45 D2 D1 TKS-08 18 Yellow TRB0806, TRBU0805 35 TKS-10 Blue 20 TRB1075, TRBU1065 62 50 TKS-12 Green 22 TRB1209, TRBU1208 Inner tubing material/TRB: Nylon, TRBU: Polyurethane L 9.7 (3/8")
(D1) TUH/Standard type 4 2.8 6 4.4 8 5.8 10 7.3 12 8.8 I.D. (D2) O.D. (D1) Tubing I.D. (D2) TUH/High pressure type TU 8 2.5 4 5 6.5 1in = 25.4mm Operating pressure 1.0MPa (at 20C) [145 psi @ 68F] TUH/High Pressure Type Same operating pressure as series TS soft nylon tubing, and a bending radius equivalent to series TU polyurethane tubing.
Connector entry direction D side U side Electrical entry External pilot supply port Indicator light IP65 available Without cable Cable length 1.5m Cable length 3m Cable length 5m U0 U1 U2 U3 U side D0 D1 D2 D3 D side 2 to 12 stations 2 to 12 stations Cable length 0.6m Cable length 1.5m Cable length 3m U0 U1 U2 D0 D1 D2 Kit F Kit F Kit L Kit L Type of connection T1 S Kit (Individual terminal
Y1002(ST2) Y1003(DOG) Y1004(LSP) Y1005(LSN) Y1006/(MD0) Y1007/(TSTP) Y1008(MOR) Y1009(COR) Y100A1(DI0) Y100B2(DI1) Y100C3(DI2) Y100D4(DI3) Y100E5(DI4) Y100F(CR) Y1010 Y1011 Y1012 Y1013 Y1014 Y1015 Y1016 Y1017 Y1018 Y1019 Y101A(RES) Y101B Y101C Y101D Y101E Y101F 3 46 3CC-Link 3.7.4 (1) 2()D10 H000A (16) X20 ON 2 RWw4 H000A RY28 RX28OND10D11 RWr4RWr5 3 47 3CC-Link (2) 2PA04(A-1)D1
The method for measuring the overshoot amount can be selected from the separate axis setting. 1pulse Digital waveforms SON, LSP, LSN, TL, TL1, PC, RES, CR, ST1, ST2, EMG, MD0, DOG, OVR, TSTP, TP0, TP1, CDP, TCH, MD1, SIG, SP0...SP2, DI0...DI7, D1, D2, D3 and D4 (Note 1) RD, SA, ZSP, TLC, INP, WNG, ALM, OP, MBR, DB, BWNG, CPO, ZP, POT, PUS, CDPS, ABSV, MEND, PT0...PT7 (Note 1) D1, D2, D3 and
(Note 2) D1, D2, D3 and D4 are for the manufacturer setting. See LECSS Operation Manual, section 3.5 for details of each digital waveform. -47- 6.9.2 Trigger wait When the Start button is clicked, the screen will be on stand-by. When trigger conditions are satisfied during the trigger wait, waveforms can be captured and displayed.
The method for measuring the overshoot amount can be selected from the separate axis setting. 1pulse Digital waveforms SON, LSP, LSN, TL, TL1, PC, RES, CR, ST1, ST2, EMG, MD0, DOG, OVR, TSTP, TP0, TP1, CDP, TCH, MD1, SIG, SP0...SP2, DI0...DI7, D1, D2, D3 and D4 (Note 1) RD, SA, ZSP, TLC, INP, WNG, ALM, OP, MBR, DB, BWNG, CPO, ZP, POT, PUS, CDPS, ABSV, MEND, PT0...PT7 (Note 1) D1, D2, D3 and
(Note 2) D1, D2, D3 and D4 are for the manufacturer setting. See LECSS2-T Operation Manual, section 3.5 for details of each digital waveform. -50- 6.9.2 Trigger wait When the Start button is clicked, the screen will be on stand-by. When trigger conditions are satisfied during the trigger wait, waveforms can be captured and displayed.
(mm) D (D1): 4, Applicable Tube Outer Dia. (in) D (D1): -, Tube Size Standard: Metric, Size of Body: 2
(mm) D (D1): 6, Applicable Tube Outer Dia. (in) D (D1): -, Tube Size Standard: Metric, Size of Body: 2
(mm) D (D1): -, Applicable Tube Outer Dia. (in) D (D1): 1/4, Tube Size Standard: Imperial, Size of Body: 2
(mm) D (D1): -, Applicable Tube Outer Dia. (in) D (D1): 1/4, Tube Size Standard: -, Size of Body: 3
VALVE, D1, VNA/B/C/D BODY PT 1/8, 0.02706 lb
D1 D2 L TKS-06 Orange TRB0604, TRBU0604 16 58 45 TKS-08 Yellow TRB0806, TRBU0805 18 TKS-DPH00071 (10 replacement blades) 35 TKS-10 Blue TRB1075, TRBU1065 20 62 50 TKS-12 Green TRB1209, TRBU1208 22 Inner tubing material/TRB: Nylon, TRBU: Polyurethane Dimensions D2 D1 L 9.7 (3/8") Able to strip without damaging the inner tubing The outer tube can be stripped without damaging the inner tube
Color KK130 T0604-250-X64 T0604-500-X64 200 200 475 475 52 52 120 200 5.1 9.4 Black, White D1 DM KDM KB D2 D3 W KR KA KQG2 KG KFG2 MS KKA KP LQ MQR T T IDK 463
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com T VMG D2 D1 L 9.7 (3/8") Able to strip without damaging the inner tubing The outer tube can be stripped without damaging the inner tube because a pawl is inserted between the inner and outer tube layers.
VQ 1 1 1 0 Y 5 LO VS7 (Example) Series Manual override Serial transmission unit kit VV5Q12-08C6SA-D1 set Manifold base No. VQ1110-5LO4 setsValve No. (Stations 1 to 4) VQ1210-5LO4 setsValve No.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: -, Digital Pressure Switch: -, Exhaust Check Valve: -, Exhaust Solenoid Valve: -
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m)