This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: None, Mounting: F (Front Flange), Style: N (Non-lube), Bore Size: 50mm, Port Thread: Rc, Stroke: 25mm, Option: N (w/o Rod Boot, w/o Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: 2 Position Single, Valve Type: Grommet, Cylinder Rod
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 25mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: Without cushion, Specification: Without
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: With Magnet, Mounting: Double Clevis, Bore Size: 32mm, Port Thread Type: NPT, Stroke: 25mm, Rod End Nut: Without Rod End Nut, Cushion: Without Cushion, Port Position: Port on Top - Cushion Valve Down, Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 25mm, Bellows/Cushion: w/o Cushion, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: NPT, Stroke: 25mm, Bellows/Cushion: w/o Cushion, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 25mm, Bellows/Cushion: w/o Cushion, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: Without cushion, Specification: Without
Magnet: Built-in Magnet, Series: Standard, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 80mm, Port Thread: Rc, Stroke A: 25mm, Rod Boot A: None, Cushion A: Rubber Bumper, Stroke Adjustment: None, +: +, Stroke B: 25mm, Rod Boot B: None, Cushion B: Rubber Bumper, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m
Magnet: Built-in Magnet, Series: Standard, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Port Thread: NPT, Stroke A: 25mm, Rod Boot A: None, Cushion A: Rubber Bumper, Stroke Adjustment: None, +: +, Stroke B: 125mm, Rod Boot B: None, Cushion B: Rubber Bumper, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired Connector
Magnet: Built-in, Series: with End Lock, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: NPT, Stroke: 25mm, Rod Boot: w/o Gaiter, w/o Cushion, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Non-locking Type, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 0.3m Cord Length
CH2 double acting hydraulic cylinders conform to JIS B 8367 specifications. Surge pressure generated when running into the cushion has been reduced by 30% or more compared to the CH series, due to the CH2s cushion seal system. Separate construction of the rod cover simplifies maintenance. Available in bore sizes 32mm to 100mm. All series types are available with auto switch capability
CH2 double acting hydraulic cylinders conform to JIS B 8367 specifications. Surge pressure generated when running into the cushion has been reduced by 30% or more compared to the CH series, due to the CH2s cushion seal system. Separate construction of the rod cover simplifies maintenance. Available in bore sizes 32mm to 100mm. All series types are available with auto switch capability with