L d l D m d H B C IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 NT-02 NT-03 NT-04 NT-05 NT-08 NT-10 Type C 8 for axis 16.2 20.2 36.2 44.2 56.2 64.2 1.5 1.55 1.55 2.05 2.55 2.55 13 17 22 27 32 41 15.0 19.6 25.4 31.2 37.0 47.3 Type C 10 for axis Type C 10 for axis Type C 14 for axis Type C 18 for axis Type C 22 for axis 24 Series CLQ Compact Cylinder with Lock Double Acting, Single Rod Simple Joint
. * There is no S option for AC voltage valves because the generation of surge voltage is prevented by a rectifier. u Manual override H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector Nil Non-locking push type D Push-turn locking slotted type AC (50/60 Hz) CE-compliant 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] * LN and
B C D E F G H 148 206 246 Model MHL2-40D MHL2-40D1 MHL2-40D2 80 138 178 188 246 286 288 406 486 116 174 214 348 466 546 72 130 170 12-4-13
B () PLC 15ms(30ms) 61 - (+) (-) (JOG ) () (1-052) RESET (+) (-) B (1-096) RESET C 0 (1-097) RESET C 2,3: OFF (EMG ) OFF (1-098) RESET JOG ON (SVRE ON) EMG OFF DRV C DC24v DRIVE (1-099) RESET SETOFF DRV C 0: () 1: OFF 0: a 2: OFF B (1-103) 0: C RESET OFF ON 1: a 2,3: 2: OFF ON B 0 "0" 2 3 62 - () (1-106) RESET SVON C 1 (1-144) RESET SVON D ON (M24V
JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
C J G5-S Air-hydro Converter: CCT40 CV MVGQ 50 M32 x 2 Lube-plug CC Rc 1/4 Air port size RB J D-X 20Rc 1/4 Oil port size Data L Dimension (Effective oil level stroke) (mm) Effective oil level stroke (mm) 50 100 150 200 300 L 213.5 263.5 313.5 363.5 463.5 10-17-9 10 Valve Unit Series CCVS/CCVL How to Order CCV S 1 1 1 U1 Suffix S Single valve Valve unit size Unit for CC63 (Unit mounted to
P-D 1 P P C C G3 D (2) 1) G4 5m (1) 1.
HRZ Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) HRZD Specifications HRW Model HRS100-Wl-20-l HRS150-Wl-20-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.23 1.33 Control method PID control Ambient temperature Note 1) C 2 to 45 HECR HEC Circulating fluid Note 2) Tap water, 15% ethylene glycol aqueous solution, Deionized
Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4). 108 108 AIR VENT M6 x P1 G1/2 AIR VENT M6 x P1 2 x RcD 2 x RcD C B A B OUT IN OUT IN C A DRAIN G1/4 DRAIN G1/4 (mm) (mm) A B D C A B D C Model Element length Model Element length A (L250) A (L250) 314 70 374 314 70 407 FGDC FGDE FGDC FGDE B (L500) B (L500)
Q = qm x C x (T2 T1) x qv x C X T 1 x 35 x 4.186 x 103 x 3.0 60 = = 60 qm x C x (T2 T1) 860 Q = = 7325 [J/s] 7325 [W] = 7.3 [kW] x qv x 60 x C x T = Cooling capacity = Considering a safety factor of 20%, 7.3 [kW] x 1.2 = 860 8.8 [kW] 1 x 35 x 60 x 1.0 x 103 x 3.0 860 = Thermo-chiller qv: Circulating fluid flow rate Q: Heat generation amount T2: Return temperature Users equipment 7325
Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) Specifications Model HRSH090-Al-20-l HRSH090-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) (GWP1975) Refrigerant charge kg 1.32 Control method PID control Ambient temperature/humidity Note 1), 9) C/% 5 to 45/30 to 70% Circulating fluid Note 2) Tap water, 15%
0.5 0.6 0.7 F 200 V Black COM (0 V) G Shield Data A phase output pulse Connector pin arrangement B phase output pulse G A F B H E D C 0 1 2 3 4 3 2 1 Counter value 10-12-55
Materials: 12, 20 Steel 32 to 63 Rolled steel 30 d (mm) Bore (mm) D C H d B C D Part No.
D) In the state of C), adjust shim w so that the arm side block contacts the workpiece.
Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the
Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800
Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.
L 285.5 21 273 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 Fitting blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 L A Dimensions (mm) Applicable fitting d Part number A L D D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32
C Locking type (Manual) VK 1 100 VAC, 50/60 Hz Electrical entry 2 200 VAC, 50/60 Hz 3110 VAC, 50/60 Hz 4220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC VZ L: L plug connector, With lead wire LN: L plug connector, Without lead wire LO: L plug connector, Without connector D: DIN terminal G: Grommet, Lead wire length 300 mm Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080