SMC Corporation of America
Elite Part Number Search
Search Results "AS2210-01-N-J"

Filter Regulator AW30, 40 Related Equipment How to Order Integration of a filter and regulator allows simple wiring. 03 BE 30 1N AW F Optional specifications Filter regulator Applicable models AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 Symbol 1 2 6 8 J N R W Z Contents 0.02 to 0.2MPa setting Metal bowl Nylon bowl Metal bowl with level gauge Drain guide

23.1 16 27.1 12.7 20.4 14.3 31.1 36.1 27.5 3.2 9.3 1/4" 12 12 32.1 13.5 R 1/8 AS221FG-01-04 AS221FG-N01-01 12.7 20.4 27.5 4 9.3 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 13.5 20.4 13.4 27.5 6 11.6 5/32" 14.2 13.4 27.1 30.2 35.2 12 32.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 23.1 12.7 30.2 19 18.5 35.2 25.3 32.1 30.2 32.4 8 15.2 3/16" 11.4 27.1 16.5 14.2 AS221FG-01

Note 2) The material of the lock nut option-J (round type) is brass. However, note that only the AS221F uses steel. Note 3) The surface treatment of the lock nut option-J (round type) is electroless nickel plated. NBR, Stainless steel Note 1) Only AS221F-U01 and AS321F-U02 are electroless nickel plated. Note 2) The material of the lock nut option-J (round type) is brass.

Alarm_Co mment_1 11 (01-111) 6F C RESET Input The motor speed exceeds a specific level due to an external force, etc. Speed exceeded set value (01-144) Make improvements so that the motor speed will not exceed the maximum speed of the actuator.

23.1 16 27.1 12.7 20.4 14.3 31.1 36.1 27.5 3.2 9.3 1/4" 12 12 32.1 13.5 R 1/8 AS221FG-01-04 AS221FG-N01-01 12.7 20.4 27.5 4 9.3 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 13.5 20.4 13.4 27.5 6 11.6 5/32" 14.2 13.4 27.1 30.2 35.2 12 32.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 23.1 12.7 30.2 19 18.5 35.2 25.3 32.1 30.2 32.4 8 15.2 3/16" 11.4 27.1 16.5 14.2 AS221FG-01

The station No. of CC-Link is shown. (01 to 64) Set the CC-Link communication speed. STATION NO. Switch name Set range Description STATION NO. (X10) Set upper bits of the station. 01 to 64 STATION NO. (X1) Set lower bits of the station. The CC-Link address setting at the time of the factory shipment is set in 01".

-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -02-08 AS2200-02 100 200 50 100 0

J When J is selected for e, install the release valve or vacuum breaker in the middle of the vacuum piping.

32 100 D Standard Type With Auto Switch CDNG L N 32 100 D B53 Number of auto switches With auto switch (with magnet) 2 pcs.

(kg) -E 0.21 0.21 0.21 -EL 0.26 0.26 0.26 -M 0.27 0.27 0.27 -ML 0.32 0.32 0.32 Without switch 0.17 0.17 0.17 Model ZM2 ZM4 ZM6 ZM1-J ZM3-J ZM5-J ZM1-K ZM3-K ZM5-K ZM1-A ZM3-A ZM5-A ZM1-B ZM3-B ZM5-B ZM0.24 0.28 0.33 0.34 0.39 0.25 0.29 0.34 0.35 0.4 0.25 0.29 0.34 0.35 0.4 0.26 0.3 0.35 0.36 0.41 P Q 0.24 0.28 0.33 0.34 0.39 -04R/L 0.209 0.214 0.219 0.224 0.229 0.234 0.239 0.244 0.249 0.254

(n 2) 2 20 + 35 55 + 35 (n 2) (n = 2, 3, 4, 5) D-M9 5 20 CHQ 55 (n = 2, 4, 6) Note 3) (n 2) 2 55 + 35 (n 2) (n = 2, 3, 4, 5) 20 + 35 D-M9W 10 20 55 CHK (n = 2, 4, 6) Note 3) (n 2) 2 60 + 35 (n 2) (n = 2, 3, 4, 5) 25 + 35 D-M9A 10 25 60 CHN (n = 2, 4, 6) Note 3) (n 2) 2 50 + 35 (n 2) (n = 2, 3, 4, 5) 15 + 35 D-A9 5 15 50 CHM CHM (n = 2, 4, 6) Note 3) (n 2) 2 35 + 35 (n 2) (n = 2,

C J G5-S CV MVGQ Applicable cable (Heavy-duty cord) Applicable to cable O.D. of 6.8 to 11.5.

SW 40 SW 20 SW 10 SW 08 SW 04 SW 02 SW 01 Rat e BS4 BS2 BS1 0 O FF O FF O FF O FF O FF O FF O FF 0( 156kbps) O FF O FF O FF 1 O FF O FF O FF O FF O FF O FF O N 1( 625kbps) O FF O FF O N 2 O FF O FF O FF O FF O FF O N O FF 2( 2. 5M bps) O FF O N O FF : : : : : : : 3( 5. 0M bps) O FF O N O N 64 O N O N O FF O FF O N O FF O FF 4( 10M bps) O N O FF O FF D i gi t of 10 D i gi t of 1 Setting

With rod boot Nil None Cushion type J Rod boot Nylon tarpaulin Bore size N Non-lube/Rubber bumper K Heat resistant tarpaulin 20 A 20 mm Non-lube/Air cushion When equipped with rod boot, foot and rod side flange type brackets are attached before shipment. 25 25 mm 32 32 mm Built-in Magnet Cylinder Model Cylinder stroke (mm) 40 40 mm Refer to Standard Stroke on page 9-5-9.

Stop Method Mode After StopParameter When Enabled Classification ping n.00 [Factory setting] DB Coast n.01 Pn001 After restart Setup n.02 Coast Zero clamp n.1 Deceleration to a stop n.2 Coast A servomotor under torque control cannot be decelerated to a stop. The servomotor is stopped with the dynamic braking (DB) or coasts to a stop according to the setting of Pn001.0.

PNP 1~5 V F PNP 4~20 mA G NPN H PNP J 1~5 V 1~5 V K 4~20 mA 4~20 mA OUT2 C (1) T V + (2m) N M L/min L G gal/min gal F gal/min gal J L/min L GFJ : 1[L/min]0.2642[gal/min] 1[gal/min]3.785[L/min] []=9/5[]+32 15 V PF3W5--1(T) -9No.PF-OMN0011CN-C C (1 ) T V -10No.PF-OMN0011CN-C / ZS-26-B ZS-26-C ZS-26-01 ZS-40-W 2 m (e-con) ZS-28-CA-4 1 ZS-40-Y 10 -11No.PF-OMN0011CN-C

+ L17 x 2 L8 x n + L16 x 2 L8 x n + L25 x 2 L8 L8 1 Refer to page 618 for L8. 2 The above figure shows the manifold with controllers connected using two L-brackets and a threaded stud kit for manifold.

32 100 D Standard Type With Auto Switch CDNG L N 32 100 D B53 Number of auto switches With auto switch (with magnet) 2 pcs.

pcs. + 4 x (n pcs. 1) 36 0.3 36 0.3 4 x R3 or less 4 x R3 or less 67 or more Panel thickness 1 to 5 mm Note) This is the minimum value for the piping method 01 or N01.