Metric sizes Inch sizes Body Class Type LQ-GP J PAX 3 03 03 10 10 10 12 12 12 19 19 19 25 25 1/8" 03 03 03 03 3/16" 05 05 1/4" 07 07 07 3/8" 11 11 1/2" 13 13 3/4" 19 19 1" 25 4 04 04 04 04 6 06 06 06 8 08 Insert pin holder assembly (with the parts case) Type Insert pin/ Holder type 1 2 1 2 3 4 5 6 J PB Insert pin material (J/K type only) Nil N Metric sizes Inch sizes Nil S Resin
Note 5) Refer to cautions on page 9 if IZN10E-11-(Female threads for piping) is used.
Fig. (2) Note) When there are 10 or fewer manifold block assemblies, and more are added to make a total of 11 or more, a supply/exhaust block assembly must also be added. Hook this part onto the DIN rail, and press down in the direction of the arrow.
10 10 12 14 20 Note) M5 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 Note) Note) 3 Body ported 5 1 1 11 4 7 1 4 11 2 1 2 2 9 Note) Only bracket or foot may be mounted. 14-10-2 E-P HYREG Series VY1 Standard Specifications 02 03 04 04 06 10 02 03 04 VY1A0 0 1-M5 VY1B0 0 1M 0 5 1 VY110 0 10 0 1 2 VY120 0 10 0 1 2 VY130 0 1VY140 0 1VY150 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 Model VY1D00-M5 10 M5 01 M5 Port
Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 AS2301F-06 AN110-01 Series MB/CA2 Series CJ2 Series CM2 Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AN200-02 AN3301F-06 AS1301F-06 6 x 1 m AS3001F-06 SYJ7120-01
KFN-04 KFN-06 KFW-04 KFW-06 KFV-04 KFV-06 KFS-04 KFS-06 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.
With One-touch fitting Port size U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 Needle Valve/Flow Rate Characteristics AS2201F-U02, AS2211F-U02 AS2301F-U02, AS2311F-U02 AS2201F-U01, AS2211F-U01 AS2301F-U01, AS2311F-U01 600 300 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 06, 07 200 400 01, 23 300
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
Power supply connector POWER Connector (e-con) IZS41, IZS42 7 8 12 13 9 1 2 3 4 5 10 11 14 6 Operation NO.
10 1/4 3/8 1/2 3/4 1 Location and size of A, B port 02 03 04 06 10 02B 03B 04B Side 1/4 Side 3/8 Side 1/2 Side 3/4 SIde 1 Bottom 1/4 Bottom 3/8 Bottom 1/2 Option Nil TBU SU W None With terminal box With SI unit Splash proof 3-11-18
Direct Operated Pilot Operated Refer to pages 7, 9, 11, 25, 35, and 39 for details. 2-Port Solenoid Valve Improved environmental resistance due to the stainless steel coil cover [IP67 enclosure] Refer to pages 46 to 50 for details.
Conduit terminal: VP3185-T A B DIN terminal: VP3185-D A B Conduit terminal with indicator light (TL) Light Light position Max. 11 Applicable cable 6 to 12 [ ]: With indicator light (TL) 1500 Made to Order: Series VP3145/3165/3185 Main Valve Double Acting Type: -X80/X81 How to Order 1 D Z A N X 06 5 1 4 VP31 81 CE-compliant Body size CE-compliant Nil 4 6 8 1 2 Q Electrical entry: D/DO only
: D VXA 59 47 Cable 6 to 12 VN LVC LVA LVH (2.3) (7.5) (5.5) 34.5 (44) 80 86 LVD 63 69 (33) 36 (27) 30 LVQ G 1/2 IN 11 14 22 OUT LQ Hexagon width across flats Bracket 24 26 50 (52) (28) 2-Rc1 /4, 3/8, 1/2 22 28 LVN 40 (67) TI/ TIL Conduit terminal: T PA 92 2 PAX PB (2.3) 98 104 (7.5) (5.5) 25 52 55 (33) 36 G 1/2 (27) 30 (27) 30 11 14 IN OUT Bracket 50 (52) (67) 24 26 (28) 2-Rc 1/4, 3/8, 1
-B 3 70.8 3/4 30.4 50 1/8 54 8 75 44 55.5 93.2 8.5 35.8 10.5 33.8 70 M42 x 1.5 2.3 33.8 37 42.5 21 7 10-/21-AR50K-B 3.2 80.3 3/4, 1 40 70 1/8 66 7 90 65.8 44 125.2 11 43 13 43.3 90 3.2 43.3 10-/21-AR60K-B 3.2 80.3 1 44.5 70 1/8 4.5 66 95 65.8 44 129.6 11 46 13 43.3 90 3.2 43.3 Note 1) The dimension of B is the length when the filter regulator knob is unlocked.
IN side, OUT side 4 10 20 30 50 75 75 Weight (g) 22 22 30 30 39 39 Model Tubing size ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 7 7 12 12 16 16 Unrestricted 360 piping tube mounting on the IN side 6 6 8 8 10 Metric size Easily replaced filter element Easy installation and removal with One-touch fittings ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 22 22 30 40 62 20 20
Reload I/O Devices : The display above shows an example of the software configuration structure of the EX600 series. : Allocate the diagnostic data to Module 11 when its setting is other than the diagnostic mode 0.
N-04 N-06 L-04 L-06 S-04 S-06 LL-04 LL-06 4 6 N-08 8 N-10 10 N-12 12 4 6 L-08 8 L-10 10 L-12 12 4 6 S-08 8 S-10 10 S-12 12 4 6 LL-08 8 LL-10 10 LL-12 12 Precautions Be sure to read before handling.
No.ZL3-OM00601-B 1.How to Order ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 Without valve ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 With valve Pressure switch ZL3 M 06 1 K1 5 LO Z 1 V A M W 1 with energy saving function 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 1) Max. suction flow 2) Standard supply pressure 4) Exhaust specifications 3 300L/min(ANR) M 0.35MPa Nil Exhaust through silencer H 0.50MPa