SMC Corporation of America
Elite Part Number Search
Search Results "11-MXJ8-10CS-M9N"

MY1B40 26.5 Rc1/8 80 35 70 10 16 8 51 16 10 16 28.5 12 20 55 280 Rc1/16 264 48 16 11 32 40 Rc1/4 100 85 12 18.5 9 59 23.5 14 20 35 14 67 340 Rc1/8 40 23.5 322 60.5 24 12 35 47 Port Variations Bottom Ported MY1BG Y Y Head cover piping connection can be freely selected to best suit different piping conditions.

Lead wire length (m) Auto switch model MHC Electrical entry direction Load voltage Pre-wired connector Applicable load 5 (Z) Type Electrical entry Special function Indicator light Wiring (Output) 0.5 (Nil) 1 (M) 3 (L) DC AC Perpendicular In-line MHT M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire(NPN) IC circuit 5 V, 12 V 12 V 3-wire(PNP) Solid state auto switch MHY

For details, refer to page 8-30-31. 8-3-11

For details, refer to page 8-30-31. 8-3-11

(s P. 11 ) (2) The weight of a transferred object and transfer speed should be within the allowable range as shown in the graphs. (3) Overhang L3 should be 30 mm or less. V m L3 30 mm Caution (1) If a load is applied in the direction as shown on the right side, an eccentric load will be applied to the guide.

The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches. GUIDED CYLINDER. Cylinder

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SLIDE TABLE, CLEAN ROOM, ACTUATOR, MXS/MXJ GUIDED CYLINDER, D5, 8MM MXJ/MXS CLEAN-ROOM, .31439 lb

(Product with a lead wire length of 0.5 m is not available.) 18 Prior to Use Auto Switches Common Specifications 2 Refer to the Auto Switch Precautions on pages 8 to 11 before using auto switches. Meaning Term Hysteresis A deviation amount between the ON position and OFF position caused by auto switch characteristics (difference in sensitivity between ON and OFF).

M3 3B = M3E/M3E max = 1.8/10 = 0.18 L2 M3E m x g FE From above, n = 1 + 2a + 2b + 3A + 3B = 0.25 + 0.105 + 0.084 + 0.225 + 0.18 = 0.844 From n = 0.844 1, it is applicable. 8-16-10 10 MX MTS MY CY MG CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless cyinder, low profile guide type Nil S n 2 pcs. 1 pc. n pcs

No.MH*-OMZ0004 / / JMHZ2-16D-X7400B-ASSISTA(-P) . 2 1. 4 2. . 5 3. . 6 3-1. . 6 3-2. . 7 3-3. . 8 3-4. () . 9 3-5. . 10 3-6. . 10 4. . 11 4-1. . 11 4-2. 3 . 12 4-3. . 13 5. . 14 5-1 . 14 5-2. . 14 5-3. . 20 5-4. . 20 5-5. . 20 5-6. . 21 6. . 21 1 - (ISO/IEC)(JIS)*1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power

DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) A 9 13 11 13.5 B 6 8.5 11.5 14.5 A 9.5 13.5 11.5 14 B 6.5 9 12 15 A 6.5 10.5 8.5 11 B 3.5 6 9 12 C 8 12 10 12.5 D 5 7.5 10.5 13.5 C 12 16 14 16.5 D 9 11.5 14.5 17.5 C 11 15 13 15.5 D 8 10.5 13.5 16.5 32

DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 3.5 6 9 12 A 6.5 10.5 8.5 11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32

Connector and pin layout . 11 3-6. Center of gravity .12 4.Product Specifications .13 4-1.Magnet Gripper .13 4-2. 3-port solenoid valve .14 4-3. Auto switch .15 5.Operating method or operation .16 5-1Precautions for Design .16 5-2. Installation .17 5-3. Air supply .22 5-4. Piping .22 5-5. Operating environment .23 5-6. Lubrication .23 6. Maintenance or inspection .23 6-1.

Auto switch model Lead wire length (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Indicator light Electrical entry Type Special function Perpendicular In-line 0.5 (Nil) 1 (M) 5 (Z) 3 (L) M9N M9P M9B M9NW M9PW M9BW M9NA1 M9PA1 M9BA1 P3DWA M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire

CY1S Auto switch model Lead wire length (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Indicator light Electrical entry Type Special function 3 (L) Perpendicular In-line 0.5 (Nil) 5 (Z) 1 (M) CY1L M9N M9P M9B M9NW M9PW M9BW M9NA1 M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2

JMHZ2-16D-X7400B-HC10-(*) P13P14P15 4 M6 31.5 2XM4x0.7 8 4 M6 108.8L 4 4 M4 4 M3 27 17 10 - JMHZ2-16D-X7400B-HC10DT-(*) 4 M6 32.5 8 4 M6 109.8L 4 4 M4 4 M3 27 17 11 - 3-6. M8 8 M8-Molex P .19 NPN PNP No. 1 +24V DC24V 2 GND DC0V 3 ON/OFF() 4 ON/OFF() 5 () 6 () 7 8 Molex (51227-0800) M8 8 12 - 3-7.

Load voltage Pre-wired connector Applicable load DC AC Auto switch model Lead wire length (m) Indicator light Electrical entry Wiring (Output) Type Special function 1 (M) Perpendicular In-line 0.5 (Nil) 5 (Z) 3 (L) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 M9N M9P M9B M9NW M9PW M9BW M9NA1 IC circuit 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP)

Please perform a holding test referring to the value selected based on the graph. 11 - 3-4. Dimensions Refer to P17, P18 and P19 for the dimensions of the magnet gripper, valves and auto switches. 3-4-1.MHM-25D-X7400A-DTP-(N/P) 12 - 3-4-2.MHM-25D-X7400A-HC10DT 13 - 3-4-3.MHM-25D-X7400A-HC10 14 - 3-5. Connector and pin layout Attached cable is fixed to the product.