Your search for ZSE20 returned 30 result(s)
There were no hits with the full part number, but there were 56 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 120 lb
ZSE20C 0 to 101 kPa ZSE20CF 100 to 100 kPa Symbol Description R NPN open collector 2 outputs + Analog voltage output*1 S NPN open collector 2 outputs + Analog current output*1 T PNP open collector 2 outputs + Analog voltage output*1 V PNP open collector 2 outputs + Analog current output*1 X NPN open collector 2 outputs + Copy function Y PNP open collector 2 outputs + Copy function Symbol
ZSE20C 0.0~-101.0 kPa K ZSE20CF -100.0~100.0 kPa T ISE20CH -0.100~2.000 MPa 24 X NPN2 A1 A Y PNP2 A3 C R NPN2+1 B T PNP2+1 E S NPN2+1 D + V PNP2+1 1: F + 4 2 M SI3 1 P psi2 2 3 kPaMpa (2m ) W 2 R1/4 C01 Rc1/8 N02 NPT1/4 A2 URJ1/4 L F02 G1/4 B2 TSJ1/4 2 2 () L() A A1 ZS-46-A1 C A3 ZS-46-E B ZS-46-B E ZS-35-B D ZS-46-D + F ZS-35-E -9No.PS-OMU0008CN-D / A ZS-46-A1
Selectable option for manifold (Refer to i on pages 11 and 12, and y on page 13.)
-5No.PS-OMM0002CN-F SUS630SUS304 () * (14 ) FG (49 N () () TSJSwagelok(Swagelok URJ Swagelok(VCR)/GroundGround Swagelok,VCRSwagelok Company -6No.PS-OMM0002CN-F * 6 33 () () 10m DC(-)() * ( ) () CE -7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y
() M8(3 ) * 6 33 () () 10m DC(-)() ( ) -6No.PS-OMM0006CN-E * ( ) () CE CE -550 (5 ) * ON , 1015 10 /1 2351 LCD -7No.PS-OMM0006CN-E * -8No.PS-OMM0006CN-E (M8(3 )11 ) 01 X M ISE40A 2 K ISE40A -0.11.000 MPa ZSE40A 0.0-101.3 kPa ZSE40AF -100.0100 kPa 1 01 R1/8 (M5) A A N01 NPT1/8 (M5) W1 Rc1/8 B B WF1 G1/81 D D M5 M5X0.8 () E C4 4 C6 6 F + 1IS0228-1 P10/1 X NPN2() Y
-2No.PS-OMS0006CN-G / *3) 1 1.5 3) 1 1 -3No.PS-OMS0006CN-G () () () () -4No.PS-OMS0006CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMS0006CN-G * FG (35 N () ,() *() 6 33 () () 30m DC(-)() * -6No.PS-OMS0006CN-G ( ) () CE/UKCA -5~50(5 ) * , 1015 10 1% 2053 LCD * -7No.PS-OMS0006CN-G N M5 ISE20 3 ISE20 -0.1001.000 MPa Y ZSE20 0.0-101.0 kPa K ZSE20F
1.5 3) 3) 1 1 () [] -3No.PS-OML0002CN-G () () () () -4No.PS-OML0002CN-G () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL (100 10 ) JIS B 8392-1 11.1.21.6.2:2003 () -5No.PS-OML0002CN-G * / / ,FG (35N ) () () * () 6 33 () () 10 m DC(-)() () * -6No.PS-OML0002CN-G ( ) () CE 050(5), * ON , 1015 10 /1 2146 LCD * -7No.PS-OML0002CN-G 01 N ISE30A 3 ISE30A -0.11 MPa Y
Current pressure value (Main display) Output mode Hysteresis mode Item (Sub display (left)) Set value or peak/bottom value (Sub display (right)) Reversed output Normal output [F 0] Units selection function ISE20C: 0.500 MPa/ZSE20C: -50.5 kPa/ ZSE20CF: 50.0 kPa/ISE20CH: 1.000 MPa Default setting Units specification Pressure range Pressure setting Sub display In measurement mode, the display
Bracket C Units specification Pressure range Default setting ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa Hysteresis ISE20C(H) MPa Self tapping screws: Nominal size 3 x 8L "Nil" or M Self tapping screws: Nominal size 3 x 10L ZSE20C(F) kPa Delay time 0.00 sec.
ZSE20C is vacuum rated, while the ZSE20CF is rated for both vacuum and a low positive pressure range. Each model in the ZSE20 family offers a 3-screen, 3-color display. The main screen shows the curent measured value in red or green, while two sub-screens can display the setting label and its numeric value in orange.
cm 2 bar psi MPa kgf/cm 2 bar psi LCD () () () () kPa MPa 3 1)OUT1 2)OUT2OUT1(CH1) OUT1 -19No.PS-OMH0005CN-D : : : : 2 digits 3 digits7 digits 7 digits -20No.PS-OMH0005CN-D 4 [ms] 5 -21No.PS-OMH0005CN-D 1OUT1P_1 P_1n_1 2OUT1P_2 P_2n_2 3OUT2P_3P_4(CH1) 12 4 C_5(CH24 C_3) -22No.PS-OMH0005CN-D 1OUT1 AP1 2OUT1 OUT1 3OUT1 A1L (OUT1 1 AP2 4OUT2 (CH1) AP2 5OUT2 OUT2 OUT1 OUT2 A2L
After [A2L] is displayed and measurement starts, when the pressure change is detected, a set value will appear automatically. (When OUT2 setting is not necessary, press the and buttons simultaneously for 1 second or more to return to measurement mode). Initial Setting Troubleshooting Warning Auto-preset is being set Error Indication Initial setting is required for each channel.