SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20B-L-M5-WK"

[F 0] Units selection function Page 31 Units specification Pressure range Default setting ISE20B MPa "Nil" or M ZSE20B(F) kPa ISE20B P psi ZSE20B(F) [F 1] Setting of OUT1 Page 32 Item Explanation Default setting Output mode Either hysteresis mode, window comparator mode, error output or output off can be selected.

Before Use Digital Pressure Switch ZSE20B(F)-L/ISE20B-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.

ZSE20B(F)-L is a digital vacuum sensor with IO-Link communication protocol support.  When paired with an IO-Link master, measured values, and settings can be accessed from the HMI screen of a PLC.  ZSE20B(F)-L incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit and 13 bits for the measured value. 

(F) kPa P ISE20B psi ZSE20B(F) [F 1] OUT1 32 OFF ONOFF ISE20B 0.500 MPa ZSE20B -50.5 kPa ZSE20BF50.0 kPa ISE20B0.050 MPa ZSE20B 5.1 kPa ZSE20BF5.0 kPa 1.5ms OUT1 ON OUT1 OFF -29No.PS-OMU0005CN-C [F 2] OUT2 35 [F 1]OUT1 [F 3] 37 0 ms [F 4] 38 [F 5] FUNC 40 [F 6] 42 0% [F10] 43 std() [F11] 49 1000 [F80] 50 OFF [F81] 51 OFF [F82] 53 A [F90] 54 OFF [F96] 56 [F97] 57 OFF

s NVZ3000 Symbol With Subplate Body porled Vpe Base mounted type with subplate NVZ3r20 NVZ340 Cv0.25 1 1 / l \ l h u d l / l \ L E l ff NVZ32?

MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: Operation

Bracket mounting inserts found on the standard ZSE20B(F) are omitted as well.  25A-ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

The ZSE20B(F)-S is a digital vacuum sensor with all standard features of the ZSE20B(F), while integrating an M12 connection. M12 permits a stable connection for sensor installations outside a cabinet. The sensor has an informative, easy to read 3 screen, 3 color display.