Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual:

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. VACUUM SWITCH, ZSE30, ZSE30A. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 61.00000 lb. N63.

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 61.00000 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 61 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. VACUUM SWITCH, ZSE30, ZSE30A. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 61.00000 lb. N63.

X For vacuum/ compound pressure ZSE20A X M M5 q w e r t y u q Rated pressure range w Output specification e Unit specification ZSE20A 0 to 101 kPa ZSE20AF 100 to 100 kPa Symbol Description R NPN open collector 2 outputs + Analog voltage output*1 S NPN open collector 2 outputs + Analog current output*1 T PNP open collector 2 outputs + Analog voltage output*1 V PNP open collector 2 outputs

-100.0~100.0 kPa T 2 X NPN2 Y PNP2 R NPN2+1 T PNP2+1 A1 A S NPN2+1 V PNP2+1 1: A2 B M SI3 P psi2 2 3 kPaMpa B D + M5 M5 1 01 R1/8 N01 NPT1/8 C4H 4mm J (2m) C6H 6mm N7H 1/4 inch C4L 4mm C6L 6mm N7L 1/4 inch -8No.PS-OMU0002CN-D / A ZS-46-A1 38L(2 ) B ZS-46-A2 38L(2 ) ZS-46-B + ZS-46-D ZS-46-5L 5 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch

The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body.

Compared to the ZSE20, the ZSE20AF adds a 2nd switch output, as well as an analog output, either voltage or current.  ZSE20A is vacuum rated, while the ZSE20AF is rated for vacuum and a low positive pressure range.  Each model in the ZSE20 family offers a 2-screen, 3-color display.  The main screen shows the current measured numeric value in orange. 

Compared to the ZSE20, the ZSE20AF adds a 2nd switch output, as well as an analog output, either voltage or current.  ZSE20A is vacuum rated, while the ZSE20AF is rated for vacuum and a low positive pressure range.  Each model in the ZSE20 family offers a 2-screen, 3-color display.  The main screen shows the current measured numeric value in orange.