There were no hits with the full part number, but there were 56 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Straight Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Straight Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Straight Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 65.00000 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 65.00000 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 65 lb
ZSE20A() ZSE20AF() ISE20A() 3 MPa,kPa,kgf/cm 2,bar,psi,InHg,mmHg MPa,kPa,kgf/cm 2, bar,psi LCD 3 (X2) 1)/ 2) 1)4 7 2)4 (1 11 7 ) ON OUT1OUT2 4 0,10,50,100,500,1000,5000 ms IP40 AC1000 V 1 50 M(DC500 V ) -550 -1060 () 3585RH() UL/CSA(E216656)CE(EMC RoHS ) 2 m 1(0 ms) 2 3MPa/kPa 490% 5 -76No.PS-OMU0002CN-D M5 01 N01 C4H C6H N7H C4L C6L N7L M5X0.8 R1/8 NPT1/8 4 mm 6 mm 1/4 inch
Load impedance Maximum load impedance at power supply voltage of 12 V: 300 at power supply voltage of 24 V: 600 Minimum load impedance: 50 Input type Non-voltage input: 0.4 V or less Input mode Select from Auto-shift or Auto-shift zero.
Bracket B MPa ISE20A ISE20A: 0.050 MPa/ZSE20A: 5.1 kPa/ ZSE20AF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20A(F) Safety Instructions ISE20A Delay time 1.5 ms or less Mounting with panel mount adapter Mount part (a) to the front of the body and fix it. Then insert the body with (a) into the panel until (a) comes into contact with the panel front surface.
Bracket mounting inserts found on the standard ZSE20A are omitted as well. 25A-ZSE20A(F) is UL/CSA, CE and RoHS compliant, with an IP40 enclosure rating.
Bracket mounting inserts found on the standard ZSE20A are omitted as well. 25A-ZSE20A(F) is UL/CSA, CE and RoHS compliant, with an IP40 enclosure rating.
ON/OFF 2 7 "8"7 "-"()7 digit() 1digit=1 kPa 1,2,3,,99,100 1 kPa 1 5[V]F.S.=514[V] 1F.S.40.010.04[V] F.S. () NPN()() NPN PNP()() PNP R.D. 1.000 5R.D.1.000 50.05 0.800 5R.D.0.800 50.04 ON OFF (29 ) ON OFF Hysteresis ON-OFF /, () () 25[]ON-OFF (copy function) () NPN () () ()()( ) () -11No.PS-OML0002CN-G ON ON 0 (1 k 1 M A/D 5 V A/D 5(V)1(M)/(1(K)+1(M)) 4.995(V)0.555 V ) 29 ON-OFF
Hysteresis mode Window comparator mode Hysteresis Variable (0 or above) Note 1) 0.6 to 5 V 2.5% F.S. 1 to 5V 2.5% F.S.
() 1 V (80 mA ) 1 1.5ms (20,100,500,1000,2000,5000 ms ) 2 0 2, 2,bar,psi,InHg,mmHg MPa,kPa,kgf/cm 3 MPa,kPa,kgf/cm bar,psi LCD 3 (X2) 1)/ 2) 1)4 (7 ) 2)4 (1 11 7 ) ON OUT1 4 0,10,50,100,500,1000,5000 ms -62No.PS-OMS0006CN-G ZSE20() ZSE20F() ISE20() IP40 AC1000 V 1 50 M(DC500 V ) -550 -1060 () 3585RH() CE/UKCA UL/CSA(E216656) 2 m 1(0 ms) 2 3MPa/kPa 490 M5 01 N01 C4H C6H