SMC Corporation of America
Elite Part Number Search
Search Results "ZK2Q00K53HA-06-CKP"

M1 05 06 N5 N6 No pressure gauge Pressure gauge with MPa display (For odd number station) Pressure gauge with MPa display (For even number station) Note 2) Pressure gauge with psi display (For odd number station) Note 2) Pressure gauge with psi display (For even number station) SY 0M P 00 5 Series 5 7 SY5000 SY7000 Regulating port Part numbers of mounting screw (For repairs) SY3000: SY3000

Auto switch mounting band D-B54 BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) DNote 1) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform, methylamines, hydrochloric acid or sulfuric acid is splashed over, so it cannot be used. Please contact SMC regarding other chemicals.

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

CKP: built-in strong magnet type / with magnetic-field-resistant auto switch.· Magnetic-field-resistant 2-color indication solid state auto switch.· The auto switch mounting position is available from 3 directions.· Setting part no. for the model with speed controller reduces hassle of selecting and ordering.· "Clevis width" and "a, b dimensions" have common interchangeability with all

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System

System: Vacuum Pump System for Manifold, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Connector: Common Wiring, Plug-in for Manifold, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: with Pump System PE Port Female Thread, Individual

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female

For AC40D-B For AC40D-06-B Modular F.R.L.

CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 28 23.5 30 Piping adapter AC25, AC30 AF30, AR30, AW30 AL30, AFM30, AFD30, AWM30, AWD30 30 30 32 AC40 AF40, AR40, AW40 AL40, AFM40, AFD40 AWM40, AWD40 36 36 32 AC40-06, AF40-06, AR40-06, AW40-06 AL40-06, AFM40-06, AFD40-06 E500-06 44 40 32 3/4 E600-06 E600-10 3/4 1 AC50, AC55, AC60, AC50B

AW4000 AL4000, AFM4000, AFD4000 3/8 33 35 42.2 1/2 50 35 42.2 3/4 AC400-06 AF4000-06, AR4000-06, AW4000-06 AL4000-06, AFM4000-06, AFD4000-06 3/4 E50-06 36 44 46.2 To order piping adapter with bracket, the parts number as shown below.

/08)-(B5/B6/B8) ZPR-(04/06/08)-(A5/A6/A8) y t t Component Parts No.

YV Sizes 40-06, 50, and 60 have been added to the AC series. Sizes 40-06, 50, and 60 have been added to the AF, AR(K), and AL. The VHS40-06 and 50 have been added. Size 40-06 has been added to the AFM/AFD. Sizes 40-06 and 60 have been added to the AW(K). Made to order options have been added. Number of pages has been increased from 104 to 112.

3/4 E500-06 3/4 32 40 44 AC40-06, AF40-06, AR40-06, AW40-06 AL40-06, AFM40-06, AFD40-06 E600-06 3/4 35 48 53 AC50, AC55, AC60, AC50B, AC55B, AC60B AF50, AR50, AL50, AF60, AR60, AL60 E600-10 1 Notes) in model numbers indicates a thread type.

AF20 AR20 AFM20 PPA 1/4, 3/8 AC25C AF30 AR25 AFM30 AL 1/4, 3/8 AC30C AF30 AR30 AFM30 1/4, 3/8, 1/2 AC40C AF40 AR40 AFM40 3/4 AC40C-06 AF40-06 AR40-06 AFM40-06 AW + AFM AC20D 1/8, 1/4 AW20 AFM20 AC30D 1/4, 3/8 AW30 AFM30 AC40D 1/4, 3/8, 1/2 AW40 AFM40 AC40D-06 3/4 AW40-06 AFM40-06 Table of Contents F.R.L.

A AF20-A AF30-A Air Filter AF40-A P.43 AF40-06-A AF50-A AF60-A AFM AFM20-A P.55 AFM30-A Mist Separator AFM40-A AFM40-06-A AFD AFD20-A Micro Mist Separator P.55 AFD30-A AFD40-A AFD40-06-A AR AR10-A AR20-B AR25-B Regulator AR30-B P.64 AR40-B AR40-06-B AR50-B AR60-B ARlK AR20K-B Regulator with Backflow Function AR25K-B AR30K-B AR40K-B P.67 AR40K-06-B AR50K-B AR60K-B 3 A Modular F.R.L.