SMC Corporation of America
Elite Part Number Search
Search Results "ZH15DLA-09-11-11N"

Nozzle Diameter: ø1.5mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: One-touch Fitting ø5/16", VAC: One-touch Fitting ø3/8", EXH: One-touch Fitting ø3/8", Accessories: w/o Standard Bracket, w/Silencer

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.

VF KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 VP4 VQ 1/2 VQ 4/5 Port plug VVQ1000-58A VQC 1/2 VQC 1/2 The plug is used to block the cylinder port.

KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.

Purchasing order is available in units of 10 pieces. d d KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.

Cylinder port is located at U side of body. 1(P) SUP port 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread P = 11 2-C6 3(R) EXH port Dimensions 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Formula L1 = 11n + 15.5, L2 = 11n + 60 n: Station (Maximum 16 stations) L n L1 L2 (L3) (L4) 191.5 236 262.5 273 180.5 225 250 260.5 169.5 214

Cylinder port is located at U side of body. 1(P) SUP port 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread P = 11 2-C6 3(R) EXH port Dimensions 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Formula L1 = 11n + 15.5, L2 = 11n + 60 n: Station (Maximum 16 stations) L n L1 L2 (L3) (L4) 26.5 71 100 110.5 37.5 82 100 110.5 48.5 93 112.5

VS7-6-FG-S AXT500-12-2 VFS3000-17-2 AXT500-13 AXT500-13 AXT500-13 AXT503-35 AXT503-35 AXT503-35 AXT503-12-1 AXT503-12-1 AXT503-12-1 MY-11N MY-11N MY-11N Description No.

Nozzle Diameter: 15 (ø1.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 09 (One-touch Fitting ø5/16"), VAC: 11 (One-touch Fitting ø3/8"), EXH: 11 (One-touch Fitting ø3/8")

Nozzle Diameter: ø1.5mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: One-touch Fitting ø5/16", VAC: One-touch Fitting ø3/8", EXH: One-touch Fitting ø3/8", Accessories: -

() (+) 19 30 Station 10 () (+) 20 SOL.A SOL.B () (+) 21 Station 11 () (+) 22 2 1 17 16 15 14 Terminal no.

SOL.A () () (+) (+) 15 13 6 stations SOL.B SOL.A () () (+) (+) 11 9 7 stations SOL.B Connector terminal no.

(A, B port) Applicable tubing O.D.: 3.2, 4, 6 45.5 2.5 SQ 10.5 (5) Formula L1 = 11n + 20 n: Station (Maximum 24 stations) 21.5 Dimensions VFS L n 1 7.5 2 3 4 5 6 7 8 11 9 10 12 29 L1 L2 L3 18 31 42 53 64 75 86 97 108 141 119 130 152 VFR 50 62.5 75 87.5 100 112.5 125 125 162.5 137.5 150 175 60.5 73 85.5 98 110.5 123 135.5 135.5 173 148 160.5 185.5 n L L1 L2 L3 13 14 16 17 18 21 22 24 VQ7

L dimension 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 285.5 21 273 No.

Ambient and fluid temperature Effective area (Cv) Max. operating frequency (1) Note 1) As per JISB83751981 (Supply pressure: 0.5MPa) Dimensions Single unit Manifold Dimensions Equation L1=11n+20 n: Station (Max. 24 stations) n L 1 2 3 4 5 6 7 8 9 10 11 12 42 62.5 73 L1 L2 L3 31 50 60.5 86 112.5 123 108 125 135.5 119 137.5 148 141 162.5 173 97 125 135.5 130 150 160.5 152 175 185.5 53 75 85.5

Dimensions Formulae L1 = 11n + 15.5 L2 = 11n + 55 n: Stations (max. 16 stations) L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 191.5 231 262.5 273 16 L1 L2 (L3 ) (L4 ) 26.5 66 87.5 98 37.5 77 100 110.5 48.5 88 112.5 123 59.5 99 125 135.5 70.5 110 137.5 148 81.5 121 150 160.5 92.5 132 162.5 173 103.5 143 162.5 173 114.5 154 175 185.5 125.5 165 187.5 198 136.5 176 200 210.5 147.5 187 212.5 223 158.5

Nozzle Diameter: 15 (ø1.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 09 (One-touch Fitting ø5/16"), VAC: 11 (One-touch Fitting ø3/8"), EXH: 11 (One-touch Fitting ø3/8"), Accessories: S (w/Standard Bracket, w/Silencer)

Nozzle Diameter: 15 (ø1.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 09 (One-touch Fitting ø5/16"), VAC: N03 (Screw-in NPT 3/8), EXH: 11 (One-touch Fitting ø3/8")

Nozzle Diameter: ø1.5mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: One-touch Fitting ø5/16", VAC: One-touch Fitting ø3/8", EXH: One-touch Fitting ø3/8", Accessories: w/Standard Bracket, w/Silencer