J 26 28 36 38 45 56 Model XLG-16 XLG-25 XLG-40 XLG-50 XLG-63 XLG-80 Model 12 11 11 11 11 39 63 68 69 96 39 63 68 69 96 XLG-50 XLG-63 88 95 110 Note 1) Dimension E applies when heater option is included.
50 121 48 27 12 40 26 44 21 XLG-40-2 65 171 66 39 11 55 41 67 29 XLG-50-2 70 181 79 31 11 75 52 76 29 9 XLG-63-2 88 206 100 39 11 87 95 70 77 33 9 XLG-80-2 90 244 117 46 11 114 110 83 104 39 9 *1 The E dimension applies when the heater option is included.
Model XLG-16 XLG-25 XLG-40 XLG-50-1 XLG-63-1 XLG-80-1 XLG-100-1 XLG-160-1 Flange (valve) size 16 25 40 50 63 80 100 160 Actuating type Double acting / pressurized to open/close Fluid Vacuum of inert gas Operating temperature oC 5 to 60 (5 to 150 for high temperature type) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-5 Conductance l/s Note 1 5 14 45 80 160 200 300 800 Internal
Flange Size: 25, Flange Type: KF(NW), Port Direction: L (Rear Flange Surface), Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 25, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 80, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 50, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 25, Flange Type: KF(NW), Port Direction: K (Left Flange Surface), Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 16, Flange Type: KF(NW), Port Direction: K (Left Flange Surface), Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 80, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -
Flange Size: 50, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -
Flange Size: 25, Flange Type: KF(NW), Port Direction: Left Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -
Flange Size: 16, Flange Type: KF(NW), Port Direction: Left Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -
Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 25, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9B solid-state auto switch, Number Of Switches
Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 25, Seal Type: Elastic Seal, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9B solid-state auto switch, Number
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SEAL, XLG-40-X1260, VACUUM SERIES, XLG NO SIZE RATING, .01034 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, O-RING, XLG-40-X1260, VACUUM SERIES, XLG NO SIZE RATING, .01034 lb
It was confirmed that XLG-80 satisfied it up to 2 million cycles, XLG-100 and XLG-160 satisfied it up to 1 million cycles. The test was performed with FKM, the standard sealant material.
Please contact us for the latest version.sales@ocaire.com, XLG NO SIZE RATING, VACUUM SERIES, XLG HIGH VACUUM VALVE, 2X, XLG NO SIZE RATING, 1.41611 lb