Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: Analog 4
Stations: 3 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate
Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: G, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate
Stations: 5 Stations, Piping: U Side: Open; D Side: Open, Thread Type: G, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate
Stations: 5 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate
Stations: 4 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: G, Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA
Stations: 3 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2:
Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Stations: 4 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Stations: 4 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: G, Flow Switch Type: Remote Sensor Unit, Rated Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Flow Switch
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2~16L/min), Return Unit: None, Thread: Rc, Port Size: 04 (1/2), Flow Switch Output: 2T (Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes)
Flow Switch Type: Remote Sensor Unit, Rated Flow Range: 2~16L/min, Return Unit: None, Thread: Rc, Port Size: 1/2, Flow Switch Output: Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Flow Switch Unit: -
Model: 2T (63mm Bore), Applicable Bore Size: 063 (63mm Bore)
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.