SMC Corporation of America
Elite Part Number Search
Search Results "VVEXB-1-10-01"

Please contact us for the latest version.sales@ocaire.com, MFLD ASSY, VALVE, VVX* MANIFOLD VX SERIES, NJ, VVX* BASE MT 1/8, 2.92112 lb

Please contact us for the latest version.sales@ocaire.com, MFLD ASSY, VALVE, VVX* MANIFOLD VX SERIES, PJ, VVX* BASE MT 1/4, 2.92112 lb

Description 0 1 0 1 VY110 0 1 VY120 0 1 VY130 0 1 0 1 0 1 VY140 VY170 0 1 VY190 0 1 VY1D00 VY150 VY1B0 VY1A0 ITV B F G N AN120-M5 VEXA-18-2A VEX1-18-1A VEX3-32A VEX5-32A VEX7-32A VEX9-32A Bracket (With bolt, washer) IC VEXA-18-3A VEX1-18-2A G27-10-01 AN120-M5 G36-10-01 AN101-01 AN120-M5 G46-10-01 AN210-02 G27-10-R1-X207 Pressure gauge ITVH Pilot EXH port silencer ITVX Sub-plate and Base Gasket

(Full span) 0.05 to 0.7 MPa Rc AF Mounting Linearity (3) AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Signal pressure (3) IR 1 8 Signal port PA (3) 02 03 02 04 04 06 10 10 12 14 20 01 Port P A R M5 01 M5 01 01 02 VEX Port size Rc (4) (4) 1 2 1 1 1 4 1 1 8 1

0 Model VY1D00-M5 10 M5 01 M5 Port M5 01 02 01 02 02 03 20 04 02 03 04 04 06 10 12 14 P Port size Rc 11 2 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 A M5 M5 M5 2 1 4 R 2 1 0.11 0.16 Weight (kg) (1) 0.19 0.25 0.35 0.55 0.75 1.5 2 4 Hysteresis (2) 1% F.S. 2.5% F .S. 3% F .S. 5% F .S.

02 03 04 0 1 VY150 04 06 10 0 1 VY170 0 1 10 12 01 02 0 1 0 1 01 02 0 1 VY190 0 1 14 20 M5 01 0 1 VY110 VY1D00-M5 VY1A0 -M5 VY1B0 VY120 VY130 Model 14 M5 01 04 02 03 04 20 10 M5 Port P A R mm2 M5 01 02 01 02 02 03 04 06 10 12 11 2 1 Port size M5 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 4 1 300 17 2 M5 M5 1 1 1 4 2 10 5 0.28 16 0.9 25 1.4 590 33 5 0.28 0.16 0.13 0.007 0.11 1%

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)

2% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)

Using the VVEXB/2/4 series, a maximum 10 station manifold is possible.Electro pneumatic regulator, Step-less control through electric signals, Simple circuit configuration, Internal or external pilot available, Base mounted or body ported styles, E/P REGULATOR, VALVE, VY1 E/P REGULATOR, MA, VY1 BASE MT .57320

/32), AN SILENCER $2.45 + Add to Quote Add To Cart Add to Cart SMC G27-10-01 gauge, AR REGULATOR $12.80 + Add to Quote

0.5% F.S.10 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressure? (Direct operated)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?