www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE E209 1.63 LINEAR ACTUATORS: AIR CYLINDERS SERIES CA1 D I M E N S I O N S T R U N N I O N M O U N T I N G B R A C K E T Applicable bore size (mm) Part No TA TL TU TC TX TE TO TR TT TS TH TF TY W1 Z TD-H10 40 80 60 10 102 85 119 17 9 17 12 45 60 62 10 93 15 +0.070 0 CA1-SO4 50 80 60 10 112 95
SV3000-50-1AFor single SV3000 SV3000-50-2AFor double C8: With 8 One-touch fitting N9: 5/16" One-touch fitting C10: With 10 One-touch fitting N11: 3/8" One-touch fitting C12: With 12 One-touch fitting 02: Rc 1/4 02N: NPT 1/4 03: Rc 3/8 03N: NPT 3/8 02F: G 1/4 02T: NPTF 1/4 03F: G 3/8 03T: NPTF 3/8 (Tie-rod for station additions and gaskets , , and are included.)
Note 1) Note 2) A, B port size (Metric) A, B port size (Inch) P, E port Applicable series P, E port Applicable series A, B port Symbol C3 C4 C6 C4 C6 C8 C6 C8 C10 C8 C10 C12 02 03 02F 03F M A, B port Symbol N1 N3 N7 N3 N7 N9 N7 N9 N11 N9 N11 02N 03N 02T 03T M 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 6 One-touch
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02B (Bottom, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02 (Side, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02 (Side, 1/4), Port Thread: Rc, SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 03 (Side, 3/8), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: Bottom, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: Side, 1/4, Port Thread: Rc, SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: Side, 3/8, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
N Note) Leave the box blank for the SI unit COM without input block (SD0).
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02B (Bottom, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: R (External Pilot)
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02 (Side, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: R (External Pilot)
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 03 (Side, 3/8), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: R (External Pilot)
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 03 (Side, 3/8), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: None, X Option: None, CE Compliant
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02B (Bottom, 1/4), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02 (Side, 1/4), Port Thread: Rc, SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: R (External Pilot)
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: Bottom, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: External Pilot, X Option: -, CE Compliant
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: Side, 1/4, Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: External Pilot, X Option: -, CE Compliant