There were no hits with the full part number, but there were 12 hits in the keyword search.
Product Information » New Products Search Results
or less 40 or less 30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
For 30 type, common external pilot (on manifold side).)
For 30 type, common external pilot (on manifold side).
ISG121-030 ISG221-030 Stainless steel 316 None 0.02 to 0.35 Cable gland ISA2 ISG121-031 ISG221-031 Stainless steel 316 Yes 0.02 to 0.45 Type A IS ISG130-030 ISG230-030 Brass, Phosphor bronze None 0.03 to 0.4 20a ISG130-031 ISG230-031 Brass, Phosphor bronze Yes 0.03 to 0.6 20b ZSM 0.1 to 1.0 1.5 0.02 ISG131-030 ISG231-030 Stainless steel 316 None 0.03 to 0.4 20c PF2 ISG131-031 ISG231-031
IDF37E-30 IDF55E-30 IDF75E-30 IDU22E-30 IDU37E-30 IDU55E-30 IDU75E-30 59 40 IDF15E1-20, IDF22E-20, IDF37E-20 IDU15E1-20 IDF22E-30, IDF37E-30 IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 30 mA 25 46 125 10 A 60 39 200 V type 60 81 148 50 36 73 133 IDF75E-30, IDU75E-30 IDF100F IDF125F IDF150F IDF190D IDF240D IDF370D 15 A 74 151 46 50 122 146 30 A 60 60 55 148 36 70 73 166 50 A IDF100F to 150F
Connection Female Thread: Rc, NPT, NPTF Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 60 3 to 5 1/4 30 to 60 8 to 12 3/8 15 to 45 14 to 16 1/2 15 to 30 20 to 22 Connection Female Thread: G Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 45 3 to 4 1/4 15 to 30 4 to 5 3/8 15 to 30 8 to
Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: (1) 8 A or less (including shorts), and (2) When controlled by a circuit protector (fuse, etc.) with the following rating Max. current rating No-load voltage (V peak) 5.0 0 to 20 [V] 100 Over 20 [V] to 30 [V] Peak voltage value 2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
5 50 l 31.3 14.9 30 5 34 50 48 l 5 1 2 1 2 5 4 3 4 3 Socket connector pin arrangement Socket connector pin arrangement Terminal no.
ISG121-030 ISG221-030 Stainless steel 316 None 0.02 to 0.35 Cable gland ISA2 ISG121-031 ISG221-031 Stainless steel 316 Yes 0.02 to 0.45 Type A IS ISG130-030 ISG230-030 Brass, Phosphor bronze None 0.03 to 0.4 20a ISG130-031 ISG230-031 Brass, Phosphor bronze Yes 0.03 to 0.6 20b ZSM 0.1 to 1.0 1.5 0.02 ISG131-030 ISG231-030 Stainless steel 316 None 0.03 to 0.4 20c PF2 ISG131-031 ISG231-031
2.3 2.3 3-6.3 3-6.3 ZSP 23 20 26 23 20 26 30 29 10 30 29 10 ISA2 77 77 99 99 IS 126 126 R 3/8 R 3/8 ZSM PF2 IF Dripproof type ISG210 to 291-030 (Without hysteresis scale plate) ISG210 to 231-031 (With hysteresis scale plate) Data Hysteresis adjusting bolt Hysteresis adjusting bolt Setting pressure adjusting bolt Setting pressure adjusting bolt 75 18 8.5 110 56 175 110 56 175 93 8.5 30 2.3
50% 70% 10% 30% 50% SY 150 300 Stroke (mm) 70% Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke
Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: (1) 8 A or less (including shorts), and (2) When controlled by a circuit protector (fuse, etc.) with the following rating Max. current rating 5.0 100 Peak voltage value No-load voltage (V peak) 0 to 20 [V] Over 20 [V] to 30 [V] 2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
Applicable manifold model DXT154-34-1A VV5F1-31 AN120-M5 VV5F1-31 AN110-01 VV5F1-30 DXT144-13-2A VV5F1-30/31 Description Throttle valve VV5F1-30 VFS Silencer VS4 Blanking plate assembly VQ7 How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Example) VV5F1-30-051 1 pc.
(Example) VV5Z3-40-031-M5 1 pc. (Manifold base) VZ3140-5G-M52 pcs. (Valve) DXT192-13-1A1 pc. (Blanking plate assembly) VV5Z3-43-031-C41 pc. (Manifold base) VZ3140-5LZ1 pc. (Valve) VZ3240-5LZ1 pc. (Valve) DXT192-13-1A1 pc. (Blanking plate assembly) EVS VFN The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
30 25 5, 10, 15, 20, 25, 30, 40 60 32 5, 10, 15, 20, 25, 30, 40 60 40 5, 10, 15, 20, 25, 30, 40 60 Courtesy of Steven Engineering, Inc. !
V100-31-1A V100-74-1 Material FKM, Steel Aluminum die-casted Number 10 11 Note Gasket, 2 screws Gasket assembly Sub-plate VFN R A P 2 4 8 6 11 10 1 How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A SY100 30 A Lead wire length Without lead wire: (With connector and 2 sockets) Nil 6 10 15 20 25 30 50
No.EX-OMN0029CN-D TMSI DeviceNet // EX600-SDN#A EX600-ED# 3 9 10 12 12 15 15 17 SI 18 18 19 19 20 LED 25 27 27 28 29 29 30 30 31 31 31 -1No.EX-OMN0029CN-D 33 34 43 43 54 EDS 54 TM 55 RSNetWorx for DeviceNet 59 60 63 TM 65 DeviceNet 77 -2No.EX-OMN0029CN-D *1) (ISO/IEC)(JIS) *2) *1) ISO 4414 Pneumatic fluid power -General rules relating to systems ISO 4413