SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS2-01CD1-053-02"

Base Mounted Wiring: 01CD (Base Mounted Plug-in w/Multi-connector on D Side), Pilot Type: Internal Pilot or None, Junction Cover: 1 (One-piece Junction Cover), Stations: 5 Stations, Passage: 3 (P: Common, EA,EB: Individual, Port A,B: Side), Port Size: 02 (1/4), Thread: F (G)

Base Mounted Wiring: Base Mounted Plug-in w/Multi-connector on D Side, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 5 Stations, Passage: P: Common, EA,EB: Individual, Port A,B: Side, Port Size: 1/4, Thread: G, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Part Number Description: VV*FS* BASE MT 1/4    Product Line: V   Product Line Description: VALVE    Family Code: 351   Family Description: VV*FS* MANIFOLD VFS SERIES    Class Code: PN    Click here to report information errorImage shown may not match exact part number

02 Pressure center VFS2510-E-01 02 DIN terminal: Double VFS2210-D Y-01 02 Closed center VFS2310-D Y-01 02 Exhaust center VFS2410-D Y-01 02 Pressure center VFS2510-D Y-01 02 EVS VFN With light/surge voltage suppressor Lead wire O.D.

(Manifold base) (2 position single) (2 position double) (Blanking plate) VV5FS2-20-061-03 VFS2120-1D-02 VFS2220-1D-02 VVFS2000-10A-1 1 3 2 1 The asterisk denotes the symbol for assembly.

02 Pressure center VFS2510-E-01 02 DIN terminal: Double VFS2210-D Y-01 02 Closed center VFS2310-D Y-01 02 Exhaust center VFS2410-D Y-01 02 Pressure center VFS2510-D Y-01 02 EVS VFN With light/surge voltage suppressor Lead wire O.D.

SERIES 15 FLOW CHARTS 400 400 1/32 1/32 3/64 3/64 1/16 1/16 3/32 3/32 1/8 1/8 ORIFICE-INCH ORIFICE-INCH 100 100 50 50 PRESSURE PRESSURE DROP ROP PSI PSI 10 10 5 01 01 02 02 05 05 1 2 5 WATER FLOW-GPM SERIES 50 FLOW CHARTS COAST PNEUMATICS 8055 E.

PSI PSI 10 10 5 01 01 02 02 05 05 1 2 5 WATER FLOW-GPM SERIES 58 FLOW CHARTS 97 SOLENOID VALVES . . .

VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil no. PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C Coil assembly with terminal part no.

For the driver of 200 W to750 W, the built-in regenerative resistor is used. 02: LEC-MR-RB-032 03: LEC-MR-RB-12 _ x _ _ For manufacturer setting 0h x _ _ _ 0h 5 13 5. PARAMETERS Control Initial value No.

For driver of 200W to 400W, regenerative resistor is not used. 02:LEC-MR-RB-032 03:LEC-MR-RB-12 13 10 13. OPTIONS AND AUXILIARY EQUIPMENT (3) Connection of the regenerative option POINT For the sizes of wires used for wiring, refer to section 13.4. The regenerative option will cause a temperature rise of 100 relative to the ambient temperature.

(a) 200V class servo motor 50 Dynamic brake time 40 constant [ms] 30 73 43 T9 T8 20 23 T7 10 13 053 T5 T6 0 0 1000 2000 3000 4000 5000 6000 Speed [r/min] LE-T12.3.2 The dynamic brake at the load inertia moment Use the dynamic brake under the load inertia moment ratio indicated in the following table.

DIN terminal Closed center: VFR2310Exhaust center: VFR2410Pressure center: VFR2510L plug connector Closed center: VFR2310-LExhaust center: VFR2410-LPressure center: VFR2510-LM plug connector Closed center: VFR2310-MExhaust center: VFR2410-MPressure center: VFR2510-M01 02 01 02 01 02 01 02 01 02 01 02 01 02 D Y 01 02 D Y 01 02 D Y Applicable cable O.D. 6 to 8 [4.5 to 7] Light/Surge voltage

L plug connector Closed center: VFR2310-LExhaust center: VFR2410-LPressure center: VFR2510-LM plug connector Closed center: VFR2310-MExhaust center: VFR2410-MPressure center: VFR2510-MDIN terminal Closed center: VFR2310Exhaust center: VFR2410Pressure center: VFR251001 02 01 02 01 02 01 02 01 02 01 02 01 02 D Y 01 02 D Y 01 02 D Y Applicable cable O.D. 6 to 8 [4.5 to 7] Light/Surge voltage

For driver of 200 to 7kW, built-in regenerative resistor is used. 02: LEC-MR-RB-032 03: LEC-MR-RB-12 12 10 12. OPTIONS AND AUXILIARY EQUIPMENT (4) Connection of the regenerative option POINT For the sizes of wires used for wiring, refer to section 12.6. The regenerative option will cause a temperature rise of 100 relative to the ambient temperature.

VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil assembly with terminal part no. Coil no.

Applicable manifold base model VP300-25-1A VV3P3 Blanking plate assembly (With a gasket and two mounting bolts) VP500-25-1A VV3P5 VP700-25-1A VV3P7 VV3P3-41-051-02 VV3P5-42-053-03 How to Order Manifold Assembly (Example) Ordering example (VV3P3-41) VP344-5GZ1-B VP344-5GZ1-A VP300-25-1A Stations 3 2 1 D side U side VV3P3-41-051-02 1 set (Type 41, 5-station manifold base part no.)

VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil no. PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C Coil assembly with terminal part no.