Applicable manifold model DXT155-17-1A VV5F3-30/40 DXT031-38-1A VV5F3-30/40/50 Note) VV5F3-71 Note) Used to exhaust air individually from certain valves mounted on common exhaust manifolds Type 30 and Type 40. How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.
VR VH Body ported single solenoid Foot bracket VFA3122 F 02 VHS Body ported For 30 type manifold VFA3 1 0 3 02 Base mounted For 40 type manifold VFA3 1 0 4 02 Port size For 50 type manifold VFA3 1 50 W/o sub-plate (Pilot port: Rc) Nil W/o sub-plate (Pilot port: Other than Rc) Thread type for pilot port 00 For 60, 61,70, 71 manifold VFA3 1 0 6 02 02 03 1 4 3 8 Nil 00F 00N 00T Rc G NPT NPTF
V100-31-1A V100-74-1 Material FKM, Steel Aluminum die-casted Number 10 11 Note Gasket, 2 screws Gasket assembly Sub-plate VFN R A P 2 4 8 6 11 10 1 How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A SY100 30 A Lead wire length Without lead wire: (With connector and 2 sockets) Nil 6 10 15 20 25 30 50
Body ported single solenoid VFA3122 F 02 Foot bracket Body ported For 30 type manifold VFA3 1 0 3 02 Base mounted For 40 type manifold VFA3 1 0 4 02 Port size W/o sub-plate (Pilot port: Rc) VFA3 1 5 0 For 50 type manifold Nil Thread type for pilot port W/o sub-plate (Pilot port: Other than Rc) 00 For 60, 61,70, 71 manifold VFA3 1 0 6 02 02 03 1 4 3 8 Nil Rc G NPT NPTF 00F 00N 00T Function
VR VH Body ported single solenoid Foot bracket VFA3122 F 02 VHS Body ported For 30 type manifold VFA3 1 0 3 02 Base mounted For 40 type manifold VFA3 1 0 4 02 Port size For 50 type manifold VFA3 1 50 W/o sub-plate (Pilot port: Rc) Nil W/o sub-plate (Pilot port: Other than Rc) Thread type for pilot port 00 For 60, 61,70, 71 manifold VFA3 1 0 6 02 02 03 1 4 3 8 Nil 00F 00N 00T Rc G NPT NPTF
How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover For other voltages of AC: SY100 30 3A Groove DC polar indication Lever Pin Without lead wire: SY100 30 A Lead wire length -+ Socket (with connector and 2 of sockets only) Lead wire Connector Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000
How to Order Connector Assembly 30 4A SY100 For DC: 30 1A SY100 For 100 VAC: 30 2A SY100 For 200 VAC: 30 3A SY100 For other voltages of AC: Caution When making connections, please note that using other than the specified size (3.5 to 7) cabtire cable will not satisfy IP65 (enclosure) standards.
4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).
For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover For other voltages of AC: SY100 30 3A Groove DC polarity display Lever Pin Without lead wire: SY100 30 A Lead wire length -+ Socket (with connector and 2 of sockets only) Lead wire Nil 6 10 15 20 25 30 50 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm (For DC) 10-SYJ3123-5LO-M3 SY100-30-4A-20 Connector How to
M8 connector 1-5-53 54 Series SYJ7000 How to Order Connector Assembly for L/M Plug Connector How to Order M8 Connector Cable : SY100-30-4AFor DC V100-49-1: SY100-30-1AFor 100 VAC : SY100-30-2ACable length For 200 VAC 300 mm 1 : SY100-30-3AFor other voltages of AC 500 mm 2 1000 mm 3 2000 mm : SY100-30-A 4 Without lead wire 5000 mm 7 (with connector and 2 of sockets only) Lead wire length Nil
SY7000221-1A [for 10 valves (30 pcs.)] SY7000222-1A [for 10 valves (30 pcs.)]
Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)
Lead wire color 30 4A SY100 For DC: Red, Black 3. Loosen the terminal screws (slotted screws) on the terminal block, insert the cores of the lead wires into the terminals according to the connection method, and fasten them securely with the terminal screws. 30 1A SY100 For 100 VAC: Blue 30 2A SY100 For 200 VAC: Red 30 3A SY100 4. Secure the cord by fastening the ground nut.
M8 connector 50 Series SYJ7000 How to Order Connector Assembly for L and M Plug Connector How to Order M8 Connector Cable : SY100-30-4AFor DC V100-49-1: SY100-30-1AFor 100 VAC : SY100-30-2ACable length For 200 VAC 300 mm 1 : SY100-30-3AFor other voltages of AC 500 mm 2 1000 mm 3 2000 mm : SY100-30-A 4 Without lead wire 5000 mm 7 (with connector and 2 of sockets only) Lead wire length Nil
Cylinder bore size/Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches /Refer to page 5.3-2 of "Best Pneumatics No. 2" for auto switch related information.
30 25 5, 10, 15, 20, 25, 30, 40 60 32 5, 10, 15, 20, 25, 30, 40 60 40 5, 10, 15, 20, 25, 30, 40 60 Courtesy of Steven Engineering, Inc. !
35 43 49 61.5 74 4.2-40 VND 32A, 40A, 50A Port size Model Main port Rc(PT) Pilot port Rc(PT) A B C D E F G H J 1 8 1 4 1 4 105 120 140 77 96 113 53 60 74 26.5 30 37 121.5 138 161 20 24 24 130.5 148 171 8 10 12 55 63 74 1 4 1 2 1 1 2 VND50D-32A VND60D-40A VND70D-50A Flange/32F, 40F, 50F Port size VX VN VQ Model Pilot port Rc(PT) Applicable flange A B C D E F G H J 8 10 12 50 40 32 1 8 1 4