Series: VP700, Exhaust Type: Common Exhaust, Pilot Type: Internal Pilot, Stations: 4 Stations, Symbol: 1, Port Size: 1/2, Thread Type: NPTF

Series: VP700, Exhaust Type: Common Exhaust, Pilot Type: Internal Pilot, Stations: 4 Stations, Symbol: 1, Port Size: 1/2, Thread Type: NPT

SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit).  The VP series may be used as either a selector valve, or a divider valve.  It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa. 3 PORT SOLENOID VALVE. VP valve manifold. 2020.00000

SMC's?VP300/500/700 series solenoid valve, offers high flow capacity and?reduced power consumption (1.55W standard, 0.55W with power saving circuit).? The VP series may be?used as either a?selector valve, or a divider valve.? It?is?available in a normally closed?or a normally open style. The series is vacuum applicable up to ?101.2kPa., MANIFOLD BASE, VALVE, VP3/5/7 SOL VALVE 3-PORT,

SMC's?VP300/500/700 series solenoid valve, offers high flow capacity and?reduced power consumption (1.55W standard, 0.55W with power saving circuit).? The VP series may be?used as either a?selector valve, or a divider valve.? It?is?available in a normally closed?or a normally open style. The series is vacuum applicable up to ?101.2kPa., MANIFOLD BLOCK, VALVE, VP3/5/7 SOL VALVE 3-PORT,

Common exhaust: VV3P7-41Stations 1-04 (G) (E) (T) (D, Y) N.C.

3 8 1 2 VV3P3 VV3P5 VV3P7 Base type 42 41 Individual exhaust Common exhaust VV3P3-41-051-02 Symbol Supply port is common.

When either 0002H or 0003H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to a number between -3 and 0. 5. When 0004H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to 0. 8-130 8 MECHATROLINK-III Commands Parameter Name Setting Units Factory Enabled Size Category No.

An encoder output pulse setting error (A.041) will occur if the setting is outside the allowable range or does not satisfy the setting conditions. Pn212 = 25000 (P/Rev) is accepted, but Pn212 = 25001 (P/Rev) is not accepted. The alarm A.041 is output because the setting unit differs from that in the above table. 2. The upper limit of the pulse frequency is approx. 1.6 Mpps.

SYJ SZ Body type Plug-in type VVFS5000-R-04-1 Non plug-in type VVFS5000-R-04-2 Part no. VP4 For details, refer to page 1308.

How to Order Sub-plate Assembly Pilot type Nil R External pilot Internal pilot Thread type Plug-in VFR4000 P 04 Nil Rc Non plug-in VFS4000 S 04 G F N NPT NPTF T B Plug-in VFR4000 P 04 Non plug-in VFS4000 S 04 B Piping port (P, A, B port) Note) Bottom ported is not available for external pilot.

PORTS . (2) PLACES 1.00 (25.4) .30 (7.5) Standard valve porting is NPT. .56 (14.3) .20 (5.2) .41 (10.3) .30 Nominal Power: (7.5) Mtg.

)-A Y610-(03)-A 04-A 02A VHS40-03A 04A VHS40-06A VHS50-06A 10A Pressure relief 3 port valve Note 6) VHS20-01A 02A VHS30-02A 03A Attachment 02-A E400-03-A 04-A 06-A Piping adapter Note 6) E100-M5-A 01-A E200-02-A 03-A 02-A E300-03-A 04-A E500-06-A E600-06 10 02-A IS10E-4003-A 04-A 06-A Pressure switch with piping adapter Note 6) 01-A IS10E-2002-A 03-A 02-A IS10E-3003-A 04-A Cross spacer

Model no. of switch rail accessory is listed on pages 8-15-32 and 8-15-41.

AM150C-02 2.2 18 10.6 AMH250C-03 AMD250C-03 AME250C-03 AMF250C-03 AT6C-04 IDFB4E HAA7-06 AFF4C-03 HAW7-06 AM250C-03 3.7 30 17.7 AMH250C-03 AMD250C-03 AME250C-03 AMF250C-03 AT6C-04 IDFB6E HAA7-06 AFF4C-04 HAW7-06 AM250C-03 5.5 42 24.7 AMH350C-04 AMD350C-04 AME350C-04 AMF350C-04 AT11C-06 IDFB8E HAA15-10 AFF8C-04 HAW22-14 AM350C-04 7.5 60 35.3 AMH350C-04 AMD350C-04 AME350C-04 AMF350C-04 AT11C

41 02 3 VV3PA Thread type SA Nil Rc G NPT NPTF VP Air operated manifold F VA N T SA Body size A port size VV3PA7-41-051-04 3 5 standard 1 4 Symbol Port size Rc 02 03 04 Applicable manifold base model VA 3 8 standard standard 7 1 2 1 4 3 8 1 2 VV3PA3 VV3PA5 VV3PA7 VM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local

8 -04 R 1/2 -04 R 1/2 Straight Union KGH KGLU12-02 R 1/4 12 -03 R 3/8 -04 R 1/2 Applicable tubing O.D.

41 02 3 VV3PA Thread type SA Nil Rc G NPT NPTF VP Air operated manifold F VA N T SA Body size A port size VV3PA7-41-051-04 3 5 standard 1 4 Symbol Port size Rc 02 03 04 Applicable manifold base model VA 3 8 standard standard 7 1 2 1 4 3 8 1 2 VV3PA3 VV3PA5 VV3PA7 VM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local

IDF1E to 75E IDU3E to 75E p. 40, 41 Foundation bolt set For fixing the air dryer to the foundations. Easy to secure by striking the axle. Stainless steel IDF4E to 75E IDU3E to 75E IDF100F to 150F p. 41 Piping adapter For converting the thread type of an IN/OUT fitting for air dryers.