VV317-02-051-02-A Valve stations A port size (Base piping) 1/4 Ordering example: VV317-02-051-02-A 1 pc. (5-station manifold base) VO317-1G 4 pcs. PVT317-53-1A 1 pc.
K E O F F TA K EO F F T Y P E 1 "T" Type 4 "X" Type T H R E A D T Y P E Nil Rc(PT) N NPT P O R T S I Z E M5 M5 x 0.8 01 1/8 02 1/4 03 3/8 04 1/2 mm mm Model Port Size A B C Model Port Size A B C D Y11-M5 M5X0.8 8 12 8 Y14-M5 M5 23 16 14 25 Y21-01 1/8 10 29 19 Y24-01 1/8 40 40 22 40 Y21-02 1/4 10 29 19 Y24-02 1/4 40 40 22 40 Y31-01 1/8 11 33 19 Y34-02 1/8 49 43 28 48 Y31-02 1/4 11 33 19 Y44
Stations: 15 Stations, Piping: P Common, R Common, A Side, Thread: NPTF, Option: -, CE/UKCA Compliant: -
Stations: 15 Stations, Piping: 1 (P Common, R Common, A Side), Thread: T (NPTF)
(R) (70) 20 16 19 11 * 0.5 MPa supply 31.5 1/4 1(P) F.O.F.* 65 N T.T. 1.2 343 2/3 Port Mechanical Valve Series VM200 Directional Control Valves Series VM200 With bracket VM220-02-A-B VM230-02-A-B With bottom mounting thread VM220U-02-A VM230U-02-A SY EX600 M5 x 35 Bracket mounting bolt (12.5) VM 2 x 5.4 mounting hole For mounting bolt, a hexagon socket head cap screw is recommended.
127 236 Base Mounted Manifold Series SY9000 43SA Type C8, N9 C10, N11 C12 02 03 SY9000: SS5Y9-43SA Stations B , (-D) One-touch fitting [1(P), 3/5(R) port] Applicable tubing O.D.: 12, 3/8" With External Pilot Specifications (Pitch) 22.3 24.3 22.2 P=24 R R 4 A 4 A 4 A 3/5 3/5 4 A 4 A R R 4 A 4 A 4 A 3/5 3/5 4 A 4 A 18 18.8 18.8 39.3 94.2 39.3 40.1 63.3 79.8 1 P 1 P 2 B 2 B 2 B 2 B 2 B SJ 1
03-A 02-A IS10E-3003-A 04-A Cross spacer Note 6) Y14-M5-A Y24-01-A 02-A Y34-01-A 02-A Y44-02-A 03-A Y54-03-A 04-A Note 1) in part numbers for a round pressure gauge indicates a pipe thread type.
4 3 position exhaust center 10-SY7000 02 02 03 1 4 S 5 VDC 5 3 position pressure center Note 1) : Enter a symbol for cable length.
D side Type 41P Type 42P SY9000-50-2A-C8 SY9000-50-2A-C10 SY9000-50-2A-C12 SY9000-50-2A-02 SY9000-50-2A-03 SY9000-18-2 SY9000-11-2 C8: A/B port 8 One-touch fitting C10: A/B port 10 One-touch fitting !2 Manifold block assembly 1 C12: A/B port 12 One-touch fitting How to install lead wire cover 02: A/B port Rc 1/4 Lead wire cover is only used for double solenoid valves.
This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
(mm) Auto switch model Bore size (mm) 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V) Auto switch model Bore size 20 25 32 40 D-A9l(V) 6 6 6 6 BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9l(V) D-M9lW(V) D-M9lA(V) 3 3 4 3.5 D-M9lA(V) Note 2) BM5-020S (A set of b, c, d, e) BM5-025S (A set of b, c, d, e) BM5-032S (A set of
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
Connector location on U side (FU) 3.5 163 10.7 47 106 71.7 9 9 U side 27 Manual override n X 12 12 2 B 4 A 8 2 B 4 A A A B A B A B A B A B A 7 SMC SMC SMC SMC SMC SMC SMC A A A A A A A B B B 2 B 4 A Indicator light 6 2 B 4 A 5 L2 L1 2 B 4 A 4 B B 2 B 4 A 3 2 B 4 A 2 P = 25 2 B 4 A 1 50.5 44 X Stations 38 27 Connector location on D side (FD) 11.7 16.2 139.9 (Single) 43.2 49.7 D side 148.9
pilot port) 44 62 9 9 91 44 62 Station number 50.5 59 2-Rc 1/8 (External pilot port) R4.5 R4.5 50.5 9 9 U side entry (LU) U side D side D side U side n 15 X X n X 12 12 12 12 8 B 2 A 4 B 2 A 4 8 Manual override 7 B 2 A 4 SMC SMC SMC SMC SMC SMC SMC B 2 A 4 7 A B A B A B A B A B A A A B A B A B A B A B A A SMC SMC SMC SMC SMC SMC SMC B B B A A A A A A A B A B 2 A 4 6 B 2 A 4 6 B B A A A A
Applicable pad 4020W/5020W/6020W/8020W Applicable pad 3507W/4010W/5010W/6010W Applicable pad 4030W/5030W/6030W/8030W A-A A-A A-A (5) (5) (5) 14.8 8.8 6 1.5 A A A A A A 2 0.8 2 3.5 4 4 15 15 30 3 5 5 3 5 3 0.8 0.8 8.4 12.8 20.4 Note) R part has to be smooth with no corners.
Applicable pad 4020W/5020W/6020W/8020W Applicable pad 3507W/4010W/5010W/6010W Applicable pad 4030W/5030W/6030W/8030W A-A A-A A-A (5) (5) (5) 14.8 8.8 6 1.5 A A A A A A 2 0.8 2 3.5 4 4 15 15 30 3 5 5 3 5 3 0.8 0.8 8.4 12.8 20.4 Note) R part has to be smooth with no corners.
Approx. 300 H: Approx. 600 (Lead wire length) 63 107.4[111.8] B A 27 A B Manual override R1 R2 P 8.5 34 2-4.3 (For mounting) 1/4, 1/8 (P, A, B port) (Light/surge voltage suppressor) 57.5[64.5] + 42.1 25.5 20 12 11.5 22 22 34 18 1/4 (R1, R2 port) 31.5 63 L plug connector (L): 10-SYJ7243-L01 02 M plug connector (M): 10-SYJ7243-M01 02 DIN Terminal (D): 10-SYJ7243-D01 02 M8 connector (WO): 10
A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
To connect a drain discharge pipe, use a pipe with a minimum bore of 10, and a maximum length of 5 m. Avoid using a riser pipe.
A, B, EA, EB port) Nil R External pilot Internal pilot 1 4 3 8 02 03