6 C6 10-SY5000 Power saving circuit is not available in the case of D, DO or W type.
-SYJ3000 (Single) and 10-SYJ7000, do not use it without bracket.
DO Without connector Note) Do not replace 10-V111 (G, H, L, M, W) with 10V115 (DIN terminal) and vice versa when replacing pilot valve assembly only.
-5 Gasket DXT192-10-5 (Use caution to the orientation.)
Manifold series 12 12 stations 10-SY3000-37-4A 3 10-SY3000 5 10-SY5000 Note) SS5Y3 has 4 to 12 stations. Manifold base (6 stations) 10-SS5Y3-20P-06 7 10-SY7000 1 2 3 Stations EA P EB Thread type Nil Rc G 00F 00N NPT 10-SS5Y3-20P-06 1 set (Type 20P, 6-station manifold part no.)
length) 64.3 [66.5] 54.5 [56.7] 63.4 56 49.5 R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 28 28 28 14 14 14 5 5 5 28.5 28.5 28.5 35.6 35.6 35.6 Refer to page 1-5-79 for dimentions with connector cable. 1-5-11 12 Series SYJ3000 2 Position Double [ ]: AC G H Grommet (G), (H): SYJ3240-M5 M5 x 0.8 (A, B port) 10 5 10 2-3.2 (For mounting) 22 2.5 Manual override B A 11 A B Courtesy of Steven Engineering
Type 20R Applicable solenoid valve SYJ312RSYJ322RHow to Order SS3YJ3 20R 05 A port M3 x 0.5 Applicable blanking plate assembly SYJ300-10-1A Stations P, R port thread type 02 2 stations Nil Rc : : X P R 00F R port G 20 20 stations 1/8 X port (External pilot type) M5 x 0.8 00N NPT P port 00T NPTF 1/8 Note) For more than 10 stations, supply/exhaust air to/from both sides of P port and R port
Air Fluid Operating pressure range (MPa) 0.15 to 0.7 Internal pilot Ambient and fluid temperature (C) Response time (ms) (at the pressure of 0.5 MPa) (1) 10 to 50 (No freezing. Refer to page 4-18-4.) 20 or less Max. operating frequency (Hz) 10 Flow characteristics Refer to the table below.
x 0.8 12 10 12 10 1 (P) 3 (R) 1 (P) XT34 Poppet VM200 2 port 3 port (A) 2 (A) 2 Side ported 1/4 Page 337 12 12 10 10 1 (P) 3 (R) 1 (P) VM400 3 port (OUT) 2 3 10 12 1 (N.C.)
(-Q) 10-SS3YJ3-42(-Q) 10-SS3YJ3-S42(-Q) Applicable base Sub-plate 10-SS3YJ3-41(-Q) 10-SS3YJ3-S41(-Q) 10-SS3YJ3-42(-Q) 10-SS3YJ3-S42(-Q) Applicable base 10-SS3YJ3-20(-Q) Manifold base Manifold base Manifold base Note) Add suffix -Q for the CE-compliant product.
Specifications Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50 (No freezing.
(Example) SS3YJ5-20-03 . 1 set (manifold base) SYJ512-5LZ-M5 . 2 sets (valve) SYJ500-10-1A . 1 set (blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (manifold base) SYJ514R-5G . 2 sets (valve) SYJ500-10-3A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
(Example) SS3YJ7-20-03 . 1 set (manifold base) SYJ712-5LZ-01 . 2 sets (valve) SYJ700-10-1A . 1 set (blanking plate assembly) SS3YJ7-42R-03-01 . 1 set (manifold base) SYJ714R-5G . 2 sets (valve) SYJ700-10-2A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
Specifications Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50 (No freezing.
Specifications Type of actuation Direct operated type 2 position single solenoid Fluid Air 5 to 50C (No freezing) Ambient and fluid temperature Response time (at 0.5 MPa) (1) 10 ms or less (Standard), 15 ms or less (Low power consumption type) Non-locking push type Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
For details, refer to the Best Pneumatics Vol. 3. 4-5-1 2 Series VK300 How to Order Electrical entry D: DIN terminal DO: DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) For the connector part number, refer to page 4-5-10.
Purchasing order is available in units of 10 pieces.
Class I, II, III Division 1 Groups A, B, C, D, E, F, G Class I Division 1 Groups A, B, C, D Hazardous Locations Warning Note) Do not install in Zone 0 (as defined in IEC 60079-10-1: 2008) or Zone 20 (as defined in IEC 60079-10-2: 2009) (Refer to page 40 for details) Note) Based on dynamic performance test, JIS B 8375-1981.
part number consists of 10 units.