SS5YJ3-S32-C4 Base mounted for internal pilot 10-SS5YJ3-41-M5 10-SS5YJ3-41-C4 10-SYJ343 1/8 10-SS5YJ3-S41-M5 10-SS5YJ3-S41-C4 10-SS5YJ3-46-M5 1/8 M5 x 0.8 10-SS5YJ3-46-C4 10-SYJ343 10-SS5YJ3-S46-M5 10-SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on
-S41-M5 Type 10-SS5YJ3-S41-C4 Type 10-SS5YJ3-46-M5 Type 10-SS5YJ3-46-C4 1/8 M5 x 0.8 10-SYJ343 Type 10-SS5YJ3-S46-M5 Type 10-SS5YJ3-S46-C4 Note) The values are for individually operated 2 position type manifold bases.
N,,13 x 0-5 0.05 tM3 x o.5l lo.o5l M3 x 0.5 0.04(18) NVJA322.M3 N.O. NVJA3l+M5 1G32 Nom. (M5) [10-32Nom. (M5) I IB3T ] 0.086(39) /without subplate\ \0.04(18) t NVJA324.M5 Bas mounted typo with subdato N.C. N.O. 0.1 t0.081 Note) B3T : One touch fitting for %' tube.
N,,13 x 0-5 0.05 tM3 x o.5l lo.o5l M3 x 0.5 0.04(18) NVJA322.M3 N.O. NVJA3l+M5 1G32 Nom. (M5) [10-32Nom. (M5) I IB3T ] 0.086(39) /without subplate\ \0.04(18) t NVJA324.M5 Bas mounted typo with subdato N.C. N.O. 0.1 t0.081 Note) B3T : One touch fitting for %' tube.
N,,13 x 0-5 0.05 tM3 x o.5l lo.o5l M3 x 0.5 0.04(18) NVJA322.M3 N.O. NVJA3l+M5 1G32 Nom. (M5) [10-32Nom. (M5) I IB3T ] 0.086(39) /without subplate\ \0.04(18) t NVJA324.M5 Bas mounted typo with subdato N.C. N.O. 0.1 t0.081 Note) B3T : One touch fitting for %' tube.
mounted for internal pilot SS5YJ3-41-C4 SYJ34 1/8 SS5YJ3-S41-M5 SS5YJ3-S41-C4 SS5YJ3-46-M5 SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 SS5YJ3-S46-M5 SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.
0.079 0.084 0.081 0.084 0.024 0.047 0.024 0.024 SS5YJ3-32-C4 SYJ33 1/8 SS5YJ3-S32-M5 SS5YJ3-S32-C4 SS5YJ3-41-M5 Base mounted for internal pilot SS5YJ3-41-C4 SYJ34 1/8 SS5YJ3-S41-M5 SS5YJ3-S41-C4 SS5YJ3-46-M5 SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 SS5YJ3-S46-M5 SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the
13 13 5 5 10 10 5-M5 X 0.8 10 10 5-M5 X 0.8 28 (Piping port) 28 (Piping port) [ ] for AC Other dimensions are the same as the grommet style. [ ] for AC Other dimensions are the same as the grommet style. 1.2-16 Series SYJ3000 3 Position Closed Center/Exhaust Center/Pressure Center 3 4 5 G H Grommet (G), (H): SYJ3 40-l ll-M5 10 9 5 10 SY 16.5 33.5 SYJ 2-1.8 (Mounting holes) Manual override
x 0.5 SS3Y1-31 M5 x 0.8 M3 x 0.5 SS3Y1-S41 M5 x 0.8 M5 x 0.8 Note) Value at manifold base mounted How to Order Valve Manifold Assembly Example Stations3 2 1 Valve (N.C.)
-C4 Type SS5YJ3-41-M5 Base mounted for internal pilot Type SS5YJ3-41-C4 SYJ34 1/8 Type SS5YJ3-S41-M5 Type SS5YJ3-S41-C4 Type SS5YJ3-46-M5 Type SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 Type SS5YJ3-S46-M5 Type SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the
-32-C4 SYJ33 1/8 SS5YJ3-S32-M5 SS5YJ3-S32-C4 SS5YJ3-41-M5 Base mounted for internal pilot SS5YJ3-41-C4 SYJ34 1/8 SS5YJ3-S41-M5 SS5YJ3-S41-C4 SS5YJ3-46-M5 SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 SS5YJ3-S46-M5 SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on
with connector cable. 608 Series 10-SYJ300 Manifold Specifications [Option] Manifold Specifications For internal pilot Type 20 Type 41, S41 Type 42, S42 Model Manifold type Single base/B mount P (SUP), R (EXH) Common SUP/Common EXH Valve stations 2 to 20 stations Location Valve Base A port Porting specifications Direction Top Side M5 x 0.8 M5 x 0.8 1/8 P, R port Port size M5 x 0.8 C4 (4
Applicable blank plate assembly SY100-77-1A P R 20 stations VP 20 R port M5 X 0.8 P port M5 X 0.8 VG VP Note 1) SY113 (A) and SY123 (A) cannot be mounted on the same manifold. S41 Type How to Order Applicable solenoid valve (1) SS3Y1 S41 05 M3 VQ SY114-l SY114A-l SY124-l SY124A-l Stations A port size M3 M5 M3 X 0.5 M5 X 0.8 VQZ 2 stations 02 ... ...
S41 Type/Side Ported [ ] for AC VS SS3YJ3-S41Station -M3 L plug connector (L) M plug connector (M) 48.6(GZ, GS: 49.3) [50.3] 41.5 [48] P R P R 11 22 28 29.1 2-3.5 (Lead wire length) (Mounting holes) 300 52.6 [59.1] 300 (Lead wire length) 41.5 [48] L2 4-M5 X 0.8 L1 48.9 [50.2] (P, R port) 58.5 44.9 41.5 [48] 13 4.5 13 4.5 29.1 22.5 A A 13 10 5 5 4-M5 X 0.8 P=10.5 13.5 (P, R port) n-M3 X 0.5
+ M5 x 0.8 (X port) VP 35.6 28.5 26.1 X R P S070 13 5 5 10 M5 x 0.8 (P, R port) 10 8.6 7.5 VQ 17.5 23 VKF VQZ L plug connector (L): SYJ34-L-M5 M plug connector (M): SYJ34-M-M5 M8 connector (WO): SYJ34-WO-M5 VZ VS VFN Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.5 [60.7] 48.7 [50.9] 57.6 50.2 43.7 R P R P R P 10 8.6 10 8.6 10
S 20 20 stations A,B port size R Port M5 0.8 M5T M5 0.8 A, B Port M5 0.8 A, B Port M5 0.8,N3T P Port M5 0.8 P Port NPTF N3T One-touch fitting Type 41(5 Port / Base mounted type) Applicable solenoid valve: SYJ3 40SYJ3 43SS5YJ341-05 --N3T Type 41 Type S41 Single solenoid coil is located on same side as the A, B port. ( ) Applicable blank plate ass'y: SYJ3000-21-2A Valve mounting direction
: SYJA34-M5 14 5 10 Manual override (Non-locking) 2-3.2 (External pilot port) (For mounting) 17 3 (For solenoid valve) 2.5 M3 x 0.5 (Pilot port) A 11 17.5 1.5 21 27 30 28.5 P R 1 (Breathing hole) 13 5 8.6 10 (P , A, R port) M5 x 0.8 23 5-4-5 3 Port Air Operated Valve Series SYJA500/700 How to Order Port size M5 x 0.8 M5 Symbol Bore size Applicable series SYJA500 SYJA700 01 1/8 Bracket With
M5 x 0.8 (A port) 14 5 10 2-3.2 (For mounting) 26.4 17 3 2.5 Manual override A 11 G: Approx. 300 H: Approx. 600 (Lead wire length) 48.6 [50.8] (Light/surge voltage suppressor) 41.5 [48.5] + M5 x 0.8 (X port) 35.6 28.5 26.1 X R P 13 5 5 10 M5 x 0.8 (P, R port) 10 8.6 7.5 17.5 23 L plug connector (L): SYJ34-L-M5 M plug connector (M): SYJ34-M-M5 M8 connector (W0): SYJ34-W0-M5 Approx. 300 (Lead
4" one-touch fitting) M5 0.8 1/8 NPTF Port size M5 0.8 A port X port Note1) M5 0.8 M5 0.8 M5 0.8 Body ported type SYJ5 2/SYJ5 2R 3.4 (0.19) Note 2) Valve effective area mm2(Cv) M5 : 3.3 (0.18) 1/8 : 4.8 (0.27) N3T, N7T: 3.8 (0.21) Base mounted type SYJ5 4/SYJ5 4R M5 : 3.8 (0.21) 1/8 : 4.7 (0.26) Note 1 : Only for external pilot Note 2 : Value when used on a manifold Proper Combinations of
on same side of A and B port 1 station Nil P port: Rc 1/8 A port: M5 x 0.8 B port: M5 x 0.8 Thread type R port: Rc 1/8 20 Solenoid on same side of A and B port 20 stations Type S41 Nil F N T Rc S Type VK334 Type VK3140 Port size G M5 M5 x 0.8 C4 4 cassette NPT P port: Rc 1/8 NPTF R port: Rc 1/8 B port: M5 x 0.8 A port: M5 x 0.8 Type 42: Base mounted (A, B port side ported) How to Order Applicable