Station 9 SOL.B 22 SOL.A 10 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Station 10 SOL.B 23 SOL.A 11 Station 11 SOL.B 24 SOL.A 12 Station 12 SOL.B 25 Note) COM. 13 Positive COM spec. Negative COM spec. 1021-VV5Q21 The total number of stations is tabulated starting from station one on the D-side.
Station 9 SQ SOL.B SOL.A 23 10 Station 10 SOL.A VFS SOL.B 24 11 Station 11 SOL.B SOL.A 25 12 Station 12 VFR VV5Q21 COM. () Orange Red (+) 13 VQ7 Positive COM spec. Negative COM spec. The total number of stations is tabulated starting from station one on the D-side. Note) When using the negative common specifications, use valves for negative common. (Refer to page 419.)
(Initial value) Note 3) Value for high pressure type (1.5W) specification Note 4) Value for the low power consumption (0.5W) specification 56 Series VQ1000 VQ1000/Flat Cable Kit Stations VV5Q13J 0(D) U S Applicable connector: Flat cable connector (20P) (conforms to MIL-C-83503) L2 23.5 P = 11 13.2 L1 6.2 41 35 Indicator light 1.5 1.5 (11) 19.5 (Mounting hole dimension) Manual override 2-
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light & Surge Suppressor: E (None), Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 2 (200VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: E (None), Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 4 (220VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected