SMC Corporation of America
Elite Part Number Search
Search Results "VQ2200-21"

VVQ2000-10A-1 3 m Light/surge voltage suppressor VQ2200-51 VQ2200-51 VQ2200-51 0 1 VQ2200-51 VQ2100-51 VQ2100-51 VQ2100-51 Yes None Nil E Note) Type of actuation Note) Not applicable to the S kit.

Stations SYJ Seal Metal seal Rubber seal VVQ2000-10A-1 3 m VQ2200-51 Enclosure VQ2200-51 VQ2200-51 0 1 VQ2200-51 VQ2100-51 Nil SZ VQ2100-51 VQ2100-51 Dust-tight, Waterjet-proof (IP65) W Note) VF Type of actuation Note) T/L/S/M kit only.

seal 20 or less 26 or less Exhaust center 5.4 (0.3) VQ1401 Rubber seal 25 or less 33 or less 3.6 (0.2) VQ1500 Metal seal 20 or less 26 or less Pressure center 5.4 (0.3) VQ1501 Rubber seal 25 or less 33 or less Metal seal 22 or less 14.4 (0.8) 29 or less VQ2100 90 Single 2 position 3 position Rubber seal 24 or less 16.2 (0.9) 31 or less VQ2101 Metal seal 15 or less 14.4 (0.8) 20 or less VQ2200

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 4 (220VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: E (None), Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: E (None), Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: Dust Protected