Orifice and Port Size Combinations Class Orifice size (mm) T Conduit terminal (1) Port size 4 2 3 7 5 10 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 (8A) Available types of electrical entry are either G, C and T.
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
Valve Leakage Rate Fluid and Ambient Temperature Internal Leakage Seal material Leakage rate (Water) Note 1) Fluid temperature (C) Ambient temperature (C) VXD23 to 26 (8A to 25A) VXD27 to 29 (32A to 50A) 1 to 60 Note) 20 to 60 NBR (FKM) Note 2) 0.2 cm3/min or less 1 cm3/min or less Note) No freezing External Leakage Seal material Leakage rate (Water) Note 1) VXD23 to 26 (8A to 25A) VXD27
9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring is double wiring (connected to SOL. a and SOL. b) regardless of number
SX3000-64-8A M3 x 26 (Flat nickel plated) SX5000-57-5 6 SY3000-23-4 Round head combination screw 7 8 SX3000-57-4 VZ1000-11-1Gasket DIN rail Refer to page 98.
assembly 6 (NBR, FKM, EPDM) Stainless steel, Brass (C37) 32A to 50A (NBR, FKM, EPDM) Stainless steel Stainless steel 8A to 50A Valve spring 7 Stainless steel 8A to 50A Tube assembly 8 (NBR, FKM, EPDM) Stainless steel, PPS 8A to 50A Armature assembly 9 Stainless steel 8A to 50A Return spring 10 8A to 50A Solenoid coil 11 SK 8A to 50A Clip 12 The materials in parentheses are seal materials
(mm) 2 4 3 5 7 10 1/8 (6A) V V V V 2 1/4 (8A) V V V V 1/4 (8A) V V V V 3 3/8 (10A) V V V V V 1/2 (15A) V 1/4 ( 8A) V V V V Available types of electrical entry are either G, C and T.
VNA1A -6A, 8A, 10A VNA2 -10A, 15A VNA3 -20A VNA4 -25A VNA5 -32A VNA6 -40A VNA7 -50A No.
other than those listed above are the same as those for the standard type. 26 MXQA Series Dimensions: MXQ 8A [Functional Option] MXQ 8A-mm6 Centralized adjuster (8) *1 The extension stroke end adjuster (shock absorber) uses long adjustment nut and bolt specifications (-X28).
Piston assembly A VS8100-8A-1 VS8080-8A-1 VS8080-8A-3 VS8080-8A-1 VS8060-8A-2 VS8060-8A-4 VS8080-8A-1 VS8080-8A-1 VS8060-8A-1 1. Piston assembly A 2. Piston assembly B VS8080-8A-2 VS8080-8A-4 VS8060-8A-3 VS8080-8A-2 VS8080-8A-4 2. Piston assembly B 3. Gasket VS8080-17-1 VS8080-17-1 VS8080-17-1 VS8080-17-1 VS8060-17-1 VS8060-17-1 VS8080-17-1 VS8080-17-1 VS8060-17-1 3. Gasket 4.
SOL.A 1A () (+) 1B () (+) Station 1 SOL.B 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A () (+) 2B () (+) Station 2 SOL.B SOL.A 1.
SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 8B Station 8 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B SOL.A 9A 9B Station 9 SOL.B SOL.A 10A 10B Station 10 SOL.B COM COM. 668 Base Mounted Plug-in Unit VQC5000 Series T VQC5000 Kit (Terminal block box kit) IP67 compliant VV5QC51 SV L2 SYJ L1 10 88.7 (7.1) 59.5 P = 41 SZ Indicator light
D -DIN connector DL -DIN connector with light DO-For DIN connector (without connector) Orifice and port size combinations T -With conduit terminal TL-With conduit terminal/light Class Orifice diameter Port size 2 3 4 5 7 10 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) Connector 1/4 (8A) 3/8 (10A) 4 All class B coils are equipped with surge voltage suppressor.
) 1/4 ( 8A) VCS (for steam) 2 port solenoid valve 3/8 (10A) 3 PTFE (FKM) Brass (stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is available with seal meterial FKM only.
Detail name power reset (Note 2, 3) 86.1 Network communication error 1 SD Alarm 86 Network communication 86.2 Network communication error 2 SD error 86.3 Network communication error 3 SD USB communication USB communication time-out error/serial communication time-out error time-out error/ 8A.1 SD serial communication 8A time-out error/ Modbus RTU 8A.2 Modbus RTU communication time-out error
) 1/4 ( 8A) VCS (for steam) 2 port solenoid valve 3/8 (10A) 3 PTFE (FKM) Brass (stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is available with seal meterial FKM only.
D -DIN connector DL -DIN connector with light DO-For DIN connector (without connector) Orifice and port size combinations T -With conduit terminal TL-With conduit terminal/light Class Orifice diameter Port size 2 3 4 5 7 10 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) Connector 1/4 (8A) 3/8 (10A) 4 All class B coils are equipped with surge voltage suppressor.
Polarity 2 x G3/4 Electrical entry 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A Release valve 10B SOL.B 10A SOL.A 9B SOL.B 9A SOL.A 8B SOL.B 8A SOL.A 7B SOL.B 7A SOL.A 6B SOL.B 6A SOL.A 5B SOL.B 5A SOL.A 4B SOL.B 4A SOL.A 3B SOL.B 3A SOL.A 2B SOL.B 2A SOL.A 1B SOL.B 1A SOL.A () (+) 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 1A 1 station (+) () 1B SV Pressure switch
Polarity SOL.a (+) () 1A 1 station SOL.b (+) () 1B 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.a COM 10A 9A 8A 7A 6A 5A 4A 3A 2A 1A (+) () 2A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 2 stations SOL.b (+) () 2B SOL.a (+) () 3A 3 stations SOL.b (+) () 3B SOL.a 4A (+) () 4 stations SOL.b 4B (+) () SOL.a (+) () 5A 5 stations SOL.b 5B (+) () SOL.a 6A (+) () 6 stations SOL.b 6B
N.C. 0.12 0.03 0.35 0.03 0.72 1 M5 1/8 (6A) 0.04 0.13 0.96 VDW200 0.52 0.04 1 0.31 0.08 0.45 0.09 1.9 1.6 0.52 0.16 0.52 0.16 3.8 2 1.8 1/8 (6A) 1/4 (8A) VDW300 0.13 0.38 1.0 3.1 0.28 0.52 0.30 0.50 0.12 6.7 3 1.5 0.44 0.49 0.46 11 4 17-2-75 16 Series VDW200/300 Construction VDW250 VDW350 i o !0 i !1 o w !0 !