SMC Corporation of America
Elite Part Number Search
Search Results "VHK3A-M5-M5R"

Construction (2) VHK2A(R) VHK3A(R) (9) (4) (1) (5) (3) (11) (10) (7) (8) (6) No.

kPa 100.0 to 100 kPa Symbol Calibration certificate Nil K p Piping specifications Option 2 M5 female thread/Side ported Piping port None Nil M5 Panel mount adapter + Front protective cover M5 female thread/Rear ported D Note 3) M5R Piping port R1/8/Side ported 01 DIN rail adapter Note 5) R1/8 Piping adapter R Note 4) NPT1/8/Side ported N01 Note 3) Not available for piping specifications

Compound -100.0 to 100.0 kPa -100 kPa 100 kPa Positive pressure -0.100 to 1.000 MPa -0.1 MPa 0 1 MPa -57No.PS-OMM0005-J Dimensions Side piping Z/ISE10(F)-M5-#-# Rear piping Z/ISE10(F)-M5R-#-# -58No.PS-OMM0005-J Side piping Z/ISE10(F)-01-#-# Side piping Z/ISE10(F)-N01-#-# -59No.PS-OMM0005-J Panel mount side piping Z/ISE10(F)-M5-#-### + ZS-39-B Panel mount rear piping Z/ISE10(F)-M5R-#-###

adapter + Front protective cover M5 female thread/Rear ported D Note 3) M5R Piping port R1/8/Side ported 01 DIN rail adapter Note 5) R1/8 Piping adapter R Note 4) NPT1/8/Side ported N01 Note 3) Not available for piping specifications of 01 and N01.

① For the standard type, the part number is “VHK3A-10F-10F.”
② For the standard type, the part number is “VHK2A-02S-06F.” In July 2019, the VHK series was refreshed as the VHK-A series. The knob is now equipped with a function to prevent the knob from coming out, but the specifications and dimensions are the same as those of the existing product.

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover), Calibration Certification: K (w/Certificate

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover), Calibration Certification: K (w/Certificate

Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)