Except for M5 10-SS5Y3-41P-06-C6 1 set (Type 41P, 6-station manifold base part no.) SY3000-26-10A 1 set (Blanking plate assembly part no.) 10-SY3140-5LOU 3 sets (Single solenoid part no.) 10-SY3240-5LOU 2 sets (Double solenoid part no.) SY3000-37-3A 3 sets (Connector assembly part no.)
x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 10-SS5YJ3-32-M5 10-SS5YJ3-32-C4 10-SYJ333 1/8 10-SS5YJ3-S32-M5 10-SS5YJ3-S32-C4 Base mounted for internal pilot 10-SS5YJ3-41-M5 10-SS5YJ3-41-C4 10-SYJ343 1/8 10-SS5YJ3-S41-M5 10-SS5YJ3-S41-C4 10-SS5YJ3-46-M5 1/8 M5 x 0.8 10-SS5YJ3-46-C4 10-SYJ343 10-SS5YJ3-S46-M5 10-SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2
SY3140-5LOU . 2 sets (Single solenoid part no.) SY3240-5LOU . 2 sets (Double solenoid part no.)
Applicable series M5 Symbol Part no.
0.8 2 port M5 x 0.8 Note) V114(A) and V124(A) cannot be mounted to the same manifold.
0.8 2 port M5 x 0.8 Note) V114(A) and V124(A) cannot be mounted to the same manifold.
M5 x 0.8 Port 2 M5 x 0.8 Note) 10-V114(A) and 10-V124(A) cannot be mounted on the same manifold.
x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 10-SS5YJ3-32-M5 10-SS5YJ3-32-C4 10-SYJ333 1/8 10-SS5YJ3-S32-M5 10-SS5YJ3-S32-C4 Base mounted for internal pilot 10-SS5YJ3-41-M5 10-SS5YJ3-41-C4 10-SYJ343 1/8 10-SS5YJ3-S41-M5 10-SS5YJ3-S41-C4 10-SS5YJ3-46-M5 1/8 M5 x 0.8 10-SS5YJ3-46-C4 10-SYJ343 10-SS5YJ3-S46-M5 10-SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2
SS5YJ3-32-M5 0.25 0.25 0.25 0.24 0.32 0.32 0.33 0.32 0.20 0.21 0.20 0.22 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 0.19 0.18 0.26 0.21 0.25 0.28 0.29 0.27 0.25 0.27 0.25 0.34 0.060 0.059 0.060 0.057 0.081 0.079 0.082 0.079 0.048 0.050 0.048 0.057 0.32 0.30 0.29 0.27 0.33 0.35 0.34 0.34 0.10 0.21 0.19 0.10 0.25 0.27 0.15 0.18 0.19 0.24 0.17 0.24 0.12 0.13 0.16
X Port size) Sysytem Figure Silencer System Solenoid valve Speed controller 4 X M5 6 X M5 6 X 1/8 6 X M5 AS1301F-M5-04 A SYJ3000 M5 X 0.8 (S = 1.8mm2) AS1301F-M5-06 B q AN120-M5 (S=5mm2) AS2301F-01-06 C 6 X M5 AS2001F-06 D w 1.2-9 Series SYJ3000 How to Order Bracket Light and surge voltage suppressor Configuration S Z R U Without light and surge suppressor With surge suppressor With light
M4x16 Positioning pin 6x10 6 - MHM-25D-X7400A-HC10DT,HC10-(N/P) Hexagon socket head cap screwM6x23 Auto switch D-M9(N/P) Magnet gripper Adapter plate Exhaust throttle valve with silencer ASN2-M5-X937 Hexagon socket head cap screwM4x35 3-port solenoid valves V114-5LOU Positioning pins 4x8 Hexagon socket head cap screwsM4x12 ISO9409-1compliant flange M8-MolexConversion cable Hexagon socket
x 0.5 0.9 Type SS5YJ3-32-M5 0.25 0.25 0.25 0.24 0.32 0.32 0.33 0.32 0.20 0.21 0.20 0.22 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 0.19 0.18 0.26 0.21 0.25 0.28 0.29 0.27 0.25 0.27 0.25 0.34 0.060 0.059 0.060 0.057 0.081 0.079 0.082 0.079 0.048 0.050 0.048 0.057 0.32 0.30 0.29 0.27 0.33 0.35 0.34 0.34 0.10 0.21 0.19 0.10 0.25 0.27 0.15 0.18 0.19 0.24 0.17 0.24
-32-C4 SYJ33 1/8 SS5YJ3-S32-M5 SS5YJ3-S32-C4 SS5YJ3-41-M5 Base mounted for internal pilot SS5YJ3-41-C4 SYJ34 1/8 SS5YJ3-S41-M5 SS5YJ3-S41-C4 SS5YJ3-46-M5 SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 SS5YJ3-S46-M5 SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on
O.D.: 4, 5/32" : 6, 1/4" (2.3) L plug connector (L): SYJ5120-L-M5(-F) M plug connector (M): SYJ5120-M-M5(-F) DIN terminal (D): SYJ5120-D-M5(-F) M8 connector (W0): SYJ5120-W0-M5(-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 82.1 Max. 10 60.9 28.1 [35.1] 53.4 12.7 42.1 32.6 M8 x 1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 73 [75.2] (2.3) 63.2 [65.4] 83 72.1 3
(Recommended tightening torque: 0.4 to 0.5 Nm) 2) When piping fittings, etc. are connected to the air pressure supply (P) port (M5) for the single unit type, secure the part provided with the port, tighten it by hand, then additionally tighten by approximately one sixth to one fourth of a turn using an appropriate tool.
NPN1 + -100 to 100 FE PNP1 + 1) NPN1 + VA 1) PNP1 + VB 1 2) 2) M SI (kPa) 2) 3) (:psi) P 2) (99 10 ) 3) (1) VAVB (3) G 2m) W (2m) 4) (4) (5) (V ) 0 (M5x0.8) 5) K 1 3.2 () 4) 5) (1) VAVB 2 4 () 3 6 () 4 3.2 () 5 4 () 24 - No.ZQ-OM01401-B ZS-39-5G ZQ1-LW6-N-A 1) N NPN P PNP (1) 3 Assy ZQ1-PL11-A 4 Assy ZQ1-FC1-A 5 (10 ) ZQ1-FE2-A 6 ZQ1-CV 7 V VVQ1000-50A-C4 (1) 50A-M5
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)