SMC Corporation of America
Elite Part Number Search
Search Results "V114T-5HZ"

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0~0.7, Driving Type: Linear

Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 0.6m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted)

Customers looking for a compact, light-weight, high flow valve for piloting process valves or actuator applications, need search no longer.? SMC's?series V100?is one of the most advanced solenoid valves in today's market.??The standard V100 uses only 0.35w, which is 76% less than comparable valves.??The low power model uses only 0.1w, reflecting dramatic savings of up to 93% compared to

Customers looking for a compact, light-weight, high flow valve for piloting process valves or actuator applications, need search no longer.  SMC's series V100 is one of the most advanced solenoid valves in today's market.  The standard V100 uses only 0.35w, which is 76% less than comparable valves.  The low power model uses only 0.1w, reflecting dramatic savings of up to 93% compared to

Look up from the 5Hz switching cycle to find the intersection with SUP=0.35MPa. 2. From the point just found, draw a line to the Y-axis to find the air consumption. The result is approximately 9l/min (ANR). 1 0 2 3 4 5 6 7 8 9 10 Cycle (Hz) Caution 1. These flow rate characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.

Recommended Valve PA3000 PA5000 VQZ140 (exhaust center) VQZ240 (exhaust center) Refer to page 21 for further details. 6 Series PA3000/5000 Performance Curves/Air Operated Type PA513 Flow rate characteristics PA313 Flow rate characteristics 50 50 Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2, 0.3MPa) Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2MPa) SUP=0.5MPa 40 40 SUP=0.5MPa

Recommended Valve PA3000 PA5000 VQZ140 (exhaust center) VQZ240 (exhaust center) Refer to page 21 for further details. 6 Series PA3000/5000 Performance Curves/Air Operated Type PA513 Flow rate characteristics PA313 Flow rate characteristics 50 50 Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2, 0.3MPa) Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2MPa) SUP=0.5MPa 40 40 SUP=0.5MPa

H N I C A L SPECIFICATIONS S E R I E S VQZ100/200/300 Type Of Seal Metal Seal Rubber Seal Fluid Air, Inert Gas Air, Inert Gas Maximum Operating Pressure 0.7MPa / 102PSI (High Pressure Type 0.8MPa / 116PSI) Valve Specifications Solenoid Specifications Minimum Operating Pressure 0.1MPa / 14.5PSI 0.15MPa / 22PSI Ambient & Fluid Temperature -10 to 50C -10 to 50C Max Operating Frequency 20Hz 5Hz

H N I C A L SPECIFICATIONS S E R I E S VQZ100/200/300 Type Of Seal Metal Seal Rubber Seal Fluid Air, Inert Gas Air, Inert Gas Maximum Operating Pressure 0.7MPa / 102PSI (High Pressure Type 0.8MPa / 116PSI) Valve Specifications Solenoid Specifications Minimum Operating Pressure 0.1MPa / 14.5PSI 0.15MPa / 22PSI Ambient & Fluid Temperature -10 to 50C -10 to 50C Max Operating Frequency 20Hz 5Hz

Clean room Assembled and double-packaged in clean-room environment Note) With 3/8" inlet/outlet tube: 1 to 12l * The values appearing in the above table are representative of use in a room temperature environment and with tap water. 3 Series PA3000 Performance Automatically operated type Air pilot actuation type * Solenoid valve switching cycle PA3313-m03: Flow rate characteristics (5Hz

Internal pilot: 1 to 5HZ and external pilot: 1 to 8Hz is reference. The charts on page 10 show the relation for the adjustment needle value and operation frequency. However, there is approx. 2Hz of variation depending on individuality. Operating conditions affect the operating frequency.

Standard Specifications Standard Specifications Type of seal Metal seal Rubber seal Fluid Air, Inert gas Air, Inert gas Max. operating pressure 100 psi (0.7MPa) High pressure type 113 psi (0.8MPa) Min. operating pressure 14 psi (0.1MPa) 21 psi (0.15MPa) Valve specifications Solenoid specifications Note 1) Note 1) Ambient and fluid temperature 14 to 122F 14 to 122F Max. operating frequency 20Hz 5Hz

Fluid Air Operating pressure range 0.2 to 0.5MPa Internal pilot type Ambient and fluid temperature 5 to 50C Response time (for 0.5MPa) Note 1) 25ms or less Maximum operating frequency 5Hz Manual operation Non-locking push type, Push-turn slotted locking type Pilot valve individual exhaust type, Main valve/pilot valve common exhaust With vacuum pressure gauge Pilot exhaust type Lubrication

Fluid Air Operating pressure range Internal pilot type 0.2 to 0.5MPa (29 to 72 psi) 5 to 50C (41 to 122F) Ambient and fluid temperature Response time (for 0.5MPa) Note 1) 25ms or less Maximum operating frequency 5Hz Manual operation Non-locking push type, Slotted locking type With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust

Type of valve actuation Air Fluid 0.2 to 0.5MPa Operating pressure range Internal pilot type 5 to 50C Ambient and fluid temperature 25ms or less Response time (for 0.5MPa) Note 1) 5Hz Maximum operating frequency Non-locking push type, Slotted locking type Manual operation With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust type

Valve specifications Pilot type Type of actuation Air Fluid Main valve Poppet Maximum operating pressure 0.7MPa Effective area 3mm Maximum vacuum pressure 84kPa Operating pressure 0.25 to 0.6MPa Supply pressure range 0.25 to 0.55MPa 5 to 50C Cv factor 0.17 Operating temperature range Polyethylene sintered body (30m) Electrical entry Plug connector Suction filter Maximum operating frequency 5Hz

Valve specifications Pilot type Type of actuation Air Fluid Main valve Poppet Maximum operating pressure 0.7MPa Effective area 3mm Maximum vacuum pressure 84kPa Operating pressure 0.25 to 0.6MPa Supply pressure range 0.25 to 0.55MPa 5 to 50C Cv factor 0.17 Operating temperature range Polyethylene sintered body (30m) Electrical entry Plug connector Suction filter Maximum operating frequency 5Hz

ZSE1-00ZSM1-0 Vacuum pressure switch 30 m PE (Polyethylene) Suction filter Valve Specifications How to operate Pilot type NBR poppet 3 mm2 Compact and lightweight 15.5 mm width, 400 g (full system) Main valve Effective area Cv factor Operating pressure range Electrical entry Max. operating frequency Voltage Power consumption 0.17 0.25 to 0.7 MPa Plug connector, Grommet (available on DC) 5Hz

Valve Solenoid Max.operating frequency 20Hz 5Hz Individual EXH Pilot valve EXH Not required Lubrication Non-locking push style/Locking slotted style Manual override 150/30 m/s2 Shock/Vibration resistance (2) Dust proof Enclosure 12V, 24V DC and 100V, 110V, 200V, 220V AC 10% of rated voltage Coil rated voltage Allowable voltage Class B or equivalent Coil insurance 1W DC (42mA), 0.5W DC (21mA

Valve Solenoid Max.operating frequency 20Hz 5Hz Individual EXH Pilot valve EXH Not required Lubrication Non-locking push style/Locking slotted style Manual override 150/30 m/s2 Shock/Vibration resistance (2) Dust proof Enclosure 12V, 24V DC and 100V, 110V, 200V, 220V AC 10% of rated voltage Coil rated voltage Allowable voltage Class B or equivalent Coil insurance 1W DC (42mA), 0.5W DC (21mA