Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Return Low Flow FLT. Potential cooling error may occur if the circulating fluid varies in concentration.

Calculating method-Take out the lower 1 byte of the total. eg.) Set temperature to 30 deg.C (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.

Calculating method-Take out the lower 1 byte of the total. eg.) Set temperature to 30 deg.C (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.

Calculating method -Take out the lower 1 byte of the total. eg.) Set temperature to 30oC (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Chemical Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.

Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Pump Breaker Trip FLT.

Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Pump Breaker Trip FLT. Potential cooling error may occur if the circulating fluid varies in concentration.

Actuators movement distance per pulse is obtained as below: actuators movement distance per pulse (mm/pls) actuators lead (mm) 1 / no. of encoders pulses2 lead length (mm) / 262144(pulse) eg.

Actuators move distance per pulse is obtained as below: actuators move distance per pulse (mm/pls) actuators lead (mm) 1 / no. of encoders pulses2 lead length (mm) / 4194304(pulse) eg.

VALVE, SX, 4/5 PORT SOLENOID VALVE, 26.53000 lb

Valve Mounting: 1 (Screw Mount Type), Filter: w/o Filter, Flow Rate/Operating Frequency: E (Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz), Lead Wire: G (300 mm)

Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: E (Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz), Lead Wire: G (300 mm)

Valve Mounting: 2 (Quick disconnect Type), Filter: w/o Filter, Flow Rate/Operating Frequency: E (Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz), Lead Wire: G (300 mm)

Valve Mounting: Quick disconnect Type, Filter: w/o Filter, Flow Rate/Operating Frequency: Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz, Lead Wire: 300 mm

Compatible Fluid: Air, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Multi-Port, Connection Type: Others, Operating Temperature Range(°C): -10~50, Driving Type: Linear Motion Type, Response Time: 1 msec. or Less, Acquired Standards: CE, Pipe opening type (details): Gasket mount, Voltage: 24 

Compatible Fluid: Air, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Multi-Port, Connection Type: Others, Operating Temperature Range(°C): -10~50, Driving Type: Linear Motion Type, Response Time: 1 msec. or Less, Acquired Standards: CE, Pipe opening type (details): Gasket mount, Voltage: 24 

Valve Mounting: 2 (Quick disconnect Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: M (Flow 150 L/min; Power 4W; Max. Op Frequency 150Hz), Lead Wire: G (300 mm)

Valve Mounting: 2 (Quick disconnect Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: A (Flow 50 L/min; Power 80W; Max. Op Frequency 1200Hz), Lead Wire: G (300 mm)

Valve Mounting: 2 (Quick disconnect Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: A (Flow 50 L/min; Power 80W; Max. Op Frequency 1200Hz), Lead Wire: H (500 mm)

Valve Mounting: 2 (Quick disconnect Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: J (Flow 150 L/min; Power 80W; Max. Op Frequency 600Hz), Lead Wire: J (1000 mm)

Valve Mounting: 2 (Quick disconnect Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: K (Flow 150 L/min; Power 40W; Max. Op Frequency 500Hz), Lead Wire: G (300 mm)