Positive common, Eg Serial Transmission. The lead wires are connected to the valve as shown below. Connect each to the power supply side. Negative common. The lead wires are connected to the valve as shown below. Connect each to the power supply side. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 !
(eg.) Pushing operation (eg.) Pushing operation [Speed/Position] Step Data "Positioning range" Pushing process Step Data "Pushing speed" Pushing force Load Speed Actuator Step Data "Speed" M Position Position of Pushing operation pushing start Motor In position Origin position Position of pushing start Step Data "Position" (2) Pushing operation fails (empty pushing).
Positive common, Eg Serial Transmission. The lead wires are connected to the valve as shown below. Connect each to the power supply side. Negative common. The lead wires are connected to the valve as shown below. Connect each to the power supply side. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 !
Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Return Low Flow FLT. Potential cooling error may occur if the circulating fluid varies in concentration.
Calculating method-Take out the lower 1 byte of the total. eg.) Set temperature to 30 deg.C (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.
Calculating method-Take out the lower 1 byte of the total. eg.) Set temperature to 30 deg.C (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.
Calculating method -Take out the lower 1 byte of the total. eg.) Set temperature to 30oC (without unit specified) STX 31H 33H 30H 30H 30H ETX 3FH 34H CR Total F4H eg.) Read Chemical Thermo-con internal sensor of unit No.2 SOH 32H 05H 32H 36H 39H CR Total 69H Note) Check sum is not ASCII code.
Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Pump Breaker Trip FLT.
Low concentration EG in the circulating fluid may cause system failure due to it being frozen in the system. High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Pump Breaker Trip FLT. Potential cooling error may occur if the circulating fluid varies in concentration.
Actuators movement distance per pulse is obtained as below: actuators movement distance per pulse (mm/pls) actuators lead (mm) 1 / no. of encoders pulses2 lead length (mm) / 262144(pulse) eg.
Actuators move distance per pulse is obtained as below: actuators move distance per pulse (mm/pls) actuators lead (mm) 1 / no. of encoders pulses2 lead length (mm) / 4194304(pulse) eg.
Valve Mounting: 1 (Screw Mount Type), Filter: w/o Filter, Flow Rate/Operating Frequency: E (Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz), Lead Wire: G (300 mm)
Valve Mounting: 1 (Screw Mount Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: E (Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz), Lead Wire: G (300 mm)
Valve Mounting: 2 (Quick disconnect Type), Filter: F (w/Filter), Flow Rate/Operating Frequency: E (Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz), Lead Wire: G (300 mm)
Valve Mounting: Quick disconnect Type, Filter: w/Filter, Flow Rate/Operating Frequency: Flow 100 L/min; Power 80W; Max. Op Frequency 650Hz, Lead Wire: 300 mm
Compatible Fluid: Air, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Multi-Port, Connection Type: Others, Operating Temperature Range(°C): -10~50, Driving Type: Linear Motion Type, Response Time: 1 msec. or Less, Acquired Standards: CE, Pipe opening type (details): Gasket mount, Voltage: 24
Compatible Fluid: Air, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Multi-Port, Connection Type: Others, Operating Temperature Range(°C): -10~50, Driving Type: Linear Motion Type, Response Time: 1 msec. or Less, Acquired Standards: CE, Pipe opening type (details): Gasket mount, Voltage: 24
Type: 000 (Lever Type Feedback), Pressure Gauge: 0 (None), Construction: 1 (w/Terminal Box), Accessories: EG (E+G)
Type: 000 (Lever Type Feedback), Pressure Gauge: 1 (0.2MPa), Construction: 0 (No Terminal Box), Accessories: EG (E+G)