-S41-M5 Type 10-SS5YJ3-S41-C4 Type 10-SS5YJ3-46-M5 Type 10-SS5YJ3-46-C4 1/8 M5 x 0.8 10-SYJ343 Type 10-SS5YJ3-S46-M5 Type 10-SS5YJ3-S46-C4 Note) The values are for individually operated 2 position type manifold bases.
-M5 10-SS5YJ3-S32-C4 Base mounted for internal pilot 10-SS5YJ3-41-M5 10-SS5YJ3-41-C4 10-SYJ343 1/8 10-SS5YJ3-S41-M5 10-SS5YJ3-S41-C4 10-SS5YJ3-46-M5 1/8 M5 x 0.8 10-SS5YJ3-46-C4 10-SYJ343 10-SS5YJ3-S46-M5 10-SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted
0.079 0.084 0.081 0.084 0.024 0.047 0.024 0.024 SS5YJ3-32-C4 SYJ33 1/8 SS5YJ3-S32-M5 SS5YJ3-S32-C4 SS5YJ3-41-M5 Base mounted for internal pilot SS5YJ3-41-C4 SYJ34 1/8 SS5YJ3-S41-M5 SS5YJ3-S41-C4 SS5YJ3-46-M5 SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 SS5YJ3-S46-M5 SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the
Order SS5YJ3 32 05 M5 Type 32 Type S32 ( ) Single solenoid coil is on same side as the A, B port.
Single solenoid coil is located on same side as the A, B port. 2 stations 02 : : R port M5 X 0.8 R port M5 X 0.8 20 stations 20 Applicable solenoid valve SYJ3l30-l SYJ3l33-l A/B port M3 X 0.5 P port P port A/B port M3 X 0.5 S M5 X 0.8 M5 X 0.8 32 Type (4 Port/Base mounted) Appilcable blank plate assembly How to Order SS5YJ3-32-05 -M5 32 Type S32 Type SYJ3000-21-2A Single solenoid coil is
-S32-C4 Type SS5YJ3-41-M5 Base mounted for internal pilot Type SS5YJ3-41-C4 SYJ34 1/8 Type SS5YJ3-S41-M5 Type SS5YJ3-S41-C4 Type SS5YJ3-46-M5 Type SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 Type SS5YJ3-S46-M5 Type SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted
-32-C4 SYJ33 1/8 SS5YJ3-S32-M5 SS5YJ3-S32-C4 SS5YJ3-41-M5 Base mounted for internal pilot SS5YJ3-41-C4 SYJ34 1/8 SS5YJ3-S41-M5 SS5YJ3-S41-C4 SS5YJ3-46-M5 SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 SS5YJ3-S46-M5 SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on
-20 Applicable manifold base (sub-plate) SS5YJ3-41 SS5YJ3-S41 SS5YJ3-46 SS5YJ3-S46 SS5YJ3-31 SS5YJ3-S31 SS5YJ3-32 SS5YJ3-S32 Manifold gasket Manifold gasket SS5YJ3-31 SS5YJ3-S31 SS5YJ3-32 SS5YJ3-S32 VJ3000-14-3 VJ3000-14-2 Note) Manifold gasket "VJ3000-14-2" can be used with the following manifold bases.
SS5YJ3-20,SS5YJ3-21P,SS5YJ3-21SA The 3 port valve can be used by simply sealing off the unused R port with rubber plug SYJ3000-33-1. Applicable solenoid valves SYJ312,SYJ312M,SYJ322,SYJ322M series SS5YJ3-31,-S31,SS5YJ3-32,-S32,SS5YJ3-32SA SS5YJ3-46,-S46,SS5YJ3-32P The 3 port valve can be used without modification. The A port of the valve will flow out of the B port of the manifold.
NH NC DTT UU TT UU Auto switch magnet holder M5 x 0.8 (Port) -X GA GA 2-M5 x 0.8 (Hexagon socket head plug) 2-M5 x 0.8 (Hexagon socket head plug) Cushion needle G G 20GB M5 x 0.8 (Hexagon socket head plug) N A M5 x 0.8 (Port) Data Z + Stroke M5 x 0.8 (WW) (WW) (Hexagon socket head plug) 2 x 2-J depth K M5 x 0.8 (Hexagon socket head plug) XX XX M5 x 0.8 (Port) VV VV 2-M5 x 0.8 (Hexagon socket
M6 01 02 03 04 M5 x 0.8 N46 x 1.0 PT1/8 PI1/4 PT3/8 Pr1/2 a a a a a a a a a a a a a a a a a a a a a a r ) a a a a a a a a The use of compact spacer with bracket reduces the tota assembled space.
-20SS5YJ3-21PSS5YJ3-21SA 3SYJ3000-33-1 R SYJ312SYJ312M SYJ300 3 SYJ322SYJ322M SYJ300 3 SS5YJ3-31-S31SS5YJ3-32-S32SS5YJ3-32SA SS5YJ3-46-S46SS5YJ3-32P SYJ3000-33-1 SYJ3000-33-1 3 R R 3AB SYJ314SYJ314M SYJ324SYJ324M SS5YJ3-41-S41 3SYJ3000-33-1 R 3AB SYJ314SYJ314M SYJ324 SYJ324M SS5YJ3-20 SS5YJ3-41 B3 A B3 A M1.7 : 0.12N.m 17 No.SYJ300-OMU0003 Assy SYJ32(R)(-Q)) (SYJ34(R)(-Q)) SYJ300
E 03 05 07 09 't't 5132" 1l4', 5/16' 3t8" 1/2" 6mm 8mm H , T , U , X , N 1 3 06 08 t0 1 2 1 6 32 i10-32 UNF Thread 3 5 I l t N P r H ' L . W , r .
-00-P How to Order Type 41 (5 Port/Base mounted) SS5YJ5 41 05 M5 Stations 02 2 stations P, R port thread type -+ -+ R port 1/8 : : R P Nil F N T Rc G NPT NPTF 20 20 stations A, B port M5 x 0.8 M5 M5 x 0.8 A, B port size P port 1/8 Applicable solenoid valve SYJ540SYJ543SYJ550SYJ553Type 42 (5 Port/Base mounted) How to Order SS5YJ5 42 05 C6 Stations Applicable blanking plate assembly SYJ5000
Program P1 P2 P3 P16 S1 S1 S1 S1 S2 S2 S2 S2 Step S32 S32 S32 S32 Following are CEU2s special feature: 1. Predictive Control & Learning Function (Allow High Repeatability and Precision, 0.5mm) With learning function, after every execution, brake point will be amended, according to the deviation of stopping position from setting position.
Program P1 P2 P3 P16 S1 S1 S1 S1 S2 S2 S2 S2 Step S32 S32 S32 S32 Following are CEU2s special feature: 1. Predictive Control & Learning Function (Allow High Repeatability and Precision. 0.5mm) With learning function, after every execution, brake point will be amended, according to the deviation of stopping position from setting position.
S32 S32 S32 S32 0.5mm) 1 2 2. 3. LCD 4.DIN 30mm 30mm 10 - 2-2 30mm No. 2-3 (1), (Err6), 1 ML2B25 15 ML2B32 19 ML2B40 24 2-4 5mm 5-10-15 5mm Err5 4.2 5 10 15 20 1.0 1.0 1.0 1.0 5.8 5mm30mm Err6: 20 30 100mm/sec :50cm :0.5MPa 11 - 3 3 3 3 ML2B+CEU2 NO 1 () () YES NO () YES NO YES YES NO YES NO YES YES NO NO NO YES A 12 - A 1.
VZA2221-M5 VZA2321-M5 VZA2421-M5 VZA2141-1-01 VZA2141-2-01 VZA2241-1-01 VZA2241-2-01 VZA2341-1-01 VZA2341-2-01 VZA2441-1-01 VZA2441-2-01 Single Double Closed center Exhaust center 0.60 0.60 0.56 0.60 0.43 0.43 0.15 0.20 0.15 0.15 0.13 0.15 0.59 0.59 0.59 0.59 0.30 0.30 0.22 0.22 0.15 0.15 0.14 0.14 Body ported Base mounted (With sub-plate) 2 position Body side M5 x 0.8 3 position M5 x 0.8