There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
C6: 6 (SMC) N7: 1/4" (SMC) Applicable tubing O.D. C6: 6 (SMC) C8: 8 (SMC) C10: 10 (SMC) N7: 1/4" (SMC) N9: 5/16" (SMC) N11: 3/8" (SMC) (11) (47.7) One-touch fitting [PE: Pilot EXH port] Applicable tubing O.D.
Specification SV2000 SV1000 Applicable series SV4000 SV3000 Manifold type Tie-rod base manifold 1(P: SUP)/3, 5(E: EXH) type Common SUP, EXH Valve stations (maximum) 20 stations Max. number of solenoids 32 points Port size 1(P)/3, 5(E) port C10, N11 C8, N9 C12, N11, 03 C12, N11 C4, C6, C8 N3, N7, N9 C3, C4, C6 N1, N3, N7 C8, C10, C12 N9, N11, 02, 03 C6, C8, C10 N7, N9, N11 4(A)/2(B) port Flow
For details, please contact SMC. 1-2-49 46 Series SV Dimensions: Series SV2000 for EX120 Dedicated Output Serial Wiring U D B C4, N3 C6, N7 C8, N9 Cassette base manifold: SS5V2-16S3D(S, R, RS) Stations When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
Type: Base for Manifolds, Communication Protocol: CC-Link Compatible, Output Format: -, Type: EX120 Compatible Cassette Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: -, Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port), Specification: External Pilot Specifications,
SI Unit: V (Mitsubishi CC-LINK System), Stations: 5 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: R (External Pilot), A, B Port: N7 (1/4" One-touch Fitting)
Specification SV2000 SV1000 SV4000 SV3000 Applicable series Manifold type Tie-rod base manifold 1(P: SUP)/3, 5(E: EXH) type Common SUP, EXH Valve stations (maximum) 20 stations Max. number of solenoids 32 points Port size 1(P)/3, 5(E) port C10, N11 C8, N9 C12, N11, 03 C12, N11 C4, C6, C8 N3, N7, N9 C3, C4, C6 N1, N3, N7 C8, C10, C12 N9, N11, 02, 03 C6, C8, C10 N7, N9, N11 4(A)/2(B) port Flow
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 8 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting)
SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting)
SI Unit: DeviceNet Omron CompoBus/D, Stations: 8 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 1/4" One-touch Fitting, Mounting Method: -
Enclosure: IP67, SI Unit: PROFINET - 32 Outputs - Connector M12, SI Unit Output Polarity: -COM, Stations: 8 Stations, P, E Port Entry: U Side 2~10 Stations, SUP/EXH Block Assembly: Internal Pilot, Built-in Silencer, A, B Port: 1/4" One-touch Fitting, Mounting: -, DIN Rail Option: -
SI Unit: DeviceNet, PROFIBUS-DP, EtherNet/IP, Stations: 8 Stations, SUP/EXH Block Mounting: U Side 2~10 Stations, Pilot: Internal Pilot, Built-in Silencer, A, B Port: 1/4" One-touch Fitting, Mounting Method: -
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: D-sub connector compatible tie-rod base manifold, Number of Inputs/Outputs: -, Connector: Upward Connector, Mounting Method: Direct mounting, Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port), Specification: Internal pilot
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: EX500, 128 Points Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: Direct mounting, Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port), Specification: Internal pilot,
Type: Base for Manifolds, Communication Protocol: DeviceNet / PROFIBUS DP / Ethernet/IP Compatible, Output Format: NPN (Positive Common), Type: EX500 64 Points Compatible Cassette Base Manifold, Number of Inputs/Outputs: 16 points (output), Connector: N/A, Mounting Method: -, Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8"
SI Unit: ZCN [ControlNet (IP40)], Input Block Stations: 43 [4 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting)
SI Unit: ZEN (EtherNet/IP), Input Block Stations: 53 [5 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting)
SI Unit: ZEN (EtherNet/IP), Input Block Stations: 23 (2 Stations/M8: 4 Inputs; 3 Pins), Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting)
SI Unit: ZEN (EtherNet/IP), Input Block Stations: 33 [3 Stations/M8: 4 Inputs (3 Pins)], Input Block COM: +COM, Stations: 8 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: N7 (1/4" One-touch Fitting)