There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
Barb fitting type (for rubber hose) Barb fitting type (for rubber hose) Model Hose nominal Model Hose nominal KK130P-07B -09B -11B -13B KK130S-07B -09B -11B -13B 6 (1/4") 6 (1/4") 8 (1/4") 8 (1/4") 9 (3/8") 9 (3/8") 12 (1/2") 12 (1/2") The figures in ( ) indicate the internal diameter of the applicable hose.
Part no. 1/4" KK13S-07B 1/4" KK13P-07B 5/16" 09B 5/16" -09B 3/8" -11B 3/8" -11B 1/2" -13B 1/2" -13B 10 S Couplers Series KK13 M a n u Specifications Fluid Air Note 1) Operating pressure range 0 to 1.5MPa Proof pressure 2MPa Ambient and fluid temperature 5 to 60C Plating Nickel plated external metal parts Note 1) Cannot be used with water.
Part no. 1/4" KK13S-07B 1/4" KK13P-07B 5/16" 09B 5/16" -09B 3/8" -11B 3/8" -11B 1/2" -13B 1/2" -13B 10 S Couplers Series KK13 Manufactured by Rectus Specifications Fluid Air Note 1) Operating pressure range 0 to 1.5MPa Proof pressure 2MPa Ambient and fluid temperature 5 to 60C Plating Nickel plated external metal parts Note 1) Cannot be used with water.
C4: 4 (SMC) N3: 5/32" (SMC) One-touch fitting [X: External pilot port] Applicable tubing O.D. C4: 4 (SMC) N3: 5/32" (SMC) (9.5) (43.9) One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.
Contact SMC for details. 37 37 Series SV EX120 Dedicated Output Serial Wiring Dimensions: Series SV2000 for EX120 Dedicated Output Serial Wiring 1in = 25.4mm C4, N3 C6, N7 C8, N9 Cassette base manifold: SS5V2-16S3D Stations (S, R, RS) U D B When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
For details, please contact SMC. 1-2-49 46 Series SV Dimensions: Series SV2000 for EX120 Dedicated Output Serial Wiring U D B C4, N3 C6, N7 C8, N9 Cassette base manifold: SS5V2-16S3D(S, R, RS) Stations When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
SMC SV2000-50-2A-C4 manifold block assy, SS5V2 MANIFOLD SV2000*** $33.72 Add to Quote Add To Cart Add to Cart SMC SV2000-51D-11A-00 sup/exh block assy int, SS5V2 MANIFOLD SV2000
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Side Direction, Stations: 9 Stations, SUP/EXH Block Mounting: Both Sides 2~18 Stations, Pilot: Internal Pilot, A, B Port: ø4 One-touch Fitting
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 9 Stations, SUP/EXH Block Mounting: B (Both Sides 2~18 Stations), Pilot: Internal Pilot, A, B Port: C4 (ø4 One-touch Fitting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 9 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N3 (5/32" One-touch Fitting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 9 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting)
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Side Direction, Stations: 9 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, A, B Port: 5/32" One-touch Fitting
Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Side Direction, Stations: 9 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, A, B Port: 1/4" One-touch Fitting
Specification SV1000 SV2000 Applicable series Stacking type cassette base manifold Manifold type Common SUP, EXH 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) 18 stations 20 stations Max. number of solenoids 18 points 26 points 1(P)/3, 5 (E) port C8, N9 C10, N11 Port size C3, C4, C6 N1, N3, N7 C4, C6, C8 N3, N7, N9 4(A)/2(B) port Flow Characteristics Flow characteristics Port size
Dimensions Single unit Manifold 2 x C4, C6 C4: 4 one-touch fitting C6: 6 one-touch fitting 2 x C4, C6 C4: 4 one-touch fitting C6: 6 one-touch fitting Mounting hole for M3 Mounting hole for M2.5 Manual override for residual pressure exhaust Manual override for residual pressure exhaust DIN rail clamping screw Stations12 3 D side U side 2 x C3, C4, C6, M5 C3: 3.2 one-touch fitting C4: 4 one-touch
Note) Based on JIS B 8375-1981 (Supply pressure: 0.5 MPa) Dimensions Single unit Manifold 2n x C4, C6 C4: 4 one-touch fitting C6: 6 one-touch fitting 2 x C4, C6 C4: 4 one-touch fitting C6: 6 one-touch fitting M3 mounting hole P = 11 M2.5 mounting hole Residual pressure release manual override DIN rail clamp screw Residual pressure release manual override Stations 1 2 3 n D side U side
C4: 4 (SMC) N3: 5/32" (SMC) One-touch fitting [X: External pilot port] Applicable tube O.D. C4: 4 (SMC) N3: 5/32" (SMC) (9.5) (43.9) One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 8 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: C4 (ø4 One-touch Fitting)